Bulletin 700S-CF Safety Control Relay

Introduction Standards Compliance Product Selection Assignment of Contacts Specifications Approximate Dimensions
Product Selection

Build a Catalog Number


Type CF and CFB Safety Control Relays — 8-Pole AC Coil Voltage (Ratings for 700S-CF Only)

AC-12 AC-15 Connection Diagrams Contacts Standard Contacts (Main)
Gold-Plated Bifuricated (Front)
Cat. No.
Gold-Plated Bifurcated, All Contacts
Cat. No.T 
Ie [A] Ie [A] Click to enlarge - 700CF-193-1
Main
Contacts
Auxiliary
Contacts
Click to enlarge - 700CF-186-2 Click to enlarge - 700SCF-197-6
  40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V N.O. N.C.
Main
Contacts
20 20 10 10 10 6 2.5 1 1 Click to enlarge - 700SCF-197-3 Click to enlarge - 700SCF-197-4 4 4 700S-CF440ÄBC 700S-CFB440ÄC
Click to enlarge - 700SCF-197-3 Click to enlarge - 700SCF-197-8 5 3 700S-CF530ÄBC 700S-CFB530ÄC
Adder
Deck
Contacts
10 6 6 6 5 3 1.6 1 1 Click to enlarge - 700SCF-197-3 Click to enlarge - 700SCF-197-10 6 2 700S-CF620ÄBC 700S-CFB620ÄC
  
T Ratings for Bulletin 700CFB and CFM are on Specifications

Ä AC Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700S-CF440ÄBC becomes Cat. No. 700S-CF440DBC for 120V, 60 Hz.

[V] 12 24 32 36 42 48 100 100-
110
110 120 127 200 200-
220
208 208-
240
220-
230
50 Hz R K V W X Y KP D P S KG L F
60 Hz Q J V X KP D KG H L
50/60 Hz KJ KY KP KD KG KL KL
  

[V] 230 230-
240
240 277 347 380 380-
400
400 400-
415
440 480 500 550 600
50 Hz VA T N G B M C
60 Hz A T I E N B C
50/60 Hz KF KA KN KB
  

Product Selection, Continued

Type CF and CFB Safety Control Relays — 8-Pole AC Coil Voltage (Ratings for 700S-CF Only)

AC-12 AC-15 Connection Diagrams Contacts Standard Contacts
Cat. No.¬ 
Gold Plated Bifurcated, All Contacts
Cat. No.¬ 
Ie [A] Ie [A] Click to enlarge - 700CF-193-1
Main
Contacts
Auxiliary
Contacts
Click to enlarge - 700CF-186-2 Click to enlarge - 700SCF-197-6
  40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V No. of N.O. Contacts No. of N.C. Contacts
Main Contacts 20 20 10 10 10 6 2.5 1 1 Click to enlarge - 700SCF-197-3 Click to enlarge - 700SCF-197-4 4 4 700S-CF440ÄC 700S-CFB440ÄC
Click to enlarge - 700SCF_197_7 Click to enlarge - 700SCF-197-8 5 3 700S-CF530ÄC 700S-CFB530ÄC
Adder Deck Contacts 10 6 6 6 5 3 1.6 1 1 Click to enlarge - 700SCF_197_9 Click to enlarge - 700SCF-197-10 6 2 700S-CF620ÄC 700S-CFB620ÄC
  
¬ Ratings for Bulletin 700-CFB and 700-CFM are on Specifications

Ä DC Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: 700S-CF440ÄC becomes Cat. No. 700S-CF440ZJC for 24V DC.

[V] 9 12 24 36 48 60 64 72 80 110 115 125 220 230 250
Standard ZR ZQ ZJ ZW ZY ZZ ZB ZG ZE ZD ZP ZS ZA ZF ZT
Standard with diode DJ
Electronic with diode EJ