Bulletin 100L Lighting Contactors

Click to enlarge - 100L-76-1a


Click to enlarge - 100L-76-2


Bulletin 100L Electrically Held Lighting Contactors


Bulletin 100L lighting contactors have been designed to control a variety of lighting loads. The product offering includes 4-, 8-, and 12-pole contactors with or without enclosures. The Bulletin 100L line of lighting contactors has been designed with a 20 A rating for all popular lighting loads and other non-motor applications including tungsten filament lighting loads, electric discharge (fluorescent) loads, electric furnaces, and electric water heaters. In addition these contactors have been designed to meet the requirements of both CSA and UL.

Standards Compliance and Certifications

Standards Compliance

CSA C22.2, No. 14
UL 508
Meets the material restrictions for European Directive 2002/95/IEC-EU-RoHS


Certifications

CE Marked
cULus Listed (File No. E14843; Guide NRNT, NRNT7)


Your order must include: cat. no. of the contactor specified with coil voltage code and, if required, cat. no. of any accessories

Product Selection

Enclosure Type Rating No. of Poles★  Cat. No.
Open 4 100L-C20NÄ4
8 100L-C20NÄ8
12 100L-C20NÄ12
IP42 (Type 1) (with lift-off cover) 4 100L-C20AÄ4
8 100L-C20AÄ8
12 100L-C20AÄ12
IP66 (Type 3/4/12) (with hinged cover) 4 100L-C20FÄ4
8 100L-C20FÄ8
12 100L-C20FÄ12
  
★ These contactors do not include an auxiliary hold-in contact. If a hold-in contact is required it can be ordered by adding a suffix -90 to the cat. no. Example: Cat. No. 100L-C20NJ4-90.

Ä Coil Voltage Code

The cat. no. as listed is incomplete. To complete the cat. no., select a coil voltage code from the chart below and insert into the cat. no. Example: Cat. No. 100L-C20NÄ4 becomes Cat. No. 100L-C20NJ4. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.

  [V] 24 48 110 120 208 220 240 277 347 380…
400
415 440 480 500 600
AC, 50Hz K Y D P A T N G B M
AC, 60Hz J X D H L A T I N B C
  

Modifications

Full Voltage Non-Reversing Starters and Lighting Contactors (Bulletins 100L)

Listed on this and the following pages are factory-installed modifications and special features which are available for the low voltage (600V maximum) starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product Cat. No. and add the price addition to the base price. Example: Cat. No. 100L-C09ADA1E-1

Description of Modification Suffix Code Enclosure Design C09 C12 C16 100L-C20 C23 C30 C37 C43 C60 C72 C85
START-STOP Push Button 1 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Metal Lift-off A A A NA A A A A A A A
Metal Hinged A A A NA A A A A A A A
ON-OFF Push Button 1E Plastic Lift-off A A A NA A NA NA NA NA NA NA
Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
HAND-OFF-AUTO Selector Switch 3 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
OFF-ON Selector Switch 3E Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Red Pilot Light★  4R Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Red LED Pilot Light (120V) 4R1 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Red LED Pilot Light (240V) 4R2 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Control Circuit Transformer 2 Primary and 1 Secondary Fuse Provided (Standard Capacity) 6P‡  Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
External Reset 7 Plastic Lift-off A A A NA A NA NA NA NA NA NA
Metal Lift-off A A A NA A A A A A A A
Metal Hinged A A A NA A A A A A A A
Control Circuit Fuse Block 2 Fuses Provided 22 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor (100L only) 90 Metal Lift-off NA NA NA A NA NA NA NA NA NA NA
Metal Hinged NA NA NA A NA NA NA NA NA NA NA
Additional 1 N.O. – 1 N.C. (Side Mount) Auxiliary Contact on Contactor 901 Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
Additional 1 N.O. – 1 N.C. (Front Mount) Auxiliary Contact on Contactor 901T Metal Lift-off A A A A A A A A A A A
Metal Hinged A A A A A A A A A A A
  

Specifications

Ratings

Type of Load Max. Current [A] Max. AC Volts, Poles to Load‡ 
1 for 1Æ 3 for 3Æ
Tungsten 20 277 480Y/277V
15 347 600Y/347V
Ballast 20 277 480Y/277V
15 347 600Y/347V
General Use
Resistance Heating
30 600 600
  
‡ 20 A, 250V DC max. with 3 poles in series.

Wiring Diagrams

Click to enlarge - 100L-76-3


Click to enlarge - 100L-76-4


Click to enlarge - 100L-76-5

Approximate Dimensions

Dimensions are shown in millimeters (inches). Dimensions are not intended for manufacturing purposes.

Open Type

Click to enlarge - 100L-126-1


Click to enlarge - 100L-126-2


IP42 (Type 1)

Cat. No. A
Wide
B
High
C
Deep
D E F
100L-C20AÄ4 140
(5-1/2)
220
(8-21/32)
152
(5-31/32)
175
(6-7/8)
95
(3-3/4)
22.5
(7/8)
100L-C20AÄ8 235
(9-1/4)
220
(8-21/32)
152
(5-31/32)
175
(6-7/8)
190
(7-1/2)
22.5
(7/8)
100L-C20AÄ12 270
(10-5/8)
290
(11-7/16)
152
(5-31/32)
245
(9-21/32)
225
(8-7/8)
22.5
(7/8)
  

Click to enlarge - 100L-126-3


IP66 (Type 3/4/12)

Click to enlarge - 100L-126-4


Cat. No. A
Wide
B
High
C
Deep
D E F G H J K
100L-C20FÄ4 200
(7-7/8)
300
(11-13/16)
160
(6-5/16)
236
(9-9/32)
76
(3)
62
(2-7/8)
17.5
(11/16)
313
(12-5/16)
105
(4-1/8)
47.5
(1-7/8)
100L-C20FÄ8 250
(9-27/32)
250
(9-27/32)
160
(6-5/16)
186
(7-5/16)
76
(3)
87
(3-7/16)
17.5
(11/16)
263
(10-3/8)
105
(4-1/8)
72.5
(2-7/8)
100L-C20FÄ12 300
(11-13/16)
300
(11-13/16)
160
(6-5/16)
236
(9-9/32)
76
(3)
61
(2-13/32)
17.5
(11/16)
313
(12-5/16)
206
(8-1/8)
47
(1-27/32)