Connection Systems

Catalogs > Industrial Controls Catalog > Connection Systems > Panel Connection Systems

Panel Connection Systems

Description PanelConnect System View PanelConnect Input Features Product Selection — Input Modules PanelConnect™ Specifications Modules for 16-Point Inputs Pre-Wired Cables for Input PanelConnect
PanelConnect Output Features and Typical Configuration Product Selection — Output Modules Digital PanelConnect™ Output Specifications Digital PanelConnect™ Modules for Outputs Pre-Wired Cables for Output PanelConnect™ Combination PanelConnect Features Selecting Combination Products
Digital PanelConnect™ Combination Specifications Accessories Fuse Modules PanelConnect Digital, Option Module Cable Specifications 16-Point PanelConnect Input or Output Module Dimensions Pneumatic Valve Wiring Reference Guide
Selecting Combination Products

Follow these steps when starting selection from the I/O Module and PanelConnect:

1.  Determine the Input or Output voltage type. Use Table 1 for DC Outputs systems with Distribution Box connection.

2.  Determine the PLC I/O system that you are using, 1746, 1756, 1769, 1771, 1762, 1764, 1794

3.  The main connector for all combination modules is a Mini-Plus - 1 1/8 in. type.

4.  All available Distribution Box have LED indicators

5.  Select the appropriate PanelConnect module and a cable

6.  If Type 4X system is required, select from Table 2

Note:Appropriate Connection Systems suppliers are noted in Tables 1…3. Appropriate Pneumatic Valve suppliers are noted in Table 1.

Refer to Table 3 for each supplier for Distribution Box details.


Follow these steps when starting selection from Output Distribution Box and connect type:

Determine Output Distribution Box details, first

1.  Determine manufacturer of Distribution Box

2.  Determine voltage type DC, and nominal voltage

3.  Determine Distribution Box with LED

4.  Determine connection type

5.  Select PanelConnect Module and a cable

Refer to Table 1 to determine appropriate output system and PanelConnect Cable.


Follow these steps when starting selection from direct connect Pneumatic valves Manifold:

Determine Pneumatic Valve Manifold details, first

1.  Determine manufacturer of pneumatic valve

2.  Determine voltage type AC or DC

3.  Determine Pneumatic Valve series

4.  Select Valve Interface (Table 2 or 3)

5.  Select PanelConnect Module and a cable

Refer to Table 1 to determine appropriate output system and PanelConnect cable


Table 1. 32-Point Combination Modules

  DC Combination Input and Output  
  Distribution Box 5-pin DC micro, no LEDs, dual input/output per port 898D-54DT-N12 898D-54DT-N12
5-pin DC micro, no LEDs 898D-58PT-N12 898D-58PT-N12
5-pin DC micro, PNP LEDs 898D-P58PT-N12
5-pin DC micro, NPN LEDs 898D-N58PT-N12
Device Patchcords 889D-F4ACDM-§  889D-F4ACDM-§  889D-F4ACDM-§  889D-F4ACDM-§ 
Main Patchcord
Mini-plus ( 1-1/8 in.) 12-pin
889N-F12ACNU-§  889N-F12ACNU-§  889N-F12ACNU-§  889N-F12ACNU-§ 
PanelConnect 1667-32CD1201 1667-32CD1202 1667-32CD1203 1667-32CD1204
Allen-Bradley Input Systems     Allen-Bradley Output Systems
I/O System Nominal Input Range Type Module Input Module Input CableT  Output Cable‡  Input CableT  Output Cable‡  Input CableT  Output Cable‡  Input CableT  Output Cable‡  Nominal Input Range Type Module Output Module
1746 24V DC 10…30V Sink 1746-IB16 1492-CABLE¬ B 1492-CABLE¬ E 24V DC 10…30V Source 1746-OB16E
24V DC 10…30V AC/DC Sink 1746-IN16 1492-CABLE¬ B 1492-CABLE¬ E 24V DC 10…30V Source 1746-OB16E
24V DC 10…30V DC Sink 1746-ITB16 1492-CABLE¬ B 1492-CABLE¬ E 24V DC 10…30V Source 1746-OB16E
24V DC 10…30V DC Source 1746-ITV16 1492-CABLE¬ E 1492-CABLE¬ E 24V DC 10…50V DC Sink 1746-OV16
24V DC 10…30V DC Source 1746-IV16 1492-CABLE¬ B 1492-CABLE¬ E 24V DC 20…26V DC Sink 1746-OVP16
1756 24V DC 10…30V DC Sink 1756-IB16 1492-CABLE¬ X 1492-CABLE¬ X 24V DC 10…30V DC Source 1756-OB16E
1769 24V DC 10…30V DC Sink Only 1769-IQ16 (Sink Mode) 1492-CAB¬ B69 1492-CAB¬ E69 24V DC 20…26V DC Source 1769-OB16
24V DC 10…30V DC Source 1769-IQ16 (Source Mode) 1492-CAB¬ B69 1492-CAB¬ E69 24V DC 20…26V DC Sink 1769-OV16
1771 24V DC 10…30V DC Sink
Only
1771-IBD 1492-CABLE¬ F 1492-CABLE¬ F 24V DC 10…50V DC Source 1771-OBD
24V DC 20…60V DC Sink 1771-ICD 1492-CABLE¬ F 1492-CABLE¬ F 24V DC 10…50V DC Source 1771-OBD
24V DC 9…30V DC Sink 1771-IND 1492-CABLE¬ F 1492-CABLE¬ F 24V DC 10…50V DC Source 1771-OBD
1794 24V DC 10…30V DC Sink 1794-IB16 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P 24V DC 10…30V DC Source 1794-OB16
  
¬ Cables are available in standard lengths of 0.5 m, 1.0 m, and 5.0 m. To order, insert the desired length code in the catalog number (“005” = 0.5 m, “010” = 1.0 m, “0.25” = 2.5 m, and “050” = 5 m). Example:
1492-CABLE005B is for a 0.5 m cable for the 1746-IB16 I/O module. 1492-CABLE¬ P has minimum length of 1.0 m.
T The input cable mates to the Allen-Bradley input system input module.
‡ The output cable mates to the Allen-Bradley input system output module.
§ Mini patchcords are available in standard lengths of 0.9 m, 1.8 m, 3.6 m, and 6 m (3 ft., 6 ft., 12 ft., and 20 ft.). To order, insert the desired length in the catalog number. Example: 889N-F12ACNU-2 represents a 2 m (6.5 ft.) patchcord. Note catalog number reflects straigh male to straight female version with 18/22 AWG conductors, additional models are also available.
§ DC micro patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889D-F4ACDM-2 represents a 2 m (6.5 ft.) patchcord. Note catalog number reflects straight male to straight female version with 18/22 AWG conductors, additional models are also available.

Note:PNP type disitrubtion boxes require sink type PLC inputs and source type PLC outputs. NPN type distribution boxes require source type PLC inputs and sink type PLC outputs.