Catalogs > Industrial Controls Catalog > Connection Systems > Panel Connection Systems
Panel Connection Systems
| Description | PanelConnect System View | PanelConnect Input Features | Product Selection — Input Modules | PanelConnect™ Specifications | Modules for 16-Point Inputs | Pre-Wired Cables for Input PanelConnect |
|
PanelConnect Fuse Module
The PanelConnect fuse module provides a convenient method of adding overcurrent protection to your PanelConnect inputs and outputs. This module has sixteen or thirty-two (16 or 32) 5x20 fuse holders to protect each individual input or output. The module has two 20-pin or 40-pin connectors with locking tabs. The right connector is used to connect to the back of the PanelConnect (in-panel connector). The left connector is used to connect to the Input or Output PLC module. The connection between the PanelConnect Module and the Fuse Module is done via the PanelConnect Option Module cable while connection to the PLC is done via PanelConnect pre-wired cables. This module is optional so OEMs can add fusing based on the needs of their customers.
|
Digital Option Module Cables
PanelConnect Option Module cable has two over molded cable connectors. The cables use #22 AWG wire and are 100% tested for continuity to make a perfect connection between the fuse module and PanelConnect Module every time. These cables are offered in five standard lengths of 0.5, 1.0, 1.5, 2.5, and 5.5 meters to fit a variety of applications.
|
Sealing Caps
To maintain the Type 4, 4X, and 12 enclosure rating, these accessory caps must be used if both field side connectors are not permanently terminated. Hand tighten plus one quarter turn.
|
| PanelConnect Catalog Number |
1667-ZC1¬ Mini-Plus 1-1/8 in. |
1667-ZC2¬ M23 |
PanelConnect Catalog Number |
1667-ZC1¬ Mini-Plus 1-1/8 in. |
1667-ZC2¬ M23 |
| 1667-16IA1008 | X | 1667-16OD1202 | X | ||
| 1667-16IA1207 | X | 1667-16OD1203 | X | ||
| 1667-16IA2209 | X | 1667-16OD1204 | X | ||
| 1667-16ID1001 | X | 1667-16OD1205 | X | ||
| 1667-16ID1004 | X | 1667-16OD1206 | X | ||
| 1667-16ID1201 | X | 1667-16OD1207 | X | ||
| 1667-16ID1202 | X | 1667-16OD2201 | X | ||
| 1667-16ID1203 | X | 1667-16OD2202 | X | ||
| 1667-16ID1210 | X | 1667-16OD2203 | X | ||
| 1667-16ID1212 | X | 1667-16OD2204 | X | ||
| 1667-16ID2205 | X | 1667-16OD2205 | X | ||
| 1667-16ID2206 | X | 1667-32CO1201 | X | ||
| 1667-16ID2211 | X | 1667-32CO1202 | X | ||
| 1667-16ID2213 | X | 1667-32CO1203 | X | ||
| 1667-16OA1201 | X | 1667-32CO1204 | X | ||
| 1667-16OA1202 | X | 1667-32ID1201 | X | ||
| 1667-16OA1203 | X | 1667-32ID1202 | X | ||
| 1667-16OD1201 | X | 1667-32OA1201 | X | ||
| ¬ Add X to Cat. No. for NEMA 4X sealing cap | |||||
Mounting Bracket
|
Use the above bracket (1667-ZB) when mounting the PanelConnect module within an enclosure.
Marker Cards
Each PanelConnect is provided with markers ¬ , T installed in the front of the module. The center marker T indicates whether the module is an input or output combined device. The blank markers ¬ are for customer use to mark I/O address or cable reference. In addition, each PanelConnect is provided with a tree of five markers for machine marking. Replacement and spare markers are available as accessories, 1492-M9X20.
Voltage Marking Ring
Each PanelConnect™ module is provided with two voltage marking rings( ). AC modules use the red rings provided and DC modules use the blue rings.
|
|
The same information for Type 4 applies to Type 4X products as shown in Tables 1 and 2 for Cables and Distribution Boxes.
Table 2. Type 4X Input Systems
| Type 4X Module | Type 4 Module |
| ¬ | 1667-32CD1201 |
| ¬ | 1667-32CD1202 |
| ¬ | 1667-32CD1203 |
| ¬ | 1667-32CD1204 |
| ¬ Contact factory for availability | |
Adhesive Label Cards for 16-Point Input PanelConnect Modules
Each PanelConnect™ module is provided with an adhesive label card. The label card is made available for the back of the PanelConnect Module and provides the power supply connector descriptions. The label strips provides the wiring description from the input module power connections.
The label lists ( ) all of the compatible input modules and their respective power wiring descriptions. Depending on the input module that is used, the label strip is simply peeled from the label card and applied to the back side power supply connector ( ).
In addition, blank labels are provided for:
| 1667-16IA1008 | 1667-16ID1001 | 1667-16ID2205 |
| 1667-16IA1207 | 1667-16ID1004 | 1667-16ID2206 |
| 1667-16IA2209 | 1667-16ID1201 | 1667-16ID2211 |
| 1667-16ID1202 | 1667-16ID2213 | |
| 1667-16ID1203 | ||
| 1667-16ID1212 |
|
16-Point Input Label Card with Labels
|
Adhesive Label Cards for 16-Point Output PanelConnect Modules
Each PanelConnect™ module is provided with an adhesive label card. The label card is made available for the back of the PanelConnect Module and provides the power supply connector descriptions. The label strips provides the wiring description from the input module power connections.
The label lists ( )all of the compatible input modules and their respective power wiring descriptions. Depending on the input module that is used, the label strip is simply peeled from the label card and applied to the back side power supply connector ( ).
In addition, blank labels are provided for:
| 1667-16OA1201 | 1667-16OD1201 | 1667-16OD2201 | 1667-16OD2204 |
| 1667-16OA1202 | 1667-16OD1202 | 1667-16OD2202 | 1667-16OD2205 |
| 1667-16OA1203 | 1667-16OD1203 | 1667-16OD2203 | |
| 1667-16OD1204 | |||
| 1667-16OD1205 | |||
| 1667-16OD1206 | |||
| 1667-16OD1207 |
|
16-Point Output Label Card with Labels
|
Adhesive Label Cards for 32-Point Input, Output and Combination Input/Output PanelConnect Modules
Each PanelConnect™ module is provided with an adhesive label card. The label card is made available for the back of the PanelConnect Module and provides the power supply connector descriptions. The label strips provides the wiring description from the input module power connections.
The label lists ( ) all of the compatible input modules and their respective power wiring descriptions. Depending on the input module that is used, the label strip is simply peeled from the label card and applied to the back side power supply connector ( ).
In addition, blank labels are provided for:
| Combination | Input | Output |
| 1667-32CD1201 | 1667-32ID1001 1667-32ID12001 |
1667-32OD1201 |
| 1667-32CD1202 | ||
| 1667-32CD1203 | ||
| 1667-32CD1204 | ||
|
|