Bulletin 500LC AC Mechanically Held Lighting Contactors

Product Overview


Click to enlarge - 500LC-1200A1_4c


Bulletin 500LC AC Mechanically Held Lighting Contactors


The Allen-Bradley Bulletin 500LC lighting contactors are available up to 12 poles. The Bulletin 500LC line is of shallow construction to accommodate mounting in panelboards or separate mounting.

Standards Compliance and Certifications

Standards Compliance

UL 508
CSA C22.2, No. 14


Certifications

UL Listed (File No. E14843; Guide No. NRNT)
CSA Certified (File No. LR1234)


Product Selection

Build a Catalog Number


No. of Poles Open-Type
without Enclosure
Type 1
Surface Mount
Type 12
Surface Mount
Type 3R
Surface Mount
Type 4/4X
Stainless Steel
Surface Mount
N.O. N.C. Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
2 2 500LC-220Ä 500LC-22AÄ 500LC-22FÄ 500LC-22NÄ 500LC-22CÄ
3 3 500LC-330Ä 500LC-33AÄ 500LC-33FÄ 500LC-33NÄ 500LC-33CÄ
4 4 500LC-440Ä 500LC-44AÄ 500LC-44FÄ 500LC-44NÄ 500LC-44CÄ
6 6 500LC-660Ä 500LC-66AÄ 500LC-66FÄ 500LC-66NÄ 500LC-66CÄ
2 0 500LC-200Ä 500LC-20AÄ 500LC-20FÄ 500LC-20NÄ 500LC-20CÄ
3 0 500LC-300Ä 500LC-30AÄ 500LC-30FÄ 500LC-30NÄ 500LC-30CÄ
4 0 500LC-400Ä 500LC-40AÄ 500LC-40FÄ 500LC-40NÄ 500LC-40CÄ
6 0 500LC-600Ä 500LC-60AÄ 500LC-60FÄ 500LC-60NÄ 500LC-60CÄ
8 0 500LC-800Ä 500LC-80AÄ 500LC-80FÄ 500LC-80NÄ 500LC-80CÄ
10 0 500LC-1000Ä 500LC-100AÄ 500LC-100FÄ 500LC-100NÄ 500LC-100CÄ
12 0 500LC-1200Ä 500LC-120AÄ 500LC-120FÄ 500LC-120NÄ 500LC-120CÄ
  

Enclosed Panels

Description NEMA Type Cat. No.‡ 
Mechanically-held, 2-wire control contactor, timing relay, 12 N.O. poles 1 500LC-120AA1-M2120-3E-4R-441
Mechanically-held, 2-wire control contactor, timing relay, 12 N.O. poles 12 500LC-120FA1-M2120-3E-4R-441
Mechanically-held, 2-wire control contactor, Pico GFX controller, 12 N.O. poles 1 500LC-120AA1-M2120-4R-436
Mechanically-held, 2-wire control contactor, Pico GFX controller, 12 N.O. poles 12 500LC-120FA1-M2120-4R-436
  
‡ For enclosed control lighting panels not listed, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 500LC-220Ä becomes Cat. No. 500LC-220A1.

  [V] 110…120 208…240 265…277
AC, 50/60 Hz A1 A2 A3
  

Accessories — Field Installed

Click to enlarge - 500LC_AuxContact Description Current Rating Cat. No.
One Form C (SPDT)
Auxiliary contact rated 10 A at 277V AC to indicate status of main contacts.
500LC-141C
Cat. No. 500LC-141C Two Form C (SPDT)
Auxiliary contact rated 10 A at 277V AC to indicate status of main contacts.
500LC-142C
Click to enlarge - 500LC_CtrlMod_2Wire Solid-state control module for 2-wire control. 12V AC/DC 500LC-47CM12
24V AC/DC 500LC-47CM24
120V AC 500LC-47CM120
Cat. No. 500LC-47CM120 240/277V AC 500LC-47CM240
Click to enlarge - 500LC_CtrlMod_3Wire Solid-state control module for 3-wire control. 12V AC/DC 500LC-48CM12
24V AC/DC 500LC-48CM24
120V AC 500LC-48CM120
Cat. No. 500LC-48CM120 240/277V AC 500LC-48CM240
Click to enlarge - 500LC_CtrlMod_StartStop Solid-state control module for stop/start control (Form 3). 12V AC/DC 500LC-49SS12
24V AC/DC 500LC-49SS24
120V AC 500LC-49SS120
Cat. No. 500LC-49SS120 240/277V AC 500LC-49SS240
Click to enlarge - 500LC_CoilConvKit Coil conversion kit 110…120V AC 500LC-CCKA1
208…240V AC 500LC-CCKA2
Cat. No. 500LC-CCKA1 265…277V AC 500LC-CCKA3
Click to enlarge - 500LC-CRKA1_GS Coil replacement kit 110…120V AC 500LC-CRKA1
208…240V AC 500LC-CRKA2
Cat. No. 500LC-CRKA1 265…277V AC 500LC-CRKA3
Click to enlarge - 500LC_PoleConv Description No. of Poles Cat. No.
Pole conversion kit 1-Pole N.O. 500LC-2PCK
4-Pole N.O. 500LC-4PCK
Cat. No. 500LC-4PCK 6-Pole N.O. 500LC-6PCK
Click to enlarge - 500LC_EncwithCover Description Enclosure Type Cat. No.
Enclosure Type 1 surface mount 500LC-E1SM
Type 12 surface mount 500LC-E12SM
Type 4/4X stainless steel surface mount 500LC-E4SM
Cat. No. 500LC-E1SM Type 3R surface mount 500LC-E3RSM
Click to enlarge - 500LG_frontinside_GS Description Enclosure Type Enclosures Subpanel§ 
Cat. No.
Enclosure Type 1 lift off 598-BA12105
Type 1 flush mount 598-QA12106
Type 1 hinged 598-DA12106 598-PA1210
‡  598-DA14126 598-PA1412
‡  598-DA16166 598-PA1616
Type 12 hinged 598-DF12106 598-PC1210
‡  598-DF14126 598-PC1412
‡  598-DF16146 598-PC1614
Type 4/12 hinged 598-DJ12106 598-PC1210
‡  598-DJ14126 598-PC1412
‡  598-DJ16146 598-PC1614
Type 4/4X hinged 598-DC12106 598-PC1210
‡  598-DC14126 598-PC1412
Cat. No. 598-DF14126 ‡  598-DC16146 598-PC1614
  
‡  Three 22.5 mm pre-punched pilot holes are available as standard enclosure. Cat. No. 800F-N2 hole plug, sold separately.
§  Subpanel sold separately.

Specifications


Inrush Current/Minimum Control Line Fuse♣ ∆ 

Amps Inrush Current and Fuse Size
[Amps rms] at AC Control Voltage
120V 240V 277V
Inrush 5.0 2.5 2.2
Fuse 2.0 1.0 1.0
  
♣ The minimum permissable control circuit fuse size is based on the operating coil's momentary inrush current.
∆ Overcurrent protective device ratings for control circuits should be selected in accordance with applicable electrical codes.

Maximum AC Voltage and Amp. Ratings
For Bulletin 500LC Main Contacts (Open or Closed)


Load
Type
Amperes
Continuous [A]
Poles to Load
1 for 1-Phase 2 for 1-Phase
3 for 3-Phase
Tungsten 20 250V AC 250V AC
Ballast 20 347V AC 600V AC
General 30 347V AC 600V AC
  

Maximum DC Voltage and Amp. Ratings
For Bulletin 500LC Main Contacts (Open or Closed)


Load
Type
Amperes
Continuous [A]
Poles to Load
2 in Series 3 in Series
General 20 125V DC 250V DC
  

Withstand Current Rating

Available Symmetrical Amperes RMS
At AC Service Voltage When Used with Molded-Case Circuit Breakers contained in UL67 listed panelboards
Withstand Current Rating [A] Maximum Breaker Size [A]
250V
480V
600V
22 000
14 000
10 000
30
30
30
  

Control Line Run

Wire Size
[AWG]
Maximum Distance [ft] at AC Control Voltage
120V 240V 277V
14 700 2000 2600
12 1050 3100 4100
10 1670 5000 6600
  

Ratings for Control Modules

Control Voltage Range: 80…125% of nominal

Ambient Temperature Range (Operate): –40…+60 °C (–40…+140 °F)

Ambient Temperature Range (Storage): –40…+60 °C (–40…+140 °F)


Control Module Cat. No.
500LC–47CM*
Cat. No.
500LC–48CM*
Cat. No.
500LC–49SS*
AC DC AC DC AC DC
12V AC/DC 0.60 0.32 0.34 0.36 0.68 0.70
24V AC/DC 0.85 0.36 0.34 0.38 0.70 0.72
120V AC 1.90 1.60 3.70
240/277V AC 4.00 2.50 6.00
  

Modifications — Factory Installed

For use on Bul. 500LC Mechanically Held and Bul. 500LG Electrically Held Lighting Contactors

Listed on this and the following pages are factory installed modifications and special features which are available for Bulletin 500LC and 500LG lighting contactors listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product cat. no. Example: Cat. No. 500LC-120CA1-1.

Description of Modification Suffix No. Enclosure Type
Pilot Devices in Cover or Flange    
    START-STOP Push Button 1 1, 3R, 4/4X, 12
    ON-OFF Push Button 1E
    HAND-OFF-AUTO Selector Switch 3
    OFF-ON Selector Switch 3E
Pilot Light Incandescent Bulb 4★ 
LED Bulb 4L★ 
Push-to-Test Pilot Light Incandescent Bulb 5★ 
LED Bulb 5L★ 
Control Circuit Transformer    
Includes 2 primary fuse and 1 secondary fuse
    with standard capacity 50/60 Hz
6P 1, 3R, 4/4X, 12
    with 100 W extra capacity 50/60 Hz 6XP
Control Circuit    
    Auxiliary contact installed on contactor N.O. 90 1, 3R, 4/4X, 12
N.C. 91
    Fused control circuit for applications less transformer 1 fuse — Fuse included 21
2 fuses — Fuses included 22
Terminal block 12-point block TB12
Two-wire solid state control module (used on Bulletin 500LC only)    
    12…24V DC control M212 1, 3R, 4/4X, 12
    24V AC control M224
    120V AC control M2120
Three-wire solid state control module (used on Bulletin 500LC only)    
    12…24V DC control M312 1, 3R, 4/4X, 12
    24V AC control M324
    120V AC control M3120
    277V AC control M3277
START-STOP solid state control module (used on Bulletin 500LC only)    
    12…24V DC control M5512 1, 3R, 4/4X, 12
    24V AC control M5524
    120V AC control M55120
    240/277V AC control M55240
HAND-OFF-AUTO selector switch with key 3K
ON-OFF-AUTO selector switch 3F
Other Modifications    
Lightning Arrestor 427 1, 3R, 4/4X, 12
Pico controller with LCD display and key pad
    24-hour time clock
    24-hour time clock with day ommission
    7-day time clock
    Automatic adjustment for day light savings time
436
Multi-function Bulletin 700-FSM timing relay (0.05 s…60 h) 437
Bulletin 700-HNC miniature timer (0.1 s…10 h) 438
Bulletin 700-HR dial timing relay (0.05 s…300 h) 440
Bulletin 700-HX digital timer with LCD display 441
  
★ The suffix number is incomplete. Specify the lens with the following letters: A = Amber; B = Blue; C = Clear; G = Green; W = White

Approximate Dimensions

Open Type Dimensions

Dimensions are shown in inches (mm). Dimensions are not intended for manufacturing purposes.


Click to enlarge - 500LC_OpenTypeDim


Dimensions are shown in inches (mm). Dimensions are not intended for manufacturing purposes.


Type 3R, Surface Mount 4/4X (Stainless Steel), and 12 Enclosure

Click to enlarge - 500LC_12_4X_3R


Type 1 Enclosure (Flush mount for Bulletin 500LC only)

Approximate Shipping Weights§ 

Poles Open Enclosed
2…6 2 lbs.
(0.91 kg)
9 lbs.
(4.08 kg)
8…12 2.7 lbs.
(1.2 kg)
9.7 lbs.
(4.4 kg)
2…6
(with Acc. 47, 48, or 49)
2.3 lbs.
(1.05 kg)
9.3 lbs.
(4.22 kg)
8…12
(with Acc. 47, 48, or 49)
3.0 lbs.
(1.36 kg)
10.0 lbs
(4.54 kg)
  
§ Not including shipping carton.

Dimensions are shown in inches (mm). Dimensions are not intended for manufacturing purposes.


Click to enlarge - 500LC_EnclosedTypeDim


Dimensions are shown in inches (mm). Dimensions are not intended for manufacturing purposes.


Click to enlarge - 500LG-LC_Dim


NEMA Type Cat. No. Approximate Dimensions in Inches (mm)
A (Height) B (Width) C (Depth) D E (Working Depth) F (Hasp) G
12 598-DF14126 14 (355.6) 12 (304.8) 6.27 (159.3) 10 (254.0) 5.53 (140.5) 7.06 (179.3)
1 598-DA14126 14 (355.6) 12 (304.8) 6.08 (154.4) 1.50 (38.1) 5.5 (139.7) 6.24 (158.5) 0.50 (12.7)