Catalogs > Industrial Controls Catalog > Terminal Blocks and Wiring Systems > Wiring Systems
Wiring Systems
| Introduction | Standards Compliance and Certifications | Selecting a Wiring System | Catalog Number Explanation | 1746 Digital I/O Module Selection | 1746 Analog I/O Module Selection |
Bulletin 1756 ControlLogix AIFM and Cable Selection Table
Analog I/O Module¬ T
| Description of AIFM |
Cat. No. for Wiring System Module with Fixed Terminal Block | Cat. No. for Wiring Sytems Module with Removable Terminal Block Socket Assembly (order plugs separately) | I/O Module Cat. No. 1756-… | |||||||||||||||||||||||||||||
| HSC (24V Diff.) | HSC (5V Diff.) | IF4FXOF2F (Cur In & Out) | IF4FXOF2F (Volt In & Out) | IF4FXOF2F (Cur In & Volt Out) | IF6I (Current) | IF6I (Voltage) | IF6CIS (Current) | IF8 (Sgl-End Volt) | IF8 (Sgl-End Current) | IF8 (Diff Voltage) | IF8 (Diff Current) | IF8H (Voltage) | IF8H (Current/Hart) | IF16 (Sgl-End Volt) | IF16 (Sgl-End Current) | IF16 (Diff Voltage) | IF16 (Diff current) | IR6I | IT6I | IT6I2 | OF4 (Voltage) | OF4 (Current) | OF6CI | OF6VI | OF8 (Voltage) | OF8 (Current) | OF8H (Voltage) | OF8H (Current/Hart) | PIM | |||
| Feed-through | ||||||||||||||||||||||||||||||||
| 4-channel input, output or 2-in/2-out combination with 3 terminals/channel | 1492-AIFM4-3 | 1492-RAIFM4-3 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | VA | VB | — | — | — | — | — | — | — |
| 6-channel isolated with 3…4 terminals/channel | 1492-AIFM6S-3 | 1492-RAIFM6S-3§ | — | — | ZA | ZB | ZC | X | Y | Z | — | — | — | — | — | — | — | — | — | — | Z | — | — | — | — | Y | Y | — | — | — | — | — |
| 8-channel differential 16-channel single-ended with 3 terminals/channel | 1492-AIFM8-3 | 1492-RAIFM8-3§ | — | — | — | — | — | — | — | — | TA | TB | TC | TD | UC | UD | UA | UB | UC | UD | — | — | — | — | — | — | — | WA | WB | WA | WB | — |
| Thermocouple | ||||||||||||||||||||||||||||||||
| 6-channel with 3 terminals/channel | 1492-AIFM6TC-3 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | Y | YT | — | — | — | — | — | — | — | — | — |
| High-Speed Counter/Encoder | ||||||||||||||||||||||||||||||||
| 2-channel counter input/4 outputs | 1492-AIFMCE4 | — | XA | XB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Fusible High-Speed Counter/Encoder | ||||||||||||||||||||||||||||||||
| 2-channel fused counter input/4 fused outputs | 1492-AIFMCE4-F | — | XA | XB | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — |
| Fusible Analog | ||||||||||||||||||||||||||||||||
| 8-channel with 24V DC blown fuse indicators, 5 terminals/channel | 1492-AIFM8-F-5 | — | — | — | ZA | ZB | ZC | — | — | — | TA | TB | TC | TD | UC | UD | — | — | UC | UD | — | — | — | — | — | — | — | — | — | — | — | — |
| 16-channel input with 24V DC blown fuse indicators, 3 terminals/channel | 1492-AIFM16-F-3 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | UA | UB | UC | UD | — | — | — | — | — | — | — | — | — | — | — | — |
| 16-channel input with 24V DC blown fuse inidcators, 5 terminals/channel | 1492-AIFM16-F-5 | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | UA | UB | UC | UD | — | — | — | — | — | — | — | — | — | — | — | — |
| 8 input/2 output channels |
1492-AIFMPI | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | — | M |
| ¬ Some analog I/O modules can be operated in up to four modes (current/voltage, single-ended/differential) based on connections. In all cases, each channel is factory-configured for the same mode. However, you can field configure any channel for another mode. You may need to alter the terminal block wiring to match the application. Refer to the PLC I/O Module Installation Manual. | ||||||||||||||||||||||||||||||||
| T Cables are available in standard length of 0.5, 1.0, 2.5, and 5.0 m. To order, insert the code for the desired cable length into the catalog number 005 = 0.5 m (010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m), and insert the letter in the box. Example: Cat. No. 1402-ACABLE025TB is for a 2.5 m cable, and the letters TB. | ||||||||||||||||||||||||||||||||
| Compatible RTB plug 1492-RTB8N (screw style terminal) or 1492-RTB8P. Order plugs separately. 2 plugs per cat. no. | ||||||||||||||||||||||||||||||||
| § Compatible RTB plug 1492-RTB12N (screw style terminal) or 1492-RTB12P. Order plugs separately. 2 plugs per cat. no. | ||||||||||||||||||||||||||||||||
| § Compatible RTB plug 1492-RTB16N (screw style terminal) or 1492-RTB16P. Order plugs separately. 2 plugs per cat. no. | ||||||||||||||||||||||||||||||||
Bulletin 1756 ControlLogix AIFMs and Cables, Continued
These pre-wired cables have a pre-wired RTB on one end to connect to the front of a Bulletin 1756 analog I/O module and a D-shell connector on the other end to plug into a 20- or 40-terminal AIFM. You must first select the AIFM from the preceding selection table.
| Cat. No. | Standard Cable Lengths | Build-to-Order Available | AIFM Connector | Mating I/O Module Cat. No. |
| 1492-ACABLE¬ M | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1757-PIM |
| 1492-ACABLE¬ X | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF16 Current |
| 1492-ACABLE¬ Y | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF16 Voltage, -IT6I, -OF6CI, -OF6VI |
| 1492-ACABLE¬ YT | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IT6I2 |
| 1492-ACABLE¬ Z | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IR16, -IF6CIS |
| 1492-ACABLE¬ TA | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF8 Single-Ended Voltage |
| 1492-ACABLE¬ TB | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF8 Single-Ended Current |
| 1492-ACABLE¬ TC | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF8 Differential Voltage |
| 1492-ACABLE¬ TD | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF8 Differential Current |
| 1492-ACABLE¬ UA | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF16 Single-Ended Voltage |
| 1492-ACABLE¬ UB | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF16 Single-Ended Current |
| 1492-ACABLE¬ UC | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF16 Differential Voltage |
| 1492-ACABLE¬ UD | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF16 Differential Current |
| 1492-ACABLE¬ VA | 0.5, 1.0, 2.5, 5.0 m | Yes | 15-pin D-shell | 1756-OF4 Voltage |
| 1492-ACABLE¬ VB | 0.5, 1.0, 2.5, 5.0 m | Yes | 15-pin D-shell | 1756-OF4 Current |
| 1492-ACABLE¬ WA | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-OF8 Voltage |
| 1492-ACABLE¬ WB | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-OF8 Current |
| 1492-ACABLE¬ XA | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-HSC (24V DC Diff.) |
| 1492-ACABLE¬ XB | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-HSC (5V DC Diff.) |
| 1492-ACABLE¬ ZA | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF4FXOF2F (Cur In & Out) |
| 1492-ACABLE¬ ZB | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF4FXOF2F (Volt In & Out) |
| 1492-ACABLE¬ ZC | 0.5, 1.0, 2.5, 5.0 m | Yes | 25-pin D-shell | 1756-IF4FXOF2F (Cur In & Volt Out) |
| ¬ Cables are available in standard lengths of 0.5, 1.0, 2.5, and 5.0 m. To order, insert the code for the desired cable length into the cat. no. (005 = 0.5 m, 010 = 1.0 m, 025 = 2.5 m, and 050 = 5.0 m). Example: Cat. No. 1492-ACABLE005Y is for a 0.5 m cable that could be used to connect a Cat. No. 1492-AIFM6TC-3 analog IFM to a Cat. No. 1756-IT6I I/O module. | ||||