| International Symbol for Mechanically Linked Contacts
|
|
|
Description
|
No. of N.O. Contacts
|
No. of N.C. Contacts
|
Continuous Carrying Current [A]
|
Arrangement
|
Cat. No.
|
| Second Deck (2-pole)
|
2
|
—
|
10
|
|
700-PB20
|
| 2
|
—
|
20
|
700-PKB20
|
| Second Deck (4-pole)
|
4
|
—
|
10
|
|
700-PB40
|
Second Deck Cat. No. 700-PB40
|
4
|
—
|
20
|
700-PKB40
|
|
Third Deck (2-pole)
|
2
|
—
|
10
|
|
700-PC20
|
| 2
|
—
|
20
|
700-PKC20
|
| Third Deck (4-pole)
|
4
|
—
|
10
|
|
700-PC40
|
Third Deck Cat. No. 700-PC40
|
4
|
—
|
20
|
700-PKC40
|
|
|
|
Description
|
Continuous Carrying Current[A]
|
Arrangement
|
Pkg. Quantity
|
Cat. No.
|
Standard Contact Cartridge AC Rating NEMA A600 DC Rating NEMA P600
|
10
|
|
1
|
700-CP1
|
Standard Contact Cartridge Cat. No. 700-CP1, -CP11Z
|
Overlap Contact Cartridges Overlapping Used in pairs. N.O. contact closes before N.C. contact opens on pick-up and vice versa on drop-out.∆
|
AC Rating NEMA A600
|
10
|
|
2
|
700-CP11Z
|
|
DC Rating NEMA P150 125V DC, 138 VA Make and Break
|
5
|
Master Contact Cartridge Cat. No. 700-CPM
|
Master Contact Cartridge AC Rating Twice NEMA A600 DC Rating Twice NEMA P600
|
20
|
|
1
|
700-CPM
|
|
Logic Reed Cartridge for Low Energy Circuits 150V AC 500 mA 25 VA Max. 30V DC 200 mA 6W Max.⋆
|
Maximum 150V AC
|
500 mA
|
|
1
|
700-CPR
|
Logic Reed Cartridge Cat. No. 700-CPR
|
Maximum 30V DC
|
200 mA
|
|
Safety Contact Cartridge Cartridge meeting IEC 947-5 Note: Use this cartridge when full compliance to IEC 947-5 is required. 700-P relays equipped with CPS cartridges fully meet the IEC 947-5 spec for mechanically linked contacts.
|
10
|
|
1
|
700-CPS
|
Safety Contact Cartridge Cat. No. 700-CMS
|
20
|
700-CMS
|
|
|
| ∆ Not Direct Drive.
|
| ⋆ The 700-CPR Logic Reed cartridge must be installed only in the 2nd deck (B1X - B4X, B1Y - B4Y position) or 3rd deck (C1X - C4X, C1Y - C4Y position) of the Bulletin 700 Type P relay. It is not recommended that the 700-CPR cartridge be installed in the single deck (A1X - A4X, A1Y - A4Y position) because this may lead to improper operation.
|
|
|
Description
|
Continuous Carrying Current [A]
|
Arrangement
|
Timing Range
|
Cat. No.
|
|
Self-Contained Potentiometer
On-Delay
|
5
|
|
0.1…2
|
700-PSAA1
|
| 0.4…8
|
700-PSBA1
|
| 1.5…30
|
700-PSCA1
|
| 6…120
|
700-PSDA1
|
| Off-Delay
|
0.1…2
|
700-PSPA1
|
| 0.4…8
|
700-PSRA1
|
| 1.5…30
|
700-PSTA1
|
| 6…120
|
700-PSUA1
|
External Potentiometer
On-Delay
|
5
|
|
0.1…2 s
|
700-PSRAA1
|
| 0.4…8 s
|
700-PSRBA1
|
| 1.5…30 s
|
700-PSRCA1
|
| 6…120 s
|
700-PSRDA1
|
| Off-Delay
|
0.1…2 s
|
700-PSRPA1
|
| 0.4…8 s
|
700-PSRRA1
|
| 1.5…30 s
|
700-PSRTA1
|
| 6…120 s
|
700-PSRUA1
|
|
|
|
Description
|
Continuous Carrying Current [A]
|
Arrangement
|
Timing Range
|
Open Type Without Enclosure
|
| Operating Mode
|
No. of N.O. Contacts
|
No. of N.C. Contacts
|
Cat. No.
|
On-Delay Off-Delay
|
1
|
1
|
10
|
|
0.1…60 s
|
700-PT
|
| Pneumatic Time-Delay
|
20
|
700-PKT
|
|
|
| ⋆ Mounts on 4-pole Bulletin 700-P or -PK relay or 2-pole Bulletin 700-PH relay.
|
| Maximum time may be 50% greater and the minimum time may be 50% less than the value specified.
|
|
|
Description
|
Arrangement
|
Continuous Carrying Current [A]
|
Cat. No.
|
|
AC-Operated Latch Units
|
|
No cartridge
|
700-PLLÄ
|
| 10
|
700-PLL11Ä
|
| 20
|
700-PKLL11Ä
|
| DC-Operated Latch Units
|
|
No cartridge
|
700DC-PLLÄ
|
| 10
|
700DC-PLL10Ä
|
| 20
|
700DC-PKLL10Ä
|
|
|
| Hz
|
24
|
48
|
110
|
110-115
|
115-120
|
120
|
127
|
200-208
|
220-230
|
230-240
|
277
|
347
|
380
|
415
|
440-480
|
460-480
|
500
|
575-600
|
| 50
|
B24
|
B48
|
A1⋆
|
B11
|
—
|
—
|
B27
|
—
|
B22
|
B2
|
—
|
—
|
B3
|
B41
|
B44
|
—
|
B50
|
—
|
| 60
|
A24
|
A48
|
—
|
—
|
A1⋆
|
B11
|
—
|
A20
|
A22
|
A2
|
A27
|
A35
|
—
|
—
|
—
|
A4
|
—
|
A6
|
|
|
| ⋆ Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz.
|
| Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
|
|
Description
|
Relays per Strip
|
Pkg. Quantity
|
Cat. No.
|
Relay Rail Simplifies panel layout. These indexed strips are easily cut to the required length and bolted, riveted, or spot-welded in place. Relays are installed adjacent to one another on the mounting strip with the captive mounting screws provided. Rows of relays on Relay Rail form their own wiring trough. Can be used with the following relays: 700P, 700-PK, 700PH, 700S-P, 700N, 700-R, 700-RTC
|
4
|
5
|
700-MP4
|
| 8
|
5
|
700-MP8
|
| 12
|
5
|
700-MP12
|
Mounting Strip Cat. No. 700-MP4
|
16
|
5
|
700-MP16
|
|
DIN Rail Adapter Can be used with the following relays: Bulletin 700P, 700-PK, 700-PH, 700S-P, 700-N, 700-R, 700-RTC
|
1
|
700-DRA
|
| Cat. No. 700-DRA
|
|
DIN (#3) symmetrical hat rail 35 x 7.5 x 1 m
|
10
|
199-DR1
|
| 199-DR1
|
|
Type 1 Enclosure — Use for all Bulletin 700-P, -PH, and -PK relays except 10- and 12-pole DC relays or 5- and 6-pole DC Bulletin 700-PH relays.
|
1
|
700-N31
|
| Type 4/4X Enclosure — For 2- and 4-pole Bulletin 700-P, -PH, -N, and -R relays and 2-pole Bulletin 700-PH relays.
|
1
|
700-N39
|
| Cat. No. 700-N31
|
Type 7 & 9 Enclosure — For 2- and 4-pole Bulletin 700-P, -PK, -N, and -R relays and 2-pole Bulletin 700-PH relays. 1 conduit hub; top and bottom.
|
1
|
700-N33
|
|
|
|
|
Description
|
Pkg. Quantity
|
Cat. No.
|
|
Surge Suppressors (RC Circuit) — Surge suppressors reduce the high transient voltages generated when the coil circuit is opened. These suppressors can be used with Bulletin 700-P, -PH, -PK, and -N relays, and other electromechanical devices. They contain a resistor and capacitor. Maximum ratings: 150V, AC or DC, 35 VA. Cat. No. 700-N5 requires 1 in. additional depth of enclosure.
|
Mounting behind relay
|
1
|
700-N5
|
Surge Suppressor Cat. No. 700-N5
|
|
Mounting on coil terminal
|
1
|
700-N24
|
Surge Suppressor Cat. No. 700-N24
|
|
Surge Suppressor When the circuit to a DC operating coil is opened, the inductive energy stored in the coil can generate very high transient voltages. With the addition of the appropriate surge suppressor, the stored energy is absorbed and dissipated limiting the voltage spikes. A surge suppressor is not required with AC 700-R or -RM relays because the AC operating coil transients are suppressed by a full wave rectifier connected to the coil.
|
24…48V AC/DC
|
1
|
199-FSMA9
|
| 50…120V AC/DC
|
1
|
199-FSMA10
|
| 130…250V AC/DC
|
1
|
199-FSMA11
|
Surge Suppressor Cat. No. 199-FSMA1
|
Diode Surge Suppressor — for 6…300V DC voltage coils. Used on Bulletin 700-P, -PH, -PK, -N, -F, and -R relays.
|
1
|
199-FSMZ-1
|
|
35 A Jumper Kit CSA Approved, UL Listed This 35 A Jumper Kit can be used with any Bulletin 700-P and -PK AC or DC relay, Time-Delay relay or Latch Unit equipped with 20 A Master Cartridges. It does not require any additional panel space. Jumper Kit terminals are designed for one #8 AWG wire or two #10 AWG wires. When connecting the two 20 A Master Cartridges in parallel, it is important that they be the same configuration (Normally Open or Normally Closed). Jumpers can be added to any contact cartridge location on a relay except the two center poles because of the wide spacing. An adhesive label is included with each kit listing the contact ratings.
|
1
|
700-CPH
|
35 A Jumper Kit Cat. No. 700-CPH
|
|
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) For connection between a middle pole and an outer pole on the left or right side of the relay.
|
Jumper For outer poles
|
50
|
700-N3
|
Jumper Cat. No. 700-N3
|
Jumper Cat. No. 700-N4
|
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) For connection between two middle poles.
|
Jumper For middle poles
|
700-N4
|
|
Check Out Tool — Mechanically maintains the Bulletin 700-P, -PH, or -PK relay in the energized position for troubleshooting purposes.
|
1
|
700-N23
|
Check Out Tool Cat. No. 700-N23
|
Adapter Plate — Simplified relay conversion. Allows you to use the existing mounting holes when you replace a Bulletin 700-B, -BR, -BX, or -D relay with a Bulletin 700-P, -PH, or -PK relay.
|
700-N34
|
|
Protective Cover — For 700-PT Timing Adjustment Knob. Helps prevent tampering with time setting.
|
5
|
700-N38
|
|
|
|
|
Description
|
Pkg. Quantity
|
Cat. No.
|
|
Top Covers (Covering Top Level Contact Screws)
|
|
|
| IP2X Top Cover for 700-P, (AC Standard Relays)
|
5
|
700-PFSACT
|
| IP2X Top Cover for 700-P, (DC Standard Relays)
|
5
|
700-PFSDCT
|
| IP2X Top Cover for 700PK, (AC Master Control Relays)
|
5
|
700-PFSAPKT
|
| IP2X Top Cover for 700PK, (DC Master Control Relays)
|
5
|
700-PFSDPKT
|
| Timer Top Cover Kit, (for Relays with Pneumatic Latch Attachment)
|
5
|
700-PFSTC
|
| Timer Top Cover Kit (for Relays with Mechanical Latch Attachment)
|
5
|
700-PFSLCK
|
| Timer Top Cover Kit, (for Master Cont. Relays with Pneumatic Timer)
|
5
|
700-PFSKTC
|
| Latch Top Cover Kit (for Master Cont. Relays with Mechanical Latch)
|
5
|
700-PFSKLCK
|
| Deck Covers (Covering all terminals not on top deck, only for multi-deck relays)
|
| IP2X Deck Cover for all AC & DC Relays in the 700P Range
|
10
|
700-PFSDEK
|
| Coil Covers
|
| IP2X Coil Cover for all AC Relays in the 700P Range
|
5
|
700-PFSACC
|
| IP2X Coil Cover for all DC Relays in the 700P Range
|
5
|
700-PFSDCC
|
|
|