NEMA Heavy-Duty Industrial Relays

Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > Industrial Relays and Timers > NEMA Heavy-Duty Industrial Relays > Bulletin 700-R -RM Sealed Switch Relays

Bulletin 700-R -RM Sealed Switch Relays

Introduction Standards Compliance and Certifications Product Selection Accessories Specifications Approximate Dimensions
Build a Catalog Number


No.
of
Poles
Electrically Held
Contacts Contact Arrangement
and Markings‡ 
AC-Operated Relay Only DC-Operated Relay Only
Open Type Open Type
N.O. N.C. Cat. No. Cat. No.
0 0 0 Relay without Contact 700-R000Ä 700DC-R000Ä
2 2 0 Click to enlarge - 700RRM-230-1 700-R200Ä 700DC-R200Ä
1 1 700-R110Ä 700DC-R110Ä
0 2 700-R020Ä 700DC-R020Ä
4 4 0 700-R400Ä 700DC-R400Ä
3 1 700-R310Ä 700DC-R310Ä
2 2 700-R220Ä 700DC-R220Ä
1 3 700-R130Ä 700DC-R130Ä
0 4 700-R040Ä 700DC-R040Ä
6 6 0 Click to enlarge - 700RRM-230-2 700-R600Ä 700DC-R600Ä
5 1 700-R510Ä 700DC-R510Ä
4 2 700-R420Ä 700DC-R420Ä
3 3 700-R330Ä 700DC-R330Ä
2 4 700-R240Ä 700DC-R240Ä
1 5 700-R150Ä 700DC-R150Ä
0 6 700-R060Ä 700DC-R060Ä
8 8 0 700-R800Ä 700DC-R800Ä
7 1 700-R710Ä 700DC-R710Ä
6 2 700-R620Ä 700DC-R620Ä
5 3 700-R530Ä 700DC-R530Ä
4 4 700-R440Ä 700DC-R440Ä
3 5 700-R350Ä 700DC-R350Ä
2 6 700-R260Ä 700DC-R260Ä
1 7 700-R170Ä 700DC-R170Ä
0 8 700-R080Ä 700DC-R080Ä
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-R000Ä becomes Cat. No. 700-R000A24.

Type of Relay [V] Coil Volts
24 48 110 115-125 120 220 230-250 240
AC 25, 50, 60 Hz A1 A2
A24 A1 A2
DC Z24 Z48 Z1 Z2
  
‡ Arrangement displays all N.O. contacts.
♣ Polarity must be observed for DC voltage (700 DC) relays.
∆ Location of contacts in 2-pole relays.
♦ Location of contacts in 6-pole relays.

No.
of
Poles
Magnetic Latch
Contacts Contact Arrangement
and Markings ‡ 
AC-Operated Relay Only DC-Operated Relay Only
Open Type Open Type
N.O. N.C. Cat. No. Cat. No.
0 0 0 Relay without Contact 700-RM000Ä 700DC-RM000Ä
2 2 0 Click to enlarge - 700RRM-231-1 700-RM200Ä 700DC-RM200Ä
1 1 700-RM110Ä 700DC-RM110Ä
0 2 700-RM020Ä 700DC-RM020Ä
4 4 0 700-RM400Ä 700DC-RM400Ä
3 1 700-RM310Ä 700DC-RM310Ä
2 2 700-RM220Ä 700DC-RM220Ä
1 3 700-RM130Ä 700DC-RM130Ä
0 4 700-RM040Ä 700DC-RM040Ä
6 6 0 Click to enlarge - 700RRM-231-2 700-RM600Ä 700DC-RM600Ä
5 1 700-RM510Ä 700DC-RM510Ä
4 2 700-RM420Ä 700DC-RM420Ä
3 3 700-RM330Ä 700DC-RM330Ä
2 4 700-RM240Ä 700DC-RM240Ä
1 5 700-RM150Ä 700DC-RM150Ä
0 6 700-RM060Ä 700DC-RM060Ä
8 8 0 700-RM800Ä 700DC-RM800Ä
7 1 700-RM710Ä 700DC-RM710Ä
6 2 700-RM620Ä 700DC-RM620Ä
5 3 700-RM530Ä 700DC-RM530Ä
4 4 700-RM440Ä 700DC-RM440Ä
3 5 700-RM350Ä 700DC-RM350Ä
2 6 700-RM260Ä 700DC-RM260Ä
1 7 700-RM170Ä 700DC-RM170Ä
0 8 700-RM080Ä 700DC-RM080Ä
  

Ä Coil Voltage Code

The Cat. No. as listed is incomplete. Select a voltage code from the table below to complete the Cat. No. Example: Cat. No. 700-RM000Ä becomes Cat. No. 700-RM000A24. For other coil voltages, contact your local Rockwell Automation sales office or Allen-Bradley distributor.

Type of Relay [V] Coil Volts
24 48 110 115-125 120 220 230-250 240
AC 25, 50, 60 Hz A1 A2
A24 A1 A2
DC Z24 Z48 Z1 Z2
  
‡ Arrangement displays all N.O. contacts.
♣ Location of contacts in 6-pole relays.
∆ Polarity must be observed for DC voltage (700 DC) relays.
♦ Location of contacts in 2-pole relays.