Connection Systems

Catalogs > Industrial Controls Catalog > Connection Systems > Panel Connection Systems

Panel Connection Systems

Description PanelConnect System View PanelConnect Input Features Product Selection — Input Modules PanelConnect™ Specifications Modules for 16-Point Inputs Pre-Wired Cables for Input PanelConnect
PanelConnect Output Features and Typical Configuration Product Selection — Output Modules Digital PanelConnect™ Output Specifications Digital PanelConnect™ Modules for Outputs Pre-Wired Cables for Output PanelConnect™ Combination PanelConnect Features Selecting Combination Products
Digital PanelConnect™ Combination Specifications Accessories Fuse Modules PanelConnect Digital, Option Module Cable Specifications 16-Point PanelConnect Input or Output Module Dimensions Pneumatic Valve Wiring Reference Guide
Click to enlarge - Input_Output_Sys


¬ PanelConnect 16- and 32-point Input...Digital Pre-Wired Cables

T PanelConnect 16- and 32-point Output…Table 1. AC Output Systems NEMA Type 4

‡ Wiring Systems Cable

§ Main Patchcord (Mini-Plus)


§ Distribution Box

Ø Device Patchcords

z Sealing Caps


ª Inductive Proximity...See the Sensors Catalog

v Photoelectric Sensor…See the Sensors Catalog

ª Limit Switch…See the Sensors Catalog


Click to enlarge - UsingSelecTable [Converted]


Product Selection — Input Modules

Using Selection Tables to Make Valid Catalog Numbers

Configure the cable catalog number using 1492-CABLE¬  (for digital cables). See footnote ¬  on pages Table 1. AC Input Systems NEMA Type 4 and .

Table 1. AC Input Systems NEMA Type 4

  Catalog Number
  Allen-Bradley Distribution Box 3-pin mini, no LED 898N-38PS-N10
3-pin mini, LEDs 898N-L38PS-N12
3-pin AC micro, no LED 898R-38PS-N10
3-pin AC micro, LED 898R-L38PS-N12
Allen-Bradley Device Patchcords 889N-F3AFNU-‡ F 889R-F3AERM-§ 
Allen-Bradley Main Patchcords 10-pin Mini Plus 12-pin Mini Plus 10-pin Mini Plus 12-pin Mini Plus
889N-F10ACNU-§  889N-F12ACNU-§  889N-F10ACNU-§  889N-F12ACNU-§ 
Allen-Bradley PanelConnect (16-input) 1667-16IA1008 1667-16IA1207 1667-16IA1008 1667-16IA1207
System  
I/O System Nominal
System
I/O Range Frequency
Module
I/O Module Cat. No. Cat. No. Cat. No. Cat. No.
1746 100/120V AC 85…132V AC 47…63 Hz 1746-IA16 1492-CABLE¬ A 1492-CABLE¬ A 1492-CABLE¬ A 1492-CABLE¬ A
24V AC 10…30V AC 47…63 Hz 1746-IN16 1492-CABLE¬ B 1492-CABLE¬ B 1492-CABLE¬ B 1492-CABLE¬ B
1756 120V AC 74…132V AC 47…63 Hz 1756-IA16 1492-CABLE¬ X 1492-CABLE¬ X 1492-CABLE¬ X 1492-CABLE¬ X
24V AC 10…30V AC 47…63 Hz 1756-IN16 1492-CABLE¬ X 1492-CABLE¬ X
1769 100/120V AC 79…132V AC 47…63 Hz 1769-IA16 1492-CAB¬ A69 1492-CAB¬ A69 1492-CAB¬ A69 1492-CAB¬ A69
1771 120V AC 70…138V AC 50/60 Hz 1771-IAD 1492-CABLE¬ F 1492-CABLE¬ F 1492-CABLE¬ F 1492-CABLE¬ F
24V AC 16…30V AC 50/60 Hz 1771-IND 1492-CABLE¬ F 1492-CABLE¬ F 1492-CABLE¬ F 1492-CABLE¬ F
1764 100/120V AC 79…132V AC 47…63 Hz 1764-24AWA 1492-CAB¬ A64 1492-CAB¬ A64 1492-CAB¬ A64 1492-CAB¬ A64
1794 100/120V AC 85…132V AC 47…63 Hz 1794-IA16 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P
Other AC PLC Input Modules 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P
  
¬ PanelConnect to PLC I/O module cables are available in standard lengths of 0.5 m, 1.0 m, and 5.0 m. To order, insert the desired length code in the catalog number (“005” = 0.5 m, “010” = 1.0 m, “0.25” = 2.5 m, and “050” = 5 m). Example: 1492-CABLE005B is for a 0.5 m cable for the 1746-IB16 I/O module. 1492-CABLE¬ P has minimum length of 1.0 m.
‡ Mini patchcords are available in standard lengths of 0.9 m, 1.8 m, 3.6 m, and 6 m (3 ft, 6 ft, 12 ft, and 20 ft). To order, insert the desired length in
the catalog number. Example: 889N–F3AFNU–3F represents a mini 0.9 m (3 ft) patchcord. Note catalog number reflects straight male to
straight female version with 16 AWG conductors, additional models are also available.
§ AC micro patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889R–F3AERM–3 represents an AC micro 3 m (9.8 ft) patchcord. Note catalog number reflects straight male to straight female version with 18 AWG conductors, additional models are also available.
§ Mini-Plus patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889N–F12ACNU–2 represents a 2 m (6.5 ft) patchcord. Note catalog number reflects straight male to straight female version with 18/22 AWG conductors, additional models are also available.

Table 2. DC Input Systems NEMA Type 4

  Catalog Number
  Allen-Bradley Distribution Box 5-pin DC micro, no LED 898D-58PT-N12
5-pin DC micro, PNP LED 898D-P58PT-N12 898D-P58PT-N12
5-pin DC micro, NPN LED 898D-N58PT-N12
4-pin mini, no LED 898N-48PS-N10 898N-48PS-N10
Allen-Bradley Device Patchcords 889B-F4AFNU-‡ F 889D-F4ACDM-§  889D-F4AFNU-‡ F
Allen-Bradley Main Patchcords 10-pin Mini Plus 12-pin Mini Plus 10-pin Mini Plus
889N-F10ACNU-§  889N-F12ACNU-§  889N-F10ACNU-§ 
PanelConnect (16-input) 1667-16ID1004 1667-16ID1001 1667-16ID1201 1667-16ID1212
PanelConnect (32-input) 1667-32ID1201 1667-32ID1001
System  
I/O System Nominal System (DC) I/O Range (DC)‡  Type Module I/O Module  
1746 24V DC 10…30V DC Sink 1746-IB16 1492-CABLE¬ B 1492-CABLE¬ B
48V DC 30…60V DC Sink 1746-IC16 1492-CABLE¬ B
120V DC 90…146V DC Sink 1746-IH16 1492-CABLE¬ B
24V DC 10…30V DC Sink 1746-IN16 1492-CABLE¬ B 1492-CABLE¬ B
24V DC 10…30V DC Sink 1746-ITB16 1492-CABLE¬ B 1492-CABLE¬ B
24V DC 10…30V DC Source 1746-ITV16 1492-CABLE¬ B 1492-CABLE¬ BT 
24V DC 10…30V DC Source 1746-IV16 1492-CABLE¬ B 1492-CABLE¬ BT 
24V DC 30…60V DC Sink 1746-IB32 1492-CABLE¬ H 1492-CABLE¬ H
1756 12/24V DC 10…30V DC Sink 1756-IB16 1492-CABLE¬ X 1492-CABLE¬ X
48V DC 30…60V DC Sink 1756-IC16 1492-CABLE¬ X
24V DC 10…30V DC Sink 1756-IB32 1492-CABLE¬ Z 1492-CABLE¬ Z
24V DC 10…30V DC Source 1756-IV32
1762 24V DC 14…30V DC Sink 1762-L40BWA 1492-CAB¬ A62 1492-CAB¬ A62
1762-L40BXB
1764 24V DC 14…30V DC Sink 1764-24BWA 1492-CAB¬ A64 1492-CAB¬ A64 1492-CAB¬ A64
1764-28BXB 1492-CAB¬ B64 1492-CAB¬ B64 1492-CAB¬ B64
1769 24V DC 10…30V DC Sink 1769-IQ16 1492-CAB¬ B69 1492-CAB¬ B69
1769-IQ16F
24V DC 10…30V DC Source 1769-IQ16 1492-CAB¬ B69 1492-CAB¬ B69
1769-IQ16F
24V DC 10…30V DC Sink 1769-IQ32 1492-CAB¬ J69 1492-CAB¬ J69
1771 125V DC 70…138V DC Sink 1771-IAD 1492-CABLE¬ F
24V DC 10…30V DC Sink 1771-IBD 1492-CABLE¬ F 1492-CABLE¬ F
48V DC 20…60V DC Sink 1771-ICD 1492-CABLE¬ F 1492-CABLE¬ F
24V DC 9…30V DC Sink 1771-IND 1492-CABLE¬ F 1492-CABLE¬ F
24V DC 10…30V DC Sink 1771-IBN 1492-CABLE¬ J 1492-CABLE¬ J
1794 24V DC 10…30V DC Sink 1794-IB16 1492-CABLE¬ Q
48V DC 20…60V DC Sink 1794-IC16 1492-CABLE¬ Q
24V DC 10…30V AC Sink 1794-IB32 1492-CABLE¬ Q 1492-CABLE¬ Q
24V DC 10...30V DC Source 1794-IV32 1492-CABLE¬ Q
Other DC PLC Input Modules 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ P 1492-CABLE¬ Q 1492-CABLE¬ Q
  
¬ Cables are available in standard lengths of 0.5 m, 1.0 m, and 5.0 m (1.6 ft, 3.2 ft, 16.4 ft). To order, insert the desired length code in the catalog number (“005” = 0.5 m, “010” = 1 m, “0.25” = 2.5 m “050” = 5 m). Example: 1492–CABLE005B is a 0.5m cable. Note 1492–CABLE¬ P has minimum length of 1 m.
‡ Mini patchcords are available in standard lengths of 0.9 m, 1.8 m, 3.6 m, and 6 m (3 ft, 6 ft, 12 ft, and 20 ft). To order, insert the desired length in the catalog number. Example: 889N–F4AFNU–6F represents a mini 1.8 m (6 ft) patchcord. Note catalog number reflects straight male to
straight female version with 16 AWG conductors, additional models are also available.
§ DC micro patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889D–F4ACDM–3 represents an DC micro 3 m (9.8 ft) patchcord. Note catalog number reflects straight male to straight female version with 22 AWG conductors, additional models are also available.For use with outputs, 5-pin versions may be required for earth grounding on pin 5 depending on output field device.
§ Mini-Plus patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889N–F12ACNU–2 represents a 2 m (6.5 ft) patchcord. Note catalog number reflects straight male to straight female version with 18/22 AWG conductors, additional models are also available.
Note: PNP type distribution boxes require sink type PLC inputs. NPN type require source inputs.

Table 2. DC Input Systems NEMA Type 4, Continued

    Allen-Bradley Distribution Box LEDs 5-pin DC micro, no LEDs 889D-58PT-M12
5-pin DC micro PNP, LEDs 898D-P58PT-M12
Allen-Bradley Device Patchcord 889D-F4ACDM-Ø  889D-F4ACDM-Ø 
Allen-Bradley Main Patchcord Metric 23 (12-pin)
889M-R11RMMU-Ø 
PanelConnect (16-input) 1667-16ID2206 1667-16ID2211
System  
Input System Nominal Input Range‡  Type Module Input Module    
1746 24V DC 10…30V DC Sink 1746-IB16 1492-CABLE¬ B
48V DC 30…60V DC Sink 1746-IC16 1492-CABLE¬ B
120V DC 90…146V DC Sink 1746-IH16
24V DC 10…30V DC Sink 1746-IN16 1492-CABLE¬ B
24V DC 10…30V DC Sink 1746-ITB16 1492-CABLE¬ B
24V DC 10…30V DC Source 1746-ITV16 1492-CABLE¬ B
24V DC 10…30V DC Source 1746-IV16 1492-CABLE¬ B
24V DC 10…30V DC Source 1746-IB32
24V DC 10…30V DC Source 1746-IBN
1756 12/24V DC 10…30V DC Sink 1756-IB16 1492-CABLE¬ X
48V DC 30…60V DC Sink 1756-IC16 1492-CABLE¬ X
24V DC 10…30V DC Source 1756-IB32
1764 24V DC 14…30V DC Sink 1764-24BWA 1492-CAB¬ A64 1492-CAB¬ A64
1764-28BXB 1492-CAB¬ B64 1492-CAB¬ B64
1769 24V DC 10…30V DC Sink 1769-IQ16 1492-CAB¬ B69
24V DC 10…30V DC Source 1769-IQ16 1492-CAB¬ B69
1771 125V DC 70…138V DC Sink 1771-IAD
24V DC 10…30V DC Sink 1771-IBD 1492-CABLE¬ F
48V DC 20…60V DC Sink 1771-ICD 1492-CABLE¬ F
24V DC 9…30V DC Sink 1771-IND 1492-CABLE¬ F
Other DC PLC Intput Modules 1492-CABLE¬ P 1492-CABLE¬ P
  
¬ Panel Connect to PLC I/O module cables are available in standard lengths of 0.5 m, 1.0 m, and 5.0 m. To order, insert the desired length code in the catalog number (“005” = 0.5 m, “010” = 1.0 m, “0.25” = 2.5 m, and “050” = 5 m). Example: 1492-CABLE005B is for a 0.5 m cable for the 1746-IB16 I/O module. 1492-CABLE¬ P has minimum length of 1.0 m.
‡ Refer to the PLC module installation manual for details.
§ DC micro patchcords are available in standard lengths of 1 m, 2 m, 3 m, 5 m, and 10 m (3.3 ft, 6.5 ft, 9.8 ft, 16.4 ft and 32.8 ft). To order, insert the desired length in the catalog number. Example: 889D–F4ACDM–3 represents an DC micro 3 m (9.8 ft) patchcord. Note catalog number reflects straight male to straight female version with 22 AWG conductors, additional models are also available.For use with outputs, 5-pin versions may be required for earth grounding on pin 5 depending on output field device.
Ø Replace with length of cable in meters (1 m, 2 m, 3 m, 5 m, or 10 m standard).
Note: PNP type distribution boxes require sink type PLC inputs. NPN type require source inputs.

The same information for PanelConnect NEMA Type 4 applies to PanelConnect NEMA Type 4X products as shown in Tables 1 and 2 for Cables and Distribution Boxes.

Table 3. NEMA Type 4 and 4X Input Systems

NEMA 4X Module NEMA 4 Module
1667-16IA1008X 1667-16IA1008
1667-16IA1207X 1667-16IA1207
¬  1667-16ID1001
1667-16ID1004X 1667-16ID1004
1667-16ID1201X 1667-16ID1201
¬  1667-16ID1212
¬  1667-16ID2206
¬  1667-16ID2211
¬  1667-32ID1201
¬  1667-32ID1001
  
¬ Contact factory for availability