Bulletin 700-N Industrial Relay
| Introduction | Standards Compliance and Certifications | Product Selection | Accessories | Specifications | Approximate Dimensions |
| Build a Catalog Number |
AC-Operated Relays
| Contacts⋆ | Contact Arrangement | Open Type | ||
| N.O. | N.C. | Cat. No. | ||
|
4 | — |
|
700-N400Ä |
| Type NM Relay 2 Poles§ |
2 | — |
|
700-NM200Ä |
Ä AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-N200Ä becomes Cat. No. 700-N200A24 for 24V 60 Hz. For other coil voltages, contact your local Rockwell Automation sales office or Allen-Bradley distributor.
Operating Coils
|
Coil Voltage | Bulletin 700-N Relay 2-…8-Pole | |
| 60 Hz | 50 Hz | ||
| 24 | 84AB27 | 84AB28 | |
| 110 | 84AB01 | 84AB86 | |
| 120 | 84AB86 | — | |
| 208 | 84AB113 | — | |
| Bulletin 700-N Operating Coil |
220 | 84AB06 | 84AB83 |
| 240 | 84AB83 | — | |
AC-Operated Relays with Pneumatic Timing Unit⋆ §
|
Description | Instantaneous Contacts |
Contact Arrangement | Open Type | |
| N.O. | N.C. | Cat. No. | |||
| Electrically Held AC Relay | 2 | — |
|
700-NT200Ä | |
| 4 | — |
|
700-NT400Ä | ||
Ä AC Voltage Suffix Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-NT200 Ä becomes Cat. No. 700-NT200A24. For other coil voltages, contact your local Allen-Bradley Distributor.
| Voltage | 24V | 32V | 48V | 64V | 110V | 115…125V | 120V | 208V | 220V | 230…250V | 240V |
| 50 Hz | B24 | B32 | B48 | B64 | A1 | — | — | B20 | A2 | — | — |
| 60 Hz | A24 | A32 | A48 | A64 | — | — | A1 | A20 | — | — | A2 |
| ⋆ NORMALLY CLOSED CONTACTS: Listed relays are supplied with all contacts normally open. These contacts can be readily converted to normally closed in the field. Relays having combinations of normally open and normally closed contacts can be supplied. | |||||||||||
| OVERLAP CONTACTS: Overlap contacts (normally open contact closes before the normally closed contact opens) can be supplied. See Accessories for information on kits for field installation of overlap contact cartridges. | |||||||||||
| § BIFURCATED CONTACTS: To order a relay with bifurcated contacts, add the letter B after the letter T in the Cat. No. Example: Cat. No. 700-NT200A1 becomes Cat. No. 700-NTB200A1. | |||||||||||
Bulletin 700-NT Pneumatic Timing Unit
Bulletin 852S Solid-State Timing Unit for Mounting on Bulletin 700-N Relays⋆
(Supplied as On-Delay. Easily Converted to Off-Delay Mode) Input: 110V/50 Hz, 120V/60 Hz; Output: NEMA B300, Sealed Contacts
| Timing Unit with Self-Contained Potentiometer | ||
| Minimum Time [s] | Minimum Time [s] | Cat. No. |
| 0.1 | 5.0 | 852S-NSA |
| 0.5 | 30.0 | 852S-NSB |
| 1.0 | 60.0 | 852S-NSC |
| Timing Unit Only | External Potentiometer | ||||
| Minimum Time [s] | Maximum Time [s] | Cat. No. | Resistance | Cat. No. | |
| 0.1 | 0.21 | | 852S-A | 15 kW | 800T-U34 |
| 0.35 | 25 kW | 800T-U37 | |||
| 0.70 | 50 kW | 800T-U41 | |||
| 1.10 | 75 kW | 800T-U46 | |||
| 1.50 | 100 kW | 800T-U49 | |||
| 2.10 | 150 kW | 800T-U50 | |||
| 5.6 | 400 kW | 800T-U54 | |||
| 7.0 | 500 kW | 800T-U55 | |||
| 14.0 | 1 MW | 800T-U57 | |||
| 29.0 | 2 MW | 800T-U59 | |||
| 1.0 | 2.0 | 852S-C | 50 kW | 800T-U41 | |
| 4.0 | 100 kW | 800T-U49 | |||
| 8.0 | 200 kW | 800T-U51 | |||
| 16.0 | 400 kW | 800T-U54 | |||
| 32.0 | 800 kW | 800T-U56 | |||
| 40.0 | 1 MW | 800T-U57 | |||
| 80.0 | 2 MW | 800T-U59 | |||
| 120.0 | 3 MW | 800T-U62 | |||
| 160.0 | 4 MW | 800T-U64 | |||
| ⋆ The maximium time is fixed by component characteristics and may be up to 70% greater than listed | |||||
| These timing relays require an external potentiometer. To order an external potentiometer, refer to right side of table. | |||||