Catalogs > Industrial Controls Catalog > Terminal Blocks and Wiring Systems > Wiring Systems
Wiring Systems
| Introduction | Standards Compliance and Certifications | Selecting a Wiring System | Catalog Number Explanation | 1746 Digital I/O Module Selection | 1746 Analog I/O Module Selection |
Bulletin 1746 SLC 500 AIFM and Cable — Selection Table
Analog I/O Modules ¬
| Description of AIFM | Cat. No. for Wiring System Module with Fixed Terminal Block | Cat. No. for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately) | I/O Module Cat. No. 1746-… | |||||||||||||||
| HSCE (IDiff.) | HSCE2 (Diff.) | FIO4I | FIO4V | NI4 | NI8 | NIO4I | NIO4V | NO4I | NO8I | NO4V | NO8V | NR4 | QS | NI16I | NI16V | |||
| Feed-through | ||||||||||||||||||
| 4-channel input, output or 2-in/2-out combination with 3 terminals/channel | 1492-AIFM4-3 | 1492-RAIFM4-3 | — | — | L | L | A | — | L | L | B | — | B | — | — | — | — | — |
| 6-channel isolated with 3…4 terminals/channel | 1492-AIFM6S-3 | 1492-RAIFM6S-3§ | — | — | — | — | — | — | — | — | — | — | — | — | D | — | — | — |
| 8-channel differential 16-channel single-ended with 3 terminals/channel | 1492-AIFM8-3 | 1492-RAIFM8-3§ | — | — | — | — | — | C | — | — | — | R | — | R | — | — | A46 | A46 |
| Thermocouple | ||||||||||||||||||
| 6-channel with 3 terminals/channelT | 1492-AIFM6TC-3 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| High-Speed Counter/Encoder | ||||||||||||||||||
| 2-channel counter input/4 outputs | 1492-AIFMCE4 | — | K | P | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Fused High-Speed Counter/Encoder | ||||||||||||||||||
| 2-channel fused counter input/4 fused outputs | 1492-AIFMCE4-F | — | K | P | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Fusible Analog | ||||||||||||||||||
| 2-channel output, 2-channel input with 24V blown fuse indicators, test points, 5 terminals/input, 3 terminals/output | 1492-AIFM4C-F-5 | — | — | — | L | L | — | — | L | L | — | — | — | — | — | — | — | — |
| 4-channel with 24V blown fuse indicators, test points, 5 terminals/input | 1492-AIFM4I-F-5 | — | — | — | — | — | A | — | — | — | — | — | — | — | — | — | — | — |
| 8-channel with 24V DC blown fuse indicators, 5 terminals/channel | 1492-AIFM8-F-5 | — | — | — | — | — | — | C | — | — | — | — | — | — | — | — | — | — |
| 16-channel input with 24V DC blown fuse indicators, 3 terminals/channel | 1492-AIFM16-F-3 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | A46 | A46 |
| 16-channel input with 24V DC blown fuse inidcators, 5 terminals/channel | 1492-AIFM16-F-5 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| 4-input/4-output channel with 8 fuses and 24V blown fuse indicators | 1492-AIFMQS | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Q | — | — |
| ¬ Pre-wired cables are available in standard length of 0.5, 1.0, 2.5, and 5.0 m. To order, insert the code for the desired cable length into the catalog number 005 = 0.5 m (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m), and insert the letter in the box. Example: Cat. No. 1402-ACABLE025A46 is for a 2.5 m cable, and the letter A. | ||||||||||||||||||
| T Cannot be used with SLC I/O. | ||||||||||||||||||
| Compatible RTB plug 1492-RTB8N (screw style terminal) or 1492-RTB8P. Order plugs separately. | ||||||||||||||||||
| § Compatible RTB plug 1492-RTB12N (screw style terminal) or 1492-RTB12P. Order plugs separately. | ||||||||||||||||||
| § Compatible RTB plug 1492-RTB16N (screw style terminal) or 1492-RTB16P. Order plugs separately. | ||||||||||||||||||
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1746 analog I/O module and a connector on the other end to plug into a 20- or 40-terminal IFM. To use this table, you must first select an IFM from the preceding table.
Pre-Wired Cables for Bulletin 1746 Analog I/O Modules
| Cable Cat. No. | Standard Cable Lengths (m) | Build-to-Order Available | AIFM Connector | Mating I/O Module Cat. No. |
| 1492-ACABLE¬ A | 0.5, 1.0, 2.5, 5.0 m | Yes | 15-pin D-shell | 1746-NI4 |
| 1492-ACABLE¬ B | 0.5, 1.0, 2.5, 5.0 m | Yes | 15-pin D-shell | 1746-NO4I, -NO4V |
| 1492-ACABLE¬ C | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-NI8 |
| 1492-ACABLE¬ D | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-NR4 |
| 1492-ACABLE¬ K | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-HSCE (Differential) |
| 1492-ACABLE¬ L | 0.5, 1.0, 2.5, 5.0 m | Yes | 15-pin D-shell | 1746-NIO4I, -NIO4V, -FIO4I, -FIO4V |
| 1492-ACABLE¬ P | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-HSCE2 (Differential) |
| 1492-ACABLE¬ Q | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-QS |
| 1492-ACABLE¬ R | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-NO8I, -NO8V |
| 1492-ACAB¬ A46 | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1746-NI16I, -NI16V |
| ¬ To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005A is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM4I-F-5 IFM to a Cat. No. 1746-NI4 I/O module. | ||||