CENTERLINE Medium Voltage Motor Control Centers
Product Overview
|
Allen-Bradley medium voltage motor controllers are available in a wide range of control formats allowing the flexibility to select the best match for the application. Medium voltage full-voltage controllers, reduced-voltage controllers, solid-state reduced-voltage controllers, two-speed controllers, synchronous controllers, and load break switches provide integrated intelligence and the lowest-cost solution for starting motors. Visit medium voltage motor controllers on the Web at: http://www.ab.com/mvb/.
Allen-Bradley Medium Voltage MCC Competitive Advantage
ArcShield™ — Rockwell Automation has enhanced the safety of its world-recognized medium voltage control products to include an optional arc resistant class of medium voltage control equipment. ArcShield™ controllers provide the additional arc resistant safety features required by some industries. Most medium voltage control products can be provided with the ArcShield enclosure design which meets the arc resistant testing requirements of IEEE C37.20.7. ArcShield controllers use the same standard reliable internal components that continue to serve industries world wide.
SMC™ Flex — Solid-state reduced voltage controllers apply reduced voltage to a medium voltage AC motor to allow soft starting and stopping, limitation of the inrush current, and reduction of the effects of water hammer in pumping systems. Allen-Bradley medium voltage SMC Flex controllers include motor protection, communication and diagnostic capabilities, and high flexibility, making it ideal for virtually any application.
IntelliCENTER® — MCC users are provided with an integrated hardware, software, and communication solution. The IntelliCENTER features pre-configured software which shows real-time data, trending, component history, wiring diagrams, user manuals, and spare parts. The IntelliCENTER reduces installation time with its plug-and-play set-up and minimizes facility downtime by quickly providing intelligent diagnostic and predictive failure information.
For more information, see the following publications:
| Medium Voltage Controllers Selection Guide |
1500-SG001* |
| Medium Voltage Controllers Specification Guide |
1500-SR020* |
| OEM Products: Medium Voltage Controllers Application Guide |
1503-BR010* |
Description of Features
The Allen-Bradley medium voltage motor controller offers:
Three isolated compartments:
- Power bus
- Low voltage
- Power cell
Large swing-out low voltage panel painted white for high visibility
Test circuit and plug for remote control power supply
External operating handle to operate the isolation switch
Bolted power cell door(s)
CENTERLINE horizontal power bus with removable cover plates for accessibility
1/4 x 2 in. continuous copper ground bus
Line, load, and control wire conduit openings with removable cover
plates at the top or bottom of the structure
Base mounting sill channels with mounting holes and removable
lifting means
Hybrid epoxy powder paint finish
Controller Standard Features
NEMA Class E2 design
Removable lifting angles or brackets
Non-removable sill channels
Removable backplates
Top or bottom plates to accommodate cable entry/exit
Tin-plated copper horizontal power bus located in an isolated compartment
1/4 x 2 in. continuous bare copper ground bus
Main non-load break isolation switch with visible blades and shutter mechanism, and operating handle
Mechanical and electrical interlocks between isolation switch, vacuum contactor, and medium voltage door
Vacuum contactor(s)
Three current-limiting power fuses for NEMA Class E2 operation
Three current transformers
Control circuit transformer with primary and secondary fuses
Low voltage control panel
Space for necessary auxiliary control and metering devices
Polycarbonate viewing window in power cell door
IntelliVAC™ control module for each vacuum contactor, mounted in low voltage panel, with advanced features:
Universal input voltage (110…240V AC, 50/60 Hz or 100…250V DC)
Selectable vacuum contactor drop-out time and consistent pickup time
Altitude compensation
Power loss ride-through (TDUV) may require additional hardware (external capacitor)
Anti-kiss and anti-plugging protection
Delayed motor re-start and temporary motor jog function
One device is suitable for all contactors and control schemes
Input Voltage
2400V, 3300V, 4200V, 6600V or 6900V AC (+5/-10%)
3-phase 50/60 Hz (± 3%)
Ambient Temperature
0…40 °C (32…104 °F) with relative humidity of up to 95% (non-condensing)
Enclosure Types
NEMA Type 1 General purpose (IP10)
NEMA Type 1 w/g General purpose with gasket (IP21)
NEMA Type 12 Dust-tight and drip proof (IP52)
NEMA Type 3R Non walk-in weatherproof (IP34)
Arc Resistant (NEMA Type 12)
Accessibility Type 2
Tested per IEEE C37.20.7-2001
Standards
Canadian Standards Association (CSA), Industrial Control Equipment C22.2 No. 14 and TIL D-21
American Nation Standards Institute (ANSI), Instrument Transformers C57.13
Institute of Electrical & Electronic Engineers (IEEE)
National Electrical Code (NEC)
Occupational Safety & Health Act (OSHA)
Guide for Harmonic Control and Reactive Compensation of Static Power Converters (IEEE 519-1992)
National Electrical Manufacturers Association (NEMA), Medium Voltage Controllers Rated 1501…7200V AC ICS 3-2 (formerly ICS 2‑324)
Underwriters Laboratories, Inc. (UL), High Voltage Industrial Control Equipment 347
European Directives for EMC
Paint Finishes
Description Hybrid epoxy power paint
Color ANSI 49 medium light grey (standard)
ANSI 61 light grey (optional)
Procedure Continuous paint line. All parts are painted before assembly
Preparation Alkaline wash/rinse/iron phosphate
rinse/iron-chrome sealer
rinse/recirculated de-ionized water
rinse and virgin de-ionized water rinse
Painting Air-atomized electrostatic spray
Total paint thickness 0.002 in. (0.051 mm) minimum
Baking Natural gas oven at 179 °C (355 °F) minimum
Power Bus (Optional)
Located at the center rear of the structure
Mounted on the edge to a molded bus support insulator in a common vertical plane
CENTERLINE horizontal tin-plated copper bus
optional silver-plated or insulated
1200/2000/3000 A
Front/rear access
Ground Bus
Continuous bare copper ground bus 6 x 52 mm (1/4 x 2 in.) as standard
#8…#1/0 AWG or #6…250 MCM mechanical lug supplied at the incoming end of the lineup
Components
Advanced Digital Control of Vacuum Contactors
The Allen-Bradley Bulletin 1503VC IntelliVAC controller offers a superior and efficient means of controlling vacuum contactors. IntelliVAC controllers are a quantum leap beyond traditional electromechanical control circuits. Here are just a few of the beneficial characteristics:
The performance and flexibility of digital control, allowing the control of a wide array of contactor types (400 A, 800 A electrically held, and mechanical latch)
Enhanced reliability as a result of embedded self diagnostics and better coordination between unit power fuses and the vacuum contactor drop-out time
Increased productivity with features like power loss ride through (TDUV) and contactor anti-kiss, whichwere previously offered as optional features
Motor and process protection with delayed restart built in
Non-Load Break Isolation Switch
Electrical and mechanical interlocks prevent the switch from opening when the contactor is energized
Ensures normal operation only when the switch is fully closed
Allows for separate source testing when in the OFF position
Grounded in the OFF position
When in the open position, a visible barrier isolates the power cell from the power bus compartment
Status of the isolation switch can be viewed through a window in the power cell door
Handle and Interlock Mechanism
Simple direct drive mechanism improves reliability and ensures operator safety
Mechanical interlock mechanism remains part of the enclosure to eliminate setup adjustment
Power cell door is interlocked with the handle mechanism to prevent the door from being opened when the cell is energized
Low Voltage Compartment
Separate 120V source is required for Test position control power
Allows testing and troubleshooting of the power cell without exposing personnel to medium voltage
Prevents backfeeding medium voltage through the control transformer, in Test mode
All low voltage components are located in the low voltage panel
Low voltage panel interior painted white for better visibility
Power Cell Compartment
Power cell, low voltage panel, and bus compartment are isolated from each other for better fault containment
Swing out low voltage panel for easy access to install load cables
Isolated load cable compartments between top and bottom power cell
Easy access for cable installation and stress cones
Bar type current transformers are supplied as standard for overload protection and metering
Power Bus Compartment
CENTERLINE bus designed as an integral part of the structure
Dissipates heat more efficiently
Edge-to-edge configuration maximizes resistance to magnetic forces and minimizes moisture or dust collection
Molded bus brace reduces maintenance and provides better distribution of forces during a fault
Accessible without a ladder, for installation and maintenance
Allows for incoming line cables to enter through the top or bottom of the compartment
Rockwell Automation Medium Voltage MCC Competitive Advantage Details
ArcShield
|
|
The Allen-Bradley CENTERLINE ArcShield arc resistant controller provides rugged process control for applications requiring a higher level of personnel protection. ArcShield products are compliant to the IEEE C37.20.7 standard, and provide Type 2 protection. During an arc flash, the ArcShield controller safely redirects the arc flash energy out the top of the unit and away from personnel. This level of protection is also maintained when the low voltage door is open for maintenance purposes. Listed below are some product highlights.
Arc pressure relief vent
Safely vents arc gases and material away from personnel during an arc flash
Arc gases are vented out the top of the enclosure through the plenum exhaust structure
Heavy duty enclosure design
Reinforced side sheets, doors, roof, and back plates designed to contain arc flash energy while vents open
Added support plates secured with multiple bolts provide increased rigidity and security
Robust power cell door design
Multi-point latching mechanism, reinforced cross bracing and gasket sealing provide arc containment
A viewing window in the power cell door allows the operator to view the status of the isolation switch before opening the door
Once the latching mechanism is engaged, the power cell door is bolted shut for added protection
The ArcShield products are available in a number of different controller configurations.
These are just a few of the products available:
Bulletin 1591A Incoming units
Bulletin 1512A/AT One high controller
Bulletin 1512B/BT Two high controller
Bulletin 1562E MV SMC Flex controller
Bulletin 1506 Reversing Starter
SMC Flex
SMCs provide many features to benefit your system:
Minimize mechanical damage resulting from full voltage starting of AC induction motors, enabling longer system life
Limit line disturbances from inrush currents, resulting in reduced downtime
Multiple Start/Stop modes increase functionality
Diagnostic monitoring helps prevent problems before they occur
Satisfy electrical distribution restrictions by reducing inrush currents
SMCs are ideal for applications where:
Belts, gears, and chains can be damaged by across-the-line starting
Materials can be damaged by sudden starts and stops
A step change in torque can damage equipment
Power company line current restrictions are imposed
With SMC soft starters you benefit from:
Advanced diagnostics, increasing system performance
Greater product functionality for increased system flexibility
Decreased downtime due to advanced protection of motor winding, equipment, and materials
Medium Voltage SMC Flex Smart Motor Controller offers:
Standard control module
- Soft start - with selectable kickstart
- Soft stop
- Current limit start - with selectable kickstart
- Linear speed acceleration★ - with selectable kickstart
- Linear speed deceleration
- Full voltage
- Preset slow speed
Optional control module
- Pump control with separate start and stop profiles (eliminates water hammer)
Standard features of SMC Flex Controller
Electronic motor overload protection
Metering
Diagnostics
Built-in DPI communications (other communication options available)
Two-line, 16-character backlit LCD display keypad programming
Three programmable auxiliary contacts Medium Voltage SMC Flex Power Module
Current loop gate drive (patent pending)
Efficient heat sink profile
★ Requires motor tachometer.
IntelliCENTER
Spare parts lists specific to each unit
AutoCAD® elevation and on-line drawings
User manuals specific to each unit
Event logging, warnings, faults, parameter edits
Features pre-configured screens for each unit
Allows MCC monitoring from anywhere in the users facilities
Contains ActiveX controls to allow easy integration into RSView®