Catalogs > Industrial Controls Catalog > Relays, Timers, and Temperature Controllers > Industrial Relays and Timers > IEC Industrial Relays > Bulletin 700-CF Control Relay
Bulletin 700-CF Control Relay
| Introduction | Standards Compliance | Product Selection | Assignment of Contacts | Accessories | Specifications | Approximate Dimensions |
| Build a Catalog Number |
4-Pole AC Coil Voltage (Ratings for 700-CF Only)
Ä AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220Ä becomes Cat. No. 700-CF220D for 120V, 60 Hz
| [V] | 12 | 24 | 32 | 36 | 42 | 48 | 100 | 100... 110 |
110 | 120 | 127 | 200 | 200... 220 |
208 | 208... 240 |
220... 230 |
230 | 230... 240 |
240 | 277 | 347 | 380 | 380... 400 |
400 | 400... 415 |
440 | 480 | 500 | 550 | 600 |
| 50 Hz | R | K | V | W | X | Y | KP | — | D | P | S | KG | L | — | — | F | — | VA | T | — | — | — | N | — | G | B | — | M | C | — |
| 60 Hz | Q | J | — | V | — | X | — | KP | — | D | — | — | KG | H | L | — | — | — | A | T | I | E | — | — | — | N | B | — | — | C |
| 50/60 Hz | — | KJ | — | — | — | KY | KP | — | KD | — | — | KG | KL | — | — | KL | KF | — | KA | — | — | — | — | KN | — | KB | — | — | — | — |
4-Pole DC Coil Voltage (Ratings for 700-CF Only)
⋆ Ratings for Bulletin 700-CFB and 700-CFM are on Specifications
Ä DC Coil Voltage Code♣
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220Ä becomes Cat. No. 700-CF220ZJ for 24V DC
| [V] | 9 | 12 | 24 | 36 | 48 | 48...72 | 60 | 64 | 72 | 80 | 110 | 110...125 | 115 | 125 | 220 | 220...250 | 230 | 250 |
| Standard | ZR | ZQ | ZJ | ZW | ZY | — | ZZ | ZB | ZG | ZE | ZD | — | ZP | ZS | ZA | — | ZF | ZT |
| Standard diode | — | — | DJ | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Electronic with diode | — | EQ | EJ | — | — | EY | — | — | — | — | — | ED | — | — | — | EA | — | — |
| ♣ When ordering DJ coil with built-in surge suppression, the DJ is not polarity sensitive. Drop out time: 14…20 ms. | ||||||||||||||||||
6- and 8-Pole Relays
|
|
Control Relays with Overlapping Side-Mounted Contacts
Control Relays with Standard Side-Mounted Contacts
Ä AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CFZ0510Ä becomes Cat. No. 700-CFZ0510F.
| [V] | 12 | 24 | 32 | 36 | 42 | 48 | 100 | 100... 110 |
110 | 120 | 127 | 200 | 200... 220 |
208 | 208... 240 |
220... 230 |
230 | 230... 240 |
240 | 277 | 347 | 380 | 380... 400 |
400 | 400... 415 |
440 | 480 | 500 | 550 | 600 |
| 50 Hz | R | K | V | W | X | Y | KP | — | D | P | S | KG | L | — | — | F | — | VA | T | — | — | — | N | — | G | B | — | M | C | — |
| 60 Hz | Q | J | — | V | — | X | — | KP | — | D | — | — | KG | H | L | — | — | — | A | T | I | E | — | — | — | N | B | — | — | C |
| 50/60 Hz | — | KJ | — | — | — | KY | KP | — | KD | — | — | KG | KL | — | — | KL | KF | — | KA | — | — | — | — | KN | — | KB | — | — | — | — |