Catalogs > Industrial Controls Catalog > Connection Systems > Panel Connection Systems
Panel Connection Systems
| Description | PanelConnect System View | PanelConnect Input Features | Product Selection — Input Modules | PanelConnect™ Specifications | Modules for 16-Point Inputs | Pre-Wired Cables for Input PanelConnect |
Follow these steps when starting selection from the I/O Module and PanelConnect:
1. Determine the Input or Output voltage type. Use Table 1 for DC Outputs systems with Distribution Box connection.
2. Determine the PLC I/O system that you are using, 1746, 1756, 1769, 1771, 1762, 1764, 1794
3. The main connector for all combination modules is a Mini-Plus - 1 1/8 in. type.
4. All available Distribution Box have LED indicators
5. Select the appropriate PanelConnect module and a cable
6. If Type 4X system is required, select from Table 2
Note:Appropriate Connection Systems suppliers are noted in Tables 1…3. Appropriate Pneumatic Valve suppliers are noted in Table 1.
Refer to Table 3 for each supplier for Distribution Box details.
Follow these steps when starting selection from Output Distribution Box and connect type:
Determine Output Distribution Box details, first
1. Determine manufacturer of Distribution Box
2. Determine voltage type DC, and nominal voltage
3. Determine Distribution Box with LED
4. Determine connection type
5. Select PanelConnect Module and a cable
Refer to Table 1 to determine appropriate output system and PanelConnect Cable.
Follow these steps when starting selection from direct connect Pneumatic valves Manifold:
Determine Pneumatic Valve Manifold details, first
1. Determine manufacturer of pneumatic valve
2. Determine voltage type AC or DC
3. Determine Pneumatic Valve series
4. Select Valve Interface (Table 2 or 3)
5. Select PanelConnect Module and a cable
Refer to Table 1 to determine appropriate output system and PanelConnect cable
Table 1. 32-Point Combination Modules
| DC Combination Input and Output | ||||||||||||||||
| Distribution Box | 5-pin DC micro, no LEDs, dual input/output per port | 898D-54DT-N12 | — | — | 898D-54DT-N12 | |||||||||||
| 5-pin DC micro, no LEDs | 898D-58PT-N12 | — | — | 898D-58PT-N12 | ||||||||||||
| 5-pin DC micro, PNP LEDs | 898D-P58PT-N12 | — | ||||||||||||||
| 5-pin DC micro, NPN LEDs | — | — | — | 898D-N58PT-N12 | ||||||||||||
| Device Patchcords | 889D-F4ACDM-§ | 889D-F4ACDM-§ | 889D-F4ACDM-§ | 889D-F4ACDM-§ | ||||||||||||
| Main Patchcord Mini-plus ( 1-1/8 in.) 12-pin |
889N-F12ACNU-§ | 889N-F12ACNU-§ | 889N-F12ACNU-§ | 889N-F12ACNU-§ | ||||||||||||
| PanelConnect | 1667-32CD1201 | 1667-32CD1202 | 1667-32CD1203 | 1667-32CD1204 | ||||||||||||
| Allen-Bradley Input Systems | Allen-Bradley Output Systems | |||||||||||||||
| I/O System | Nominal | Input Range | Type Module | Input Module | Input CableT | Output Cable | Input CableT | Output Cable | Input CableT | Output Cable | Input CableT | Output Cable | Nominal | Input Range | Type Module | Output Module |
| 1746 | 24V DC | 10…30V | Sink | 1746-IB16 | 1492-CABLE¬ B | 1492-CABLE¬ E | — | — | — | — | — | — | 24V DC | 10…30V | Source | 1746-OB16E |
| 24V DC | 10…30V AC/DC | Sink | 1746-IN16 | 1492-CABLE¬ B | 1492-CABLE¬ E | — | — | — | — | — | — | 24V DC | 10…30V | Source | 1746-OB16E | |
| 24V DC | 10…30V DC | Sink | 1746-ITB16 | 1492-CABLE¬ B | 1492-CABLE¬ E | — | — | — | — | — | — | 24V DC | 10…30V | Source | 1746-OB16E | |
| 24V DC | 10…30V DC | Source | 1746-ITV16 | — | — | — | — | — | — | 1492-CABLE¬ E | 1492-CABLE¬ E | 24V DC | 10…50V DC | Sink | 1746-OV16 | |
| 24V DC | 10…30V DC | Source | 1746-IV16 | — | — | — | — | — | — | 1492-CABLE¬ B | 1492-CABLE¬ E | 24V DC | 20…26V DC | Sink | 1746-OVP16 | |
| 1756 | 24V DC | 10…30V DC | Sink | 1756-IB16 | — | — | 1492-CABLE¬ X | 1492-CABLE¬ X | — | — | — | — | 24V DC | 10…30V DC | Source | 1756-OB16E |
| 1769 | 24V DC | 10…30V DC | Sink Only | 1769-IQ16 (Sink Mode) | 1492-CAB¬ B69 | 1492-CAB¬ E69 | — | — | — | — | — | — | 24V DC | 20…26V DC | Source | 1769-OB16 |
| 24V DC | 10…30V DC | Source | 1769-IQ16 (Source Mode) | — | — | — | — | — | — | 1492-CAB¬ B69 | 1492-CAB¬ E69 | 24V DC | 20…26V DC | Sink | 1769-OV16 | |
| 1771 | 24V DC | 10…30V DC | Sink Only |
1771-IBD | — | — | — | — | 1492-CABLE¬ F | 1492-CABLE¬ F | — | — | 24V DC | 10…50V DC | Source | 1771-OBD |
| 24V DC | 20…60V DC | Sink | 1771-ICD | — | — | — | — | 1492-CABLE¬ F | 1492-CABLE¬ F | — | — | 24V DC | 10…50V DC | Source | 1771-OBD | |
| 24V DC | 9…30V DC | Sink | 1771-IND | — | — | — | — | 1492-CABLE¬ F | 1492-CABLE¬ F | — | — | 24V DC | 10…50V DC | Source | 1771-OBD | |
| 1794 | 24V DC | 10…30V DC | Sink | 1794-IB16 | 1492-CABLE¬ P | 1492-CABLE¬ P | — | — | — | — | 1492-CABLE¬ P | 1492-CABLE¬ P | 24V DC | 10…30V DC | Source | 1794-OB16 |
| ¬ Cables are available in standard lengths of 0.5 m, 1.0 m, and 5.0 m. To order, insert the desired length code in the catalog number (005 = 0.5 m, 010 = 1.0 m, 0.25 = 2.5 m, and 050 = 5 m). Example: 1492-CABLE005B is for a 0.5 m cable for the 1746-IB16 I/O module. 1492-CABLE¬ P has minimum length of 1.0 m. |
||||||||||||||||
| T The input cable mates to the Allen-Bradley input system input module. | ||||||||||||||||
| The output cable mates to the Allen-Bradley input system output module. | ||||||||||||||||
| § Mini patchcords are available in standard lengths of 0.9 m, 1.8 m, 3.6 m, and 6 m (3 ft., 6 ft., 12 ft., and 20 ft.). To order, insert the desired length in the catalog number. Example: 889N-F12ACNU-2 represents a 2 m (6.5 ft.) patchcord. Note catalog number reflects straigh male to straight female version with 18/22 AWG conductors, additional models are also available. | ||||||||||||||||
| § DC micro patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889D-F4ACDM-2 represents a 2 m (6.5 ft.) patchcord. Note catalog number reflects straight male to straight female version with 18/22 AWG conductors, additional models are also available. | ||||||||||||||||
Note:PNP type disitrubtion boxes require sink type PLC inputs and source type PLC outputs. NPN type distribution boxes require source type PLC inputs and sink type PLC outputs.