Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > Industrial Relays and Timers > NEMA Heavy-Duty Industrial Relays > Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay
Bulletin 700-P, 700-PH, and 700-PK Heavy-Duty Relay
Product Selection| Build a Catalog Number |
Electrically Held Relays
Bulletin 700-P Standard Contact Cartridge⋆
AC-Operated Relays
| Contacts | Contact Arrangement and Markings |
Open Type Relay Rail Mount♦ |
||
| N.O. | N.C. | Cat. No. | ||
|
2 | — |
|
700-P200Ä |
| 4 | — | 700-P400Ä | ||
| 6 | — |
|
700-P600Ä | |
| 8 | — | 700-P800Ä | ||
| 10 | — |
|
700-P1000Ä | |
| 12 | — | 700-P1200Ä | ||
ÄAC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-P200Ä becomes Cat. No. 700-P200A48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| Hz | 24 | 48 | 110 | 110-115 | 115-120 | 120 | 127 | 200-208 | 220-230 | 230-240 | 277 | 347 | 380 | 415 | 440-480 | 460-480 | 500 | 575-600 |
| 50 | B24 | B48 | A1♠ | B11∇ | — | — | B27 | — | B22 | B2 | — | — | B3 | B41 | B44 | — | B50 | — |
| 60 | A24 | A48 | — | — | A1♠ | B11∇ | — | A20 | A22 | A2 | A27 | A35 | — | — | — | A4 | — | A6 |
| ♠ Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. | ||||||||||||||||||
| ∇ Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz. | ||||||||||||||||||
DC-Operated Relays
ÄDC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-P200Ä becomes Cat. No. 700DC-P200Z48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| 6 | 12 | 18 | 24 | 32 | 48 | 64 | 72 | 90 | 115-125 | 230-250 | 500-550 | 575-600 |
| Z06 | Z12 | Z18 | Z24 | Z32 | Z48 | Z64 | Z72 | Z90 | Z1 | Z2 | Z5 | Z6 |
| ♠ Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. | ||||||||||||
| ∇ Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz. | ||||||||||||
| ⋆ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. | ||||||||||||
| Overlap contacts: To order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O. contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P161. | ||||||||||||
| § Location of contacts in 2-pole relays. | ||||||||||||
| ♣ Location of contacts in 6-pole relays: 4-pole relay plus the two contacts indicated. | ||||||||||||
| ∆ Location of contacts in 10-pole relays: 8-pole relay plus the two contacts indicated. | ||||||||||||
| ♦ See NEMA Type 1 and Type 4/4X enclosures for field installation. | ||||||||||||
Electrically Held Relays
Bulletin 700-PK Master Contact Cartridges⋆
AC-Operated Relays
| Contacts | Contact Arrangement and Markings |
Type 1♦ General Purpose |
||
| N.O. | N.C. | Cat. No. | ||
|
2 | — |
|
700-PK201Ä |
| 4 | — | 700-PK401Ä | ||
| 6 | — |
|
700-PK601Ä | |
| 8 | — | 700-PK801Ä | ||
| 10 | — |
|
700-PK1001Ä | |
| 12 | — | 700-PK1201Ä | ||
ÄAC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-PK200Ä becomes Cat. No.700-PK200A48 for 48V 60 Hz. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| Hz | 24 | 48 | 110 | 110-115 | 115-120 | 120 | 127 | 200-208 | 220-230 | 230-240 | 277 | 347 | 380 | 415 | 440-480 | 460-480 | 500 | 575-600 |
| 50 | B24 | B48 | A1♠ | B11∇ | — | — | B27 | — | B22 | B2 | — | — | B3 | B41 | B44 | — | B50 | — |
| 60 | A24 | A48 | — | — | A1♠ | B11∇ | — | A20 | A22 | A2 | A27 | A35 | — | — | — | A4 | — | A6 |
| ♠ Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. | ||||||||||||||||||
| ∇ Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz. | ||||||||||||||||||
DC-Operated Relays
ÄDC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PK200Ä becomes Cat. No. 700DC-PK200Z12 for 12V DC. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| 6 | 12 | 18 | 24 | 32 | 48 | 64 | 72 | 90 | 115-125 | 230-250 | 500-550 | 575-600 |
| Z06 | Z12 | Z18 | Z24 | Z32 | Z48 | Z64 | Z72 | Z90 | Z1 | Z2 | Z5 | Z6 |
Electrically Held Relays — Typical Wiring Diagrams
|
|
Electrically Held Relays
Bulletin 700-PH 35 A Tandem Contact Cartridges⋆
AC-Operated Relays
|
Contacts | Contact Arrangement and Markings |
Open Type Relay Rail Mount♦ |
|
| N.O. | N.C. | Cat. No. | ||
| 1 | — |
|
700-PH100Ä | |
| 2 | — | 700-PH200Ä | ||
| 3 | — |
|
700-PH300Ä | |
| 4 | — | 700-PH400Ä | ||
| 5 | — |
|
700-PH500Ä | |
| Cat. No. 700-PH200 | 6 | — | 700-PH600Ä | |
ÄAC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-PH100Ä becomes Cat. No. 700-PH100A48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| Hz | 24 | 48 | 110 | 110-115 | 115-120 | 120 | 127 | 200-208 | 220-230 | 230-240 | 277 | 347 | 380 | 415 | 440-480 | 460-480 | 500 | 575-600 |
| 50 | B24 | B48 | A1♠ | B11∇ | — | — | B27 | — | B22 | B2 | — | — | B3 | B41 | B44 | — | B50 | — |
| 60 | A24 | A48 | — | — | A1♠ | B11∇ | — | A20 | A22 | A2 | A27 | A35 | — | — | — | A4 | — | A6 |
| ♠ Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. | ||||||||||||||||||
| ∇ Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz. | ||||||||||||||||||
DC-Operated Relays
ÄDC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-PH200Ä becomes Cat. No. 700DC-PH200Z12. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
| 6 | 12 | 18 | 24 | 32 | 48 | 64 | 72 | 90 | 115-125 | 230-250 | 500-550 | 575-600 |
| Z06 | Z12 | Z18 | Z24 | Z32 | Z48 | Z64 | Z72 | Z90 | Z1 | Z2 | Z5 | Z6 |
| ⋆ Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts. | ||||||||||||
| Location of contacts in 1-pole relays. | ||||||||||||
| § Location of contacts in 3-pole relays: 2-pole relay plus the contact indicated. | ||||||||||||
| ♣ Location of contacts in 5-pole relays: 4-pole relay plus the contact indicated. | ||||||||||||