Bulletin 700-PS
| Supply Voltage | 110…120V AC, 50/60 Hz |
| Power Requirement | 4 VA, 2.5 W |
| Output Contact Ratings | NEMA B600 and P300. See pub. 700-SG003_-EN-P. |
| Operating Temperature Range | 20…+60 °C ambient (4…+140 °F) |
| Reset Time | 20 ms |
| Repeat Accuracy, Constant Voltage and Temperature | ±2% of setting or ±0.004 s, whichever is greater |
| Standards | NEMA B600, NEMA P300 |
| Certifications | UL Listed, Class I, Division 2, Groups A, B, C, and D, CSA Certified |
Operation
The timer must be energized continuously (L1-L2). ON-Delay: When the initiating contact closes, timing begins. At time-out, the output contact closes. OFF-Delay: When the initiating contact closes, the output contact closes instantly. When the initiating contact re-opens, timing begins. At time-out, the output contact re-opens.
Typical Wiring Diagram¬
|
Attention — To avoid damage to timer, do not switch any load in addition to timing relay at terminals S1S2. Do not apply an external voltage to terminals S1S2.