Bulletin 1492-MC Circuit Breaker

Click to enlarge - ab_1492MCAA330_006786


Bulletin 1492-MC Circuit Breakers

Industrial Circuit Breakers for North American Applications

The Bulletin 1492-MC line includes:


Certifications

UL Listed
CSA Certified


Features


Standards Compliance for Bul. 1492-MC


Standards Compliance for GFCI
(5 mA trip sensitivity)



Standards Compliance for GFEP
(30 mA trip sensitivity)



Bulletin 1492-MC Thermal Mag. Description

Bulletin 1492-MC Circuit Breakers for Branch Circuit protection are available in one (1)-, two (2)-, and three (3)-pole construction in 120/240 volt rating, 240 volt rating and as one (1)-pole and two (2)-pole devices in 480/277 volt rating. Versions are available as Ground Fault Circuit Interrupters and as Ground Fault Equipment Protectors.

The 1492-MC product line consists of Thermal Magnetic Circuit Breakers and Ground Fault Sensing Breakers that are designed, manufactured, and certified to North American standards, UL 489, UL 943, UL1093, and the equivalent CSA standards, CSA 22.2 No. 5.1, 22.2 No. 144.


Thermal Magnetic Circuit Breakers

Bul. 1492-MC Thermal Magnetic Circuit Breakers are general-purpose devices suitable for the majority of industrial, inverse time circuit breaker applications.

They combine thermal and magnetic trip actions and provide accurate overload and short-circuit protection for conductors and connected equipment.


Circuit Breaker Application Information

Selection of a Bul. 1492-MC circuit breaker with appropriate circuit protection includes consideration of:


The following discussion is based upon National Electric Code and UL requirements. Similar considerations are appropriate for Canadian applications.

Circuit Voltage

Bul. 1492-MC circuit breakers are rated by voltage class. Applications should not exceed the listed voltage range (see Table 1).

Circuit Frequency

Bul. 1492-MC circuit breakers may be applied to frequencies from DC up to 60 Hz without derating. For applications above 60…400 Hz, contact Rockwell Automation with specific application information for the derating of the circuit breakers.

Available Short Circuit Current

Bul. 1492-MC circuit breakers should only be applied in those applications in which the available short-circuit (or fault) current is less than or equal to the interrupting rating shown in the Voltage and Interrupting Ratings table.

Table 1. Voltage and Interrupting Ratings

AC Voltage DC Voltage ¬  Interrupting Ratings (rms Symmetrical Amperes) Cat. No.
AC Rating DC Rating ¬ 
120/240 24, 48, 62.5 10,000 3,000 1492-MCAA1xx
1492-MCAA2xx
240 24, 48, 62.5 3,000 1492-MCAA2Hxx
1492-MCAA3xx
120/240 T  T  1492-MCBA1xx
1492-MCBA2xx
240 T  T  1492-MCBA2Hxx
1492-MCBA3xx
120 T  10,000 T  1492-MCEA1xx
120/240 1492-MCEA2xx
120 1492-MCGA1xx
120/240 1492-MCGA2xx
  
¬ Rating as supplementary protector.
T Consult your local Rockwell Automation sales office or Allen-Bradley distributor for specific rating.

Continuous Current Rating

Bul. 1492-MC circuit breakers are rated in RMS amperes at a 40 °C (104 °F) ambient temperature per UL 489 (CSA 22.2 No. 5.1). This temperature is generally used as the average temperature within an industrial enclosure. If a circuit breaker is applied in a temperature that exceeds the 40 °C (104 °F) ambient, then the circuit breaker should be derated. Contact your local Rockwell Automation sales office or Allen-Bradley distributor for derating information.

The characteristic trip curves are shown on pages . The trip bands shown for each breaker represent current tripping limits for a circuit breaker and are within the limits established by UL. For a specific current at 40 °C (104 °F), a circuit breaker will open ("clear the circuit") automatically at some total time that will be within the "Minimum" and "Maximum" time shown as the "Minimum" and "Maximum" curves. For example, page shows that a one pole, 15 A, 1492-MC trips in not less than 10 s and not more than 150 s on a 30 A current. Because the UL standard defines this time spread, users should not specify exact tripping time. The lower current portion of the curves (upper left) depict the time to trip due to thermal action and reflect overload protection of the wire and connect load. The higher current portion of the curves (lower right) depicts the trip due to magnetic action of the circuit breaker and reflects protection due to short circuit level currents.

Standard current ratings are, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80, 90, and 100 A.


Application Considerations

The selection of a specific ampere rating for a specific application is dependent on the type of load and duty cycle and is governed by the National Electric Code (Canadian Electric Code) and UL/CSA. In general the codes require that overcurrent protection is at the current supply and at points where wire sizes are reduced. In addition the codes state that conductors be protected according to their current carrying capacity. There are specific situations that require application consideration, such as motor circuit, and guidelines for the selection for transformer protection.

Bulletin 1492-MC circuit breakders are "non-100% rated" as defined by UL 489 Part 7.1.4.2. As such the circuit breaker's rating should be loaded to no more than 80%, if used with continuous loads.


Branch Circuits:

Bulletin 1492-MC circuit breakers may be used to protect branch circuits. A branch circuit is the wiring portion of a system extending beyond the final overcurrent device protecting the circuit.

Guidelines established in NEC, CEC, UL, and CSA should be used to determine the specific device. For example:



1) Motor Branch Circuit

Bulletin 1492-MC circuit breakers are not horsepower rated because they are able to safely interrupt currents far in excess of the locked rotor value for a selected motor. This ability is recognized in the codes and standards and is also established by the UL and CSA tests described in UL 489 and CSA C22.2 No. 5.1 standards.

The size of a Bulletin 1492-MC circuit breaker should be determined following the guidelines for an Inverse Time Circuit Breaker.

References: NEC 430.51 and UL 508A. Also see CEC and appropriate Canadian Standards.



2) Transformer Protection

Bulletin 1492-MC circuit breakers may be used for transformer protection following the guidelines established.

References: NEC 450 and UL 508A. Also see CEC and appropriate Canadian Standards.



3) Heater Load, Lighting, and Other Load Protection

Bulletin 1492-MC circuit breakers may be used for protection of heater loads, lighting loads, and other loads following the guidelines established.

References: NEC Article 31 and UL 508A. Also see CEC and appropriate Canadian Standards.



Coordinated Overcurrent Protection

Where an orderly shutdown is required to minimize the hazards to personnel and equipment, a system of coordination based upon the faulted or overloaded circuit is isolated by selective operation of only the overcurrent protective device closest to the overcurrent condition.

The user should select devices that meet this requirement.

References: NEC 240.12. Also see CEC.


Time Current Curve – 1-Pole Circuit Breaker

Click to enlarge - 1_Pole_TripCurve


Time Current Curve – 2-Pole Circuit Breakers

Click to enlarge - 2_Pole_TripCurve


Time Current Curve – 3-Pole Circuit Breakers

Click to enlarge - 3_Pole_TripCurve

1492-MC Cat. No. Explanation

1492-MC   A A 1 15
      a b c d

a
Body Style
Code Description
A 1/2 in. wide/pole (DIN Rail mounting)
B 1 in. wide/pole (DIN Rail mounting)
E GFEP (30 mA)
G GFCI (5 mA)

b
Interrupt Rating
Code Description
A 10 kA AIC

c
Poles
Code Description
1 1 Pole
2 2 Poles
2H 2 Poles (240V AC)
3 3 Poles

d
Current Rating Size
Code Description Code Description
10 10 A 50 50 A
15 15 A 55 55 A
20 20 A 60 60 A
25 25 A 70 70 A
30 30 A 80 80 A
35 35 A 90 90 A
40 40 A A0 100 A
45 45 A    

Bul. 1492-MC Thermal Magnetic Product Selection

120/240 and 240V AC DIN Rail Mounting

120/240 and 240V AC DIN Rail Mounting
Continuous Ampere
Rating @ 40°C (104°F)
Width [in.] Cat. No. Width [in.] Cat. No.
120/240V AC 240V AC
1 pole 2 poles 2 poles 3 poles
10 1/2 1492-MCAA110 1492-MCAA210
15 1/2 1492-MCAA115 1492-MCAA215 1/2 1492-MCAA2H15 1492-MCAA315
20 1/2 1492-MCAA120 1492-MCAA220 1/2 1492-MCAA2H20 1492-MCAA320
25 1/2 1492-MCAA125 1492-MCAA225 1/2 1492-MCAA2H25 1492-MCAA325
30 1/2 1492-MCAA130 1492-MCAA230 1/2 1492-MCAA2H30 1492-MCAA330
35 1/2 1492-MCAA135 1492-MCAA235 1 1492-MCBA2H35 1492-MCBA335
40 1/2 1492-MCAA140 1492-MCAA240 1 1492-MCBA2H40 1492-MCBA340
45 1/2 1492-MCAA145 1492-MCAA245 1 1492-MCBA2H45 1492-MCBA345
50 1/2 1492-MCAA150 1492-MCAA250 1 1492-MCBA2H50 1492-MCBA350
55 1/2 1492-MCAA155 1492-MCAA255 1 1492-MCBA2H55 1492-MCBA355
60 1/2 1492-MCAA160 1492-MCAA260 1 1492-MCBA2H60 1492-MCBA360
70 1 1492-MCBA170 1492-MCBA270 1 1492-MCBA2H70 1492-MCBA370
80 1 1492-MCBA180 1492-MCBA280 1 1492-MCBA2H80 1492-MCBA380
90 1 1492-MCBA190 1492-MCBA290 1 1492-MCBA2H90 1492-MCBA390
100 1 1492-MCBA1A0 1492-MCBA2A0 1 1492-MCBA2HA0 1492-MCBA3A0
  

1492-MC Ground Fault Sensing

The Bulletin 1492-MC Circuit Breakers with Ground Fault protection for Branch Circuits are available in 1- and 2-pole construction in 120/240V rating. Versions are available as Ground Fault Circuit Interrupters and as Ground Fault Equipment Protectors.

When protection from low-level fault currents for North American standards is required, two versions of protection are available.



The following devices are tested and listed to meet the North American standards of UL 489, UL 943 (for GFCI), UL1053 (for GFEP), and CSA 22.2 No.5.1.

It is recommended that the devices be tested monthly by using the TEST button to check for proper operation of the device.


Bul. 1492-MC Ground Sensing Product Selection

    Cat. No. Cat. No.
Continuous Ampere Rating @ 40 °C (104 °F) [A] 120V AC 120/240V AC
    1 Pole 2 Pole
Click to enlarge - 1492_MCGA115-10302 GFCI (5 mA Sensitivity)
15 1492-MCGA115 1492-MCGA215
20 1492-MCGA120 1492-MCGA220
25 1492-MCGA125 1492-MCGA225
30 1492-MCGA130 1492-MCGA230
40 1492-MCGA140 1492-MCGA240
50 1492-MCGA250
GFEP (30 mA Sensitivity)
15 1492-MCEA115 1492-MCEA215
20 1492-MCEA120 1492-MCEA220
25 1492-MCEA125 1492-MCEA225
30 1492-MCEA130 1492-MCEA230
40 1492-MCEA140 1492-MCEA240
50 1492-MCEA250
  For panel mounting use two 1492-AMCP1 per device
For DIN Rail mounting use one 1492-AMCDIN1 per pole
  

Auxiliary Devices

Device description 1 pole 2 and 3 poles
Locking Attachment for Circuit Breaker 1492-MCAAxxx 1492-AMCAL1 1492-AMCALM
1492-MCBAxxx 1492-AMCBL1
Finger protection cover for 1 in. wide Cat. No. 1492‑MCBxxx, package of 10 (one required
for line and one required for load for each pole) (not for GFCI / GFEP)
1492-AMCBFP
DIN Rail adapter, per pole, DIN Rail mounting for GFCI, GFEP 1492-AMCDIN1
Panel Mounting Clips for GFCI and GFEP, two required per device 1492-AMCP1
  

Specifications

Standards Compliance UL 489, CSA C22.2 No. 5.1
Certifications UL Listed, CSA Certified
Rated Voltage 120/240V AC, 240V AC
Continuous Current rating @ 40°C (104°F) 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 70, 80 90, 100 Amp
Rated short circuit capability 10 kA 120/240V AC and 240V AC 14 kA 480Y/277V AC
Degree of protection Open Device 1/2 in. wide circuit breakers are finger safe from front per IEC. Terminal Covers available for 1 in. wide circuit breaker at 120/240 and 240V AC.
Mounting DIN Rail (check product for specific)
Operating Temperature 0…60°C (32...140°F) (non-condensing)
Shipment and short term storage limits -40°C…+80°C (-40...176°F)
Wire Size See Terminal Table
Terminal Torque See Terminal Table
Recommended Wire Strip Length See Terminal Table
  

Terminals

Cat. No. Continuous Current Rating Wire Type Wire Range [AWG] Terminal Torque Line Strip Length Line and Load Terminals
1492-MCAAxxx 10…60 A Copper (Cu) 14…10 20 lb•in.
(2.3 N•m)
7/16 in. Click to enlarge - 1492-MC_terminals-A
8 25 lb•in.
(2.8 N•m)
6…4 27 lb•in.
(3.0 N•m)
1492-MCBAxxx 35…60 A 14…10 20 lb•in.
(2.3 N•m)
1/8 in. Allen Head
8…4 32 lb•in.
(3.6 N•m)
Click to enlarge - 1492-MC_terminals-C1
70…100 A 4…1/0 50 lb•in.
(5.6 N•m)
1492-MCEAxxx 15…50 A 14…10 20 lb•in
(2.3 N•m)
9/16 in. Line
8 25 lb•in
(2.8 N•m)
Click to enlarge - 1492-MC_terminals-F
1492-MCGAxxx 6…4 27 lb•in
(3.0 N•m)
Load
Click to enlarge - 1492-MC_terminals-A
  

1492-MC Approximate Dimensions

Note: Dimensions are shown in inches (millimeters). Dimensions are not intended for manufacturing purposes.


Catalog Type No. of Poles Continuous Current Rating [A] Width [in.]
1492-MCAA1xx 1 10…60 0.490
1492-MCAA2xx 2 10…60 0.980
1492-MCAA2Hxx 2 15…30 0.980
1492-MCAA3xx 3 15…30 1.470
1492-MCBA1xx 1 70...100 1.000
1492-MCBA2xx 2 70...100 2.000
1492-MCBA2Hxx 2 35...100 2.000
1492-MCBA3xx 3 35...100 3.000
1492-MCEA1xx 1 15...50 0.990
1492-MCEA2xx 2 15...50 1.980
1492-MCGA1xx 1 15...50 0.990
1492-MCGA2xx 2 15...50 1.980
  

1492-MCAAnxx

Click to enlarge - 1492mcaa1xxx


1492-MCEA1xx
1492-MCGA1xx


Click to enlarge - 1492mcea1xx_dim


1492-MCEA2xx
1492-MCGA2xx


Click to enlarge - 1492mcea2xx_dim3


1492-MCBAxxx

Click to enlarge - 1492-MCBAxxx_dims