| Product Overview |
|
Bulletin 700-CF — Control Relay
- IEC industrial relays
- Mechanically linked contact performance per IEC 60947-5-1
- Gold plated, bifurcated version for low level switching applications
- Master control relay version rated 15 A (AC-15)
- Solid-state and pneumatic timing modules
- 4-…10 Poles
Standards Compliance
-
UL 508
CSA C22.2 No. 14
EN/IEC 60947-1, -5-1
Meets the material restrictions for European Directive 2002/95/EC - EU-RoHS
Certifications
-
cULus Listed (File No. E14840, Guide NKCR/NKCR7)
CE Marked
CCC Certified
Product Selection
| Build a Catalog Number |
4-Pole AC Coil Voltage (Ratings for 700-CF Only)
Ä AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220Ä becomes Cat. No. 700-CF220D for 120V, 60 Hz
| [V] | 12 | 24 | 32 | 36 | 42 | 48 | 100 | 100... 110 |
110 | 120 | 127 | 200 | 200... 220 |
208 | 208... 240 |
220... 230 |
230 | 230... 240 |
240 | 277 | 347 | 380 | 380... 400 |
400 | 400... 415 |
440 | 480 | 500 | 550 | 600 |
| 50 Hz | R | K | V | W | X | Y | KP | — | D | P | S | KG | L | — | — | F | — | VA | T | — | — | — | N | — | G | B | — | M | C | — |
| 60 Hz | Q | J | — | V | — | X | — | KP | — | D | — | — | KG | H | L | — | — | — | A | T | I | E | — | — | — | N | B | — | — | C |
| 50/60 Hz | — | KJ | — | — | — | KY | KP | — | KD | — | — | KG | KL | — | — | KL | KF | — | KA | — | — | — | — | KN | — | KB | — | — | — | — |
4-Pole DC Coil Voltage (Ratings for 700-CF Only)
⋆ Ratings for Bulletin 700-CFB and 700-CFM are on Specifications
Ä DC Coil Voltage Code♣
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220Ä becomes Cat. No. 700-CF220ZJ for 24V DC
| [V] | 9 | 12 | 24 | 36 | 48 | 48...72 | 60 | 64 | 72 | 80 | 110 | 110...125 | 115 | 125 | 220 | 220...250 | 230 | 250 |
| Standard | ZR | ZQ | ZJ | ZW | ZY | — | ZZ | ZB | ZG | ZE | ZD | — | ZP | ZS | ZA | — | ZF | ZT |
| Standard diode | — | — | DJ | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Electronic with diode | — | EQ | EJ | — | — | EY | — | — | — | — | — | ED | — | — | — | EA | — | — |
| ♣ When ordering DJ coil with built-in surge suppression, the DJ is not polarity sensitive. Drop out time: 14…20 ms. | ||||||||||||||||||
6- and 8-Pole Relays
|
|
Control Relays with Overlapping Side-Mounted Contacts
Control Relays with Standard Side-Mounted Contacts
Ä AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ0510Ä becomes Cat. No. 700-CFZ0510F.
| [V] | 12 | 24 | 32 | 36 | 42 | 48 | 100 | 100... 110 |
110 | 120 | 127 | 200 | 200... 220 |
208 | 208... 240 |
220... 230 |
230 | 230... 240 |
240 | 277 | 347 | 380 | 380... 400 |
400 | 400... 415 |
440 | 480 | 500 | 550 | 600 |
| 50 Hz | R | K | V | W | X | Y | KP | — | D | P | S | KG | L | — | — | F | — | VA | T | — | — | — | N | — | G | B | — | M | C | — |
| 60 Hz | Q | J | — | V | — | X | — | KP | — | D | — | — | KG | H | L | — | — | — | A | T | I | E | — | — | — | N | B | — | — | C |
| 50/60 Hz | — | KJ | — | — | — | KY | KP | — | KD | — | — | KG | KL | — | — | KL | KF | — | KA | — | — | — | — | KN | — | KB | — | — | — | — |
Assignment of Contacts
Device Combinations in Accordance with IEC 60947-1 / -4-1
Accessories
Auxiliary Contacts
| 700-CF (AC and DC electronic coils), vertical mounting, 60 °C♦ | |||||||
| Cat. No. 700… |
Max. N.O. Side Aux. |
Max. N.C. Side Aux. |
Max. N.O. Front Aux. |
Max. N.C. Front Aux. |
Max. N.O. Front + Side Aux. |
Max. N.C. Front + Side Aux. |
Max. N.O. + N.C. Front + Side Aux. |
| CF400 | 2 | 4 | 4 | 4 | 6 | 7 | 8 |
| CF310 | 2 | 4♣ | 4 | 4∆ | 6 | 5 | 8 |
| CF220 | 4 | 4♣ | 4 | 2 | 8 | 5 | 8 |
| CF040 | 2 | 2 | 4 | 0 | 6 | 2 | 6 |
| ♣ With no front auxiliary contacts installed. Otherwise 3 N.C. Maximum | |||||||
| ∆ With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum | |||||||
| ♦ For other operating conditions, please contact your local Rockwell Automation sales office or Allen‑Bradley distributor. | |||||||
| 700-CF (DC conventional coils), vertical mounting, 60 °C ♦ | |||||||
| Cat. No. 700… |
Max. N.O. Side Aux. |
Max. N.C. Side Aux. |
Max. N.O. Front Aux. |
Max. N.C. Front Aux. |
Max. N.O. Front + Side Aux. |
Max. N.C. Front + Side Aux. |
Max. N.O. + N.C. Front + Side Aux. |
| CF400 | 2 | 2 | 4 | 4∆ | 6 | 5 | 8 |
| CF310 | 2 | 2 | 4 | 4∆ | 6 | 5 | 8 |
| CF220 | 2 | 2 | 4 | 2 | 6 | 4 | 8 |
| ∆ With no side auxiliary contacts installed. Otherwise 3 N.C. Maximum | |||||||
| ♦ For other operating conditions, please contact your local Rockwell Automation sales office or Allen‑Bradley distributor. | |||||||
♦ Side or front mounted auxiliary contacts only, not both.
Control Modules
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 100-FL11Ä becomes Cat. No. 100-FL11J.§
| [V] | 24 | 48 | 100 | 110 | 120 | 230...240 | 240 | 277 | 380...400 | 400...415 | 440 | 480 |
| 50 Hz | K | Y | KP | D | — | VA | T | — | N | G | B | — |
| 60 Hz | J | — | — | — | D | — | A | T | — | — | N | B |
| § For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor. | ||||||||||||
| Cat. No. 100-JE | Cat. No. 100-JE12 | Cat. No. 100-JE48 | |||
| Electrical | |||||
| Input Voltage | 24V DC | 12V DC | 48V DC | ||
| Input Voltage Range | 18…30V DC | 6…12V DC | 35…48V DC | ||
| Output Voltage | 110…240V AC | 110…240V AC | 110…240V AC | ||
| Power Consumption | 0.1…0.4 W | 0.02…0.12 W | 0.2…0.5 W | ||
| Minimum Actuation | 5V DC, 2 mA DC | 5V DC, 2 mA DC | 5V DC, 2 mA DC | ||
| Mechanical | |||||
| Finger Protection | IP20 | IP20 | IP20 | ||
| Pickup Time | 0…10 ms + pickup time of the contactor |
0…10 ms + pickup time of the contactor |
0…10 ms + pickup time of the contactor |
||
| Dropout Time | 0…10 ms + dropout time of the contactor | 0…10 ms + dropout time of the contactor | 0…10 ms + dropout time of the contactor | ||
| Max. Cycles Per Second | 2⋆ | 2⋆ | 2⋆ | ||
| Isolation/Breakdown Voltage | In: 50V, Out: 250V | In: 50V, Out: 250V | In: 50V, Out: 250V | ||
| Rated Impulse Withstand Voltage | 4 kV | 4 kV | 4 kV | ||
| Environmental | |||||
| Ambient Temperature Range | -25…60 °C | -25…60 °C | -25…60 °C | ||
| Storage Temperature Range | -50…+80 °C | -50…80 °C | -50…80 °C | ||
| Operating Life | 100+ million ops | 100+ million ops | 100+ million ops | ||
| Construction | |||||
| Wire Size Range | Flexible wire | 1 Wire | 0.5…2.5 mm2 | 0.5…2.5 mm2 | 0.5…2.5 mm2 |
| 2 Wire | 0.75…2.5 mm2 | 0.75…2.5 mm2 | 0.75…2.5 mm2 | ||
| Solid wire | 1 Wire | 1.0…2.5 mm2 | 1.0…2.5 mm2 | 1.0…2.5 mm2 | |
| 2 Wire | 1.0…2.5 mm2 | 1.0…2.5 mm2 | 1.0…2.5 mm2 | ||
| Solid and Stranded | 18…14 AWG | 18…14 AWG | 18…14 AWG | ||
| Tightening Torque | 1…1.5 Nm/7…15 lbin | 1…1.5 Nm/7…15 lbin | 1…1.5 Nm/7…15 lbin | ||
| Type of Light | LED | LED | LED | ||
| ⋆ To consider the maximum operations/hour of the relays. | |||||
Assembly Components
Marking Systems
Uniform labelling materials for contactors, motor startup equipment, relays, and circuit breakers.
Coils
Specifications
General
| Main Relay Cat. Nos. 700-CF, 700S-CF |
Front Mounted Standard Auxiliary Contacts | Main Relay Cat. No. 700-CFB, 700S-CFB |
Master Relay Cat. No. 700-CFM |
Front Mounted Bifurcated Auxiliary Contacts | Side-mounted Auxiliary Contacts | |||
| Contact Ratings — NEMA | A600, P600 | A600, Q600 | A600, Q600 | 2 x A600, P600 | A600, Q600 | A600, Q600 | ||
| Min. Contact Rating | 17V, 10 mA | 17V, 5 mA | 8V, 5 mA | — | 5V, 3 mA | 17V, 10 mA | ||
| Contact Ratings — IEC AC-15 (solenoids, contactors) at rated voltage IEC 60947-5-1 |
24V | 10 A | 6 A | 3 A | 15 A | 3 A | 6 A | |
| 48V | 10 A | 6 A | 3 A | 15 A | 3 A | 6 A | ||
| 120V | 10 A | 6 A | 3 A | 15 A | 3 A | 6 A | ||
| 240V | 10 A | 5 A | 3 A | 15 A | 3 A | 5 A | ||
| 400V | 6 A | 3 A | 2 A | 7.5 A | 2 A | 3 A | ||
| 480V/500V | 2.5 A | 1.6 A | 1.2 A | 5 A | 1.2 A | 1.6 A | ||
| 600V | 1 A | 1 A | 0.7 A | 2 A | 0.7 A | 1 A | ||
| 690V | 1 A | 1 A | 0.7 A | 2 A | 0.7 A | 1 A | ||
| AC-12 (Control of resistive loads) IEC 60947-5-1 |
40 °C | Ith | 20 A | 10 A | 10 A | 20 A | 10 A | 10 A |
| 230V | 8 kW | |||||||
| 400V | 14 kW | |||||||
| 690V | 24 kW | |||||||
| 60 °C | Ith | 20 A | 6 A | 6 A | 20 A | 6 A | 6 A | |
| 230V | 8 kW | |||||||
| 400V | 14 kW | |||||||
| 690V | 24 kW | |||||||
| DC-12 Switching DC Loads L/R < 1ms, Resistive Loads IEC 60947-5-1 |
24V | 15 A | 10 A | 6 A | 20 A | 6 A | 6 A | |
| 48V | 10 A | 9 A | 3.2 A | 20 A | 3.2 A | 3.2 A | ||
| 110V | 6 A | 3.5 A | 1 A | 8 A | 1 A | 1 A | ||
| 220V | 1 A | 0.7 A | 0.5 A | 1.5 A | 0.5 A | 0.5 A | ||
| 440V | 0.4 A | 0.2 A | 0.2 A | 0.4 A | 0.2 A | 0.2 A | ||
| DC-13 IEC 60947-5-1, Solenoids and contactors | 24V | 5 A | 5 A | 2.5 A | 5 A | 2.5 A | 5 A | |
| 48V | 3 A | 3 A | 1.5 A | 3 A | 1.5 A | 2.5 A | ||
| 110V | 1.2 A | 1.2 A | 0.6 A | 1.2 A | 0.6 A | 0.68 A | ||
| 220V | 0.6 A | 0.6 A | 0.3 A | 0.6 A | 0.3 A | 0.32 A | ||
| 440V | 0.3 A | 0.15 A | 0.15 A | 0.3 A | 0.15 A | 0.15 A | ||
| DC Switching Ratings for 700-CF Main Poles in Series (Resistive Load at 60 °C) | |||
| 1 pole | 2 poles | 3 poles | |
| 24/48V | 25/20 A | 25 A | 25 A |
| 125V | 6 A | 25 A | 25 A |
| 220V | 1.5 A | 8 A | 25 A |
| 440V | 0.4 A | 1 A | 3 A |
Control Circuit
| Cat. No. 700-CF | |||
| Operating Voltage | |||
| AC 50/60 Hz | Pickup | [x Us] | 0.85…1.1 |
| Dropout | [x Us] | 0.3…0.6 | |
| DC⋆ | Pickup | [x Us] | 0.8…1.1 |
| Dropout | [x Us] | 0.1…0.6 | |
| Coil Consumption | |||
| AC 50/60 Hz | Inrush | [VA/W] | 70/50 |
| Seal | [VA/W] | 8/2.6 | |
| DC (conventional) | Inrush/Seal | [W] | 6.5 |
| DC (electronic) | Inrush (avg./ peak) | [W] | 10/17 |
| Seal | [W] | 1.7 | |
| Operating Times | |||
| AC 50/60 Hz | Pickup Time | [ms] | 15…30 |
| Dropout Time | [ms] | 10…60 | |
| DC (conventional) | Pickup Time | [ms] | 40…70 |
| Dropout Time | [ms] | 7…15 | |
| DC (electronic) | Pickup Time | [ms] | 25…50 |
| Dropout Time | [ms] | 25…50 | |
| Min OFF time | [ms] | 200 | |
| Max. ripple | ± 15% | ||
| Latch Attachment Release, 100-FL | |||
| Coil Consumption | AC | [VA/W] | 45/40 |
| DC | [W] | 25 | |
| Contact Signal Duration | [min./max] | 0.03…15 s | |
| Timing Attachment | |||
| Reset Time, 100-ETA, 100-ETB | at min. time setting | [ms] | 10 |
| at max. time setting | [ms] | 70 | |
| Repeat Accuracy | ± 10% | ||
| ⋆ For 9V DC, code ZR, use operating voltage 0.65…1.3 x Us. For 24V DC, code ZJ, DJ, or EJ use operating voltage 0.7…1.25 x Us. For 110V DC, code ED use operating voltage 0.7…1.25 x Us. |
|||
General
| Cat. No. 700-CF | |
| Rated Insulation Voltage Ui | |
| IEC | 690V |
| UL; CSA | 600V |
| Rated Impulse StrengthUimp | 6 kV |
| High Test Voltage 1 minute (per IEC 60947-4) |
2500V |
| Rated Voltage Ue | |
| AC | 115, 230, 400, 500, 690V |
| DC | 24, 48, 110, 220, 440V |
| Short-Circuit Protection gG Fuse 10 A | |
| Rated Frequency | 50/60 Hz, DC |
| Ambient Temperature | |
| Storage | 55…+80 °C (67…176 °F) |
| Operation at nominal current | 25…+60 °C (13…140 °F) |
| 15% current reduction for AC-12 at > 60 °C |
25…+70 °C (13…158 °F) |
| Corrosion Resistance | humid-alternating climate, cyclic, per IEC 60068-2-30 and DIN 50 016, 56 cycles |
| Altitude | 2000 m above mean sea level, per IEC60 947-4 |
| Type of Protection | |
| IP2X (IEC 60529 and DIN 40050) | in connected state |
| Shock Resistance | IEC 60068-2: Half sinusoidal shock 11 ms, 30 G (in 3 directions) |
| Vibration Resistance | IEC 60068-2: Static >2 G, in normal position no malfunction <5 G |
Utilization Category Table from EN 60947-5-1
| Verification of Making and Breaking Capacities of Switching Elements Under Normal Conditions Corresponding to the Utilization Categories |
|||||||||
| Utilization Category |
Normal Condition of Use | ||||||||
| Make§ | Break§ | Number and Rate of Making and Breaking operations | |||||||
| I/Ie | U/Ue | cos y | I/Ie | U/Ue | cos y | No. operating cycles♣ |
Operating cycles per minute |
ON time [s]♦ | |
| AC-12♠ | 1 | 1 | 0.9 | 1 | 1 | 0.9 | 6050 | 6 | 0.05 |
| AC-13♠ | 2 | 1 | 0.65 | 1 | 1 | 0.65 | 6050 | 6 | 0.05 |
| AC-14♠ | 6 | 1 | 0.3 | 1 | 1 | 0.3 | 6050 | 6 | 0.05 |
| AC-15♠ | 10 | 1 | 0.3 | 1 | 1 | 0.3 | 6050 | 6 | 0.05 |
| DC | — | — | T0.95 | — | — | T0.95 | — | — | — |
| DC-12 | 1 | 1 | 1 ms | 1 | 1 | 1 ms | 6050 | 6 | 0.05♦ |
| DC-13 | 1 | 1 | 6 x P∆ | 1 | 1 | 6 x P∆ | 6050 | 6 | 0.05♦ |
| DC-14♠ | 10 | 1 | 15 ms | 1 | 1 | 15 ms | 6050 | — | 0.05♦ |
| Ie Rated operational current, I Current to be made or broken | |||||||||
| Ue Rated operational voltage, U Voltage before make | |||||||||
| PUeIe Steady-state power consumption (W) | |||||||||
| T0.95 Time to reach 95% of the steady-state current (ms) | |||||||||
| See sub-clause 8.3.3.5.2. | |||||||||
| § For tolerances on test quantities, see sub-clause 8.3.2.2. | |||||||||
| ♣ The first 50 operating cycles shall be run at U/Ue=1.1 with the loads set at Ue. | |||||||||
| ∆ The value 6 x P results from an empirical relationship which is found to represent most DC magnetic loads to an upper limit of P = 50 W, e.g., 6 x P= 300 W. | |||||||||
| ♦ The ON time shall be at least equal to T0.95. | |||||||||
| ♠ Where the break current differs from the make current value, the ON time refers to the make current value after which the current is reduced to the break current value for a suitable period e.g., 0.05 s. | |||||||||
Contact Rating Table from EN 60947-5-1
| Examples of Contact Rating Designation Based on Utilization Categories | ||||||||||
| NEMA Designation ⋆ |
IEC Utilization Category |
Conventional Thermal Current Ithe (A) |
Rated Operational Current Ie (A) at Rated Operational Voltage Ue |
VA Rating | ||||||
| AC | 120V | 240V | 380V | 480V | 500V | 600V | Make | Break | ||
| A150 | AC-15 | 10 | 6 | — | — | — | — | — | 7200 | 720 |
| A300 | AC-15 | 10 | 6 | 3 | — | — | — | — | 7200 | 720 |
| A600 | AC-15 | 10 | 6 | 3 | 1.9 | 1.5 | 1.4 | 1.2 | 7200 | 720 |
| B150 | AC-15 | 5 | 3 | — | — | — | — | — | 3600 | 360 |
| B300 | AC-15 | 5 | 3 | 1.5 | — | — | — | — | 3600 | 360 |
| B600 | AC-15 | 5 | 3 | 1.5 | 0.95 | 0.75 | 0.72 | 0.6 | 3600 | 360 |
| C150 | AC-15 | 2.5 | 1.5 | — | — | — | — | — | 1800 | 180 |
| C300 | AC-15 | 2.5 | 1.5 | 0.75 | — | — | — | — | 1800 | 180 |
| C600 | AC-15 | 2.5 | 1.5 | 0.75 | 0.47 | 0.375 | 0.35 | 0.3 | 1800 | 180 |
| D150 | AC-14 | 1.0 | 0.6 | — | — | — | — | — | 432 | 72 |
| D300 | AC-14 | 1.0 | 0.6 | 0.3 | — | — | — | — | 432 | 72 |
| E150 | AC-14 | 0.5 | 0.3 | — | — | — | — | — | 216 | 36 |
| DC | 125V | 250V | 440V | 500V | 600V | — | — | — | ||
| N150 | DC-13 | 10 | 2.2 | — | — | — | — | — | 275 | 275 |
| N300 | DC-13 | 10 | 2.2 | 1.1 | — | — | — | — | 275 | 275 |
| N600 | DC-13 | 10 | 2.2 | 1.1 | 0.63 | 0.55 | 0.4 | — | 275 | 275 |
| P150 | DC-13 | 5 | 1.1 | — | — | — | — | — | 138 | 138 |
| P300 | DC-13 | 5 | 1.1 | 0.55 | — | — | — | — | 138 | 138 |
| P600 | DC-13 | 5 | 1.1 | 0.55 | 0.31 | 0.27 | 0.2 | — | 138 | 138 |
| Q150 | DC-13 | 2.5 | 0.55 | — | — | — | — | — | 69 | 69 |
| Q300 | DC-13 | 2.5 | 0.55 | 0.27 | — | — | — | — | 69 | 69 |
| Q600 | DC-13 | 2.5 | 0.55 | 0.27 | 0.15 | 0.13 | 0.1 | — | 69 | 69 |
| R150 | DC-13 | 1.0 | 0.22 | — | — | — | — | — | 28 | 28 |
| R300 | DC-13 | 1.0 | 0.22 | 0.1 | — | — | — | — | 28 | 28 |
| ⋆ This letter stands for the conventional thermal current and identifies AC or DC: e.g., B = 5 A AC. The number that follows is the rated insulation voltage. | ||||||||||
Approximate Dimensions
Approximate Dimensions are shown in millimeters (inches). Approximate Dimensions are not intended for manufacturing purposes.
Mounting Position
|
|
|
AC and DC Control Relays with 12V or 24V DC Electronic Coil
| Type | a | b | c | c1 | c2 | Æd | d1 | d2 |
| 700-CF, -CFB, -CFM |
45 (1-25/32) |
81 (3-3/16) |
80.5 (3-11/64) |
75.5 (3-3/32) |
6 (1/4) |
2 screws 4.5 (3/16) |
60 (2-23/64) |
35 (1-25/64) |
DC Control Relays with 110V or 220V DC Electronic Coil
| Type | a | b | c | c1 | c2 | Æd | d1 | d2 |
| 700-CF, -CFB, -CFM |
45 (1-25/32) |
105 (4-1/8) |
80.5 (3-11/64) |
75.5 (3-3/32) |
6 (1/4) |
2 screws 4.5 (3/16) |
60 (2-23/64) |
35 (1-25/64) |
DC Control Relays
| Type | a | b | c | c1 | c2 | Æd | d1 | d2 |
| 700-CF, -CFB, -CFM |
45 (1-25/32) |
81 (3-3/16) |
106.5 (4-3/16) |
101.5 (4) |
6 (1/4) |
2 screws 4.5 (3/16) |
60 (2-23/64) |
35 (1-25/64) |
Accessories
| Relay with | AC Control Relay | DC Control Relay | |||
| mm | (inches) | mm | (inches) | ||
| Auxiliary Contact for Front Mounting | 2- or 4-pole | c/c1 + 39 | (c/c1 + 1 37/64) | c/c1 + 39 | c/c1 + 1 37/64) |
| Auxiliary Contact for Side Mounting | 1- or 2-pole | a + 9 | (a + 23/64) | a + 9 | (a + 23/64) |
| Pneumatic Timing Module | — | c/c1 + 58 | (c/c1 + 2 23/64) | — | — |
| Solid-state Timing Module | on coil terminal side | b + 24 | (b + 15/16) | b + 24 | (b + 15/16) |
| Mechanical Latching | — | c/c1 + 61 | (c/c1 + 2 31/64) | — | — |
| DC Interface | on coil terminal side | b + 9 | (b + 23/64) | — | — |
| Surge Suppressor | on coil terminal side | b + 3 | (b + 1/8) | b + 3 | (b + 1/8) |
| Labelling with: | label sheet | +0 | (+0) | +0 | (+0) |
| — | marking tag with cover | +0 | (+0) | +0 | (+0) |
| — | marking tag carrier for System V4/V5 | +5.5 | (+7/32) | +5.5 | (+7/32) |
| — | marking tag carrier for System Bull. 1492W | +5.5 | (+7/32) | +5.5 | (+7/32) |