Catalogs > Industrial Controls Catalog > Lighting Control > Multi-Pole Lighting Contactors > Bulletin 500LG Electrically and Mechanically Held Lighting Contactors
Bulletin 500LG Electrically and Mechanically Held Lighting Contactors
| Introduction | Standards Compliance and Certifications | Catalog Number Explanation | Product Selection | Accessories — Field Installed |
| Modifications — Factory Installed | Wiring Diagrams | Specifications | Approximate Dimensions |
| Build a Catalog Number |
| No. of Poles | Open-Type without Enclosure |
No. of Poles | Open-Type without Enclosure |
No. of Poles | Open-Type without Enclosure |
|||||
| N.O. | N.C. | Cat. No. | N.O. | N.C. | Cat. No. | N.O. | N.C. | Cat. No. | ||
| 0 | 2 | 500LG-020Ä-µ | 3 | 0 | 500LG-300Ä-µ | 6 | 0 | 500LG-600Ä-µ | ||
| 3 | 500LG-030Ä-µ | 1 | 500LG-310Ä-µ | 1 | 500LG-610Ä-µ | |||||
| 4 | 500LG-040Ä-µ | 2 | 500LG-320Ä-µ | 2 | 500LG-620Ä-µ | |||||
| 5 | 500LG-050Ä-µ | 3 | 500LG-330Ä-µ | 3 | 500LG-630Ä-µ | |||||
| 6 | 500LG-060Ä-µ | 4 | 500LG-340Ä-µ | 4 | 500LG-640Ä-µ | |||||
| 7 | 500LG-070Ä-µ | 5 | 500LG-350Ä-µ | 5 | 500LG-650Ä-µ | |||||
| 8 | 500LG-080Ä-µ | 6 | 500LG-360Ä-µ | 6 | 500LG-660Ä-µ | |||||
| 1 | 1 | 500LG-110Ä-µ | 7 | 500LG-370Ä-µ | 7 | 0 | 500LG-700Ä-µ | |||
| 2 | 500LG-120Ä-µ | 8 | 500LG-380Ä-µ | 1 | 500LG-710Ä-µ | |||||
| 3 | 500LG-130Ä-µ | 4 | 0 | 500LG-400Ä-µ | 2 | 500LG-720Ä-µ | ||||
| 4 | 500LG-140Ä-µ | 1 | 500LG-410Ä-µ | 3 | 500LG-730Ä-µ | |||||
| 5 | 500LG-150Ä-µ | 2 | 500LG-420Ä-µ | 4 | 500LG-740Ä-µ | |||||
| 6 | 500LG-160Ä-µ | 3 | 500LG-430Ä-µ | 8 | 0 | 500LG-800Ä-µ | ||||
| 7 | 500LG-170Ä-µ | 4 | 500LG-440Ä-µ | 1 | 500LG-810Ä-µ | |||||
| 8 | 500LG-180Ä-µ | 5 | 500LG-450Ä-µ | 2 | 500LG-820Ä-µ | |||||
| 2 | 0 | 500LG-200Ä-µ | 6 | 500LG-460Ä-µ | 3 | 500LG-830Ä-µ | ||||
| 1 | 500LG-210Ä-µ | 7 | 500LG-470Ä-µ | 4 | 500LG-840Ä-µ | |||||
| 2 | 500LG-220Ä-µ | 8 | 500LG-480Ä-µ | 9 | 0 | 500LG-900Ä-µ | ||||
| 3 | 500LG-230Ä-µ | 5 | 0 | 500LG-500Ä-µ | 1 | 500LG-910Ä-µ | ||||
| 4 | 500LG-240Ä-µ | 1 | 500LG-510Ä-µ | 2 | 500LG-920Ä-µ | |||||
| 5 | 500LG-250Ä-µ | 2 | 500LG-520Ä-µ | 10 | 0 | 500LG-1000Ä-µ | ||||
| 6 | 500LG-260Ä-µ | 3 | 500LG-530Ä-µ | 1 | 500LG-1010Ä-µ | |||||
| 7 | 500LG-270Ä-µ | 4 | 500LG-540Ä-µ | 2 | 500LG-1020Ä-µ | |||||
| 8 | 500LG-280Ä-µ | 5 | 500LG-550Ä-µ | 11 | 0 | 500LG-1100Ä-µ | ||||
| 6 | 500LG-560Ä-µ | 12 | 0 | 500LG-1200Ä-µ | ||||||
Enclosed Panels§
| Description | NEMA Type | Cat. No. |
| Electrically-held panel, timing relay, 12 poles | 1 | 500LG-120AA1-E-3E-4R-441 |
| Electrically-held panel, timing relay, 12 poles | 12 | 500LG-120FA1-E-3E-4R-441 |
| Electrically-held panel, Pico GFX controller, 12 poles | 1 | 500LG-120AA1-E-4R-436 |
| Electrically-held panel, Pico GFX controller, 12 poles | 12 | 500LG-120FA1-E-4R-436 |
| For enclosed control lighting panels not listed, please contact your local Rockwell Automation sales office or Allen-Bradley distributor. | ||
| § A 500LG lighting control panel configured with electrically-held contactors can be field converted with mechanically-held contactors by installing a control module conversion kit. | ||
Ä µ Coil Voltage and Control Type Suffix Codes
The cat. no. as listed, is incomplete. Select a Coil Voltage suffix code and a Control Type suffix code from the tables below to complete the cat. no. Example: For a 120V (60 Hz) coil, mechanically held contactor with a 3-wire, 24V DC control module, Cat. No. 500LG-220Ä-µ becomes Cat. No. 500LG-220A1-M312.
| Ä Voltage [V AC] | 115…120 (60 Hz) 110 (50 Hz) |
230…240 (60 Hz) 220 (50 Hz) |
277 (60 Hz) 240 (50 Hz) |
347 (60 Hz) | 460…480 (60 Hz) 440 (50 Hz) |
575…600 (60 Hz) 550 (50 Hz) |
| Coil Code | A1 | A2 | A3 | A4 | A5 | A6 |
| µ Type | Electrically held | Mechanically held 2-wire 12…24V DC |
Mechanically held 2-wire 24V AC |
Mechanically held 2-wire 120V AC |
Mechanically held 2-wire 277V AC |
Mechanically held 3-wire 12…24V DC |
Mechanically held 3-wire 24V AC |
Mechanically held 3-wire 120V AC |
Mechanically held 3-wire 277V AC |
| Control Code | E | M212 | M224 | M2120 | M2277 | M312 | M324 | M3120 | M3277 |