Product Selection

Build a Catalog Number


Top Wiring for Non-Motor and Lighting Loads

Maximum Continuous
Ampere Ratings [A]
Open Type
Without Enclosure
Tungsten Lamp Loads
(Max. 480V Line, 277V Load)
General Use Click to enlarge - 500-1_22-1
Resistive Heating
Ballast Lighting
(Fluorescent)
Discharge Lighting
(Mercury Vapor High Pressure Sodium and Metal Halide)
Cat. No.
2 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
5 10 500L-TOÄ92
15 20 500L-AOÄ92
30 30 500L-BOÄ92
60 60 500L-COÄ92
100 100 500L-DOÄ92
200 200 500L-EOÄ92
300 300 500L-FOÄ92
540 540
810‡  810 500L-HOÄ92
1215‡  1215 500L-JOÄ92
2250‡  2250 500L-KOÄ92
  

‡ Does not include line and load lugs, see for kits.
∆ Only available on sizes 00…5. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA values on AC Coil Data.
♣ This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
◆ This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
♠ This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
∇ This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.


Maximum Continuous
Ampere Ratings [A]
Open Type
Without Enclosure
Type 1
General Purpose
Enclosure
Type 4/4X
Watertight, Corrosion-
Resistant Enclosure
Stainless Steel
Type 3R/4/12
Rainproof, Dusttight
Industrial Use Enclosure
Tungsten Lamp Loads
(Max. 480V Line, 277V Load)
General Use Click to enlarge - 500-1_22-5a
Resistive Heating
Ballast Lighting
(Fluorescent)
Discharge Lighting
(Mercury Vapor High Pressure
Sodium and Metal Halide)
3 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
Cat. No. Cat. No. Cat. No.★  Cat. No.
5 10 500L-TOÄ930 500L-TAÄ930
15 20 500L-AOÄ930 500L-AAÄ930 500L-ACÄ930 500L-AJÄ930
30 30 500L-BOÄ930 500L-BAÄ930 500L-BCÄ930 500L-BJÄ930
60 60 500L-COÄ930 500L-CAÄ930 500L-CCÄ930 500L-CJÄ930
100 100 500L-DOÄ930 500L-DAÄ930 500L-DCÄ930 500L-DJÄ930
200 200 500L-EOÄ930 500L-EAÄ930 500L-ECÄ930 500L-EJÄ930
300 300 500L-FOÄ930 500L-FAÄ930 500L-FCÄ930 500L-FJÄ930
540‡ §  540 500L-GOÄ930 500L-GAÄ930 500L-GCÄ930 500L-GJÄ930
810‡  810 500L-HOÄ930 500L-HAÄ930 500L-HCÄ930 500L-HJÄ930
1215‡  1215 500L-JOÄ930 500L-JAÄ930
2250‡  2250 500L-KOÄ930 500L-KAÄ930
Tungsten Lamp Loads
(Max. 480V Line, 277V Load)

General Use Click to enlarge - 500-1_23-2_nofootnote
Resistive Heating
Ballast Lighting
(Fluorescent)
Discharge Lighting
(Mercury Vapor High Pressure
Sodium and Metal Halide)
Cat. No. Cat. No. Cat. No.★  Cat. No.
4 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
5 10 500L-TOÄ94 500L-TAÄ940
15 20 500L-AOÄ94 500L-AAÄ940 500L-ACÄ940 500L-AJÄ940
30 30 500L-BOÄ94 500L-BAÄ940 500L-BCÄ940 500L-BJÄ940
60 60 500L-COÄ94 500L-CAÄ940 500L-CCÄ940 500L-CJÄ940
100 100 500L-DOÄ94 500L-DAÄ940 500L-DCÄ940 500L-DJÄ940
200 200 500L-EOÄ94 500L-EAÄ940 500L-ECÄ940 500L-EJÄ940
300 300 500L-FOÄ94 500L-FAÄ940 500L-FCÄ940 500L-FJÄ940
  

Maximum Continuous
Ampere Ratings [A]
Open Type
Without Enclosure
Type 1
General Purpose
Enclosure
Type 4/4X
Watertight, Corrosion-
Resistant Enclosure
Stainless Steel
Type 3R/4/12
Rainproof, Dusttight
Industrial Use Enclosure
  

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 500L-AOÄ94 becomes Cat. No. 500L-AOD94. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


  [V] 24∆  110-
115
115-
120
200-
208
220-
230
230-
240
240 277 380 380-
400
415 440-
460
460-
480
500 550 575-
600
AC, 50 Hz K S♣  P♠  T N KN I Q M R
AC, 60 Hz J D◆  H A∇  F U B C
  

Special Purpose Bolted Enclosures — Hazardous Location

Contactor Type 7 & 9; Class I, Groups C & D; Class II, Groups E, F & G
– Divisions 1 & 2 – Enclosure Code (E)
Type 3R, 7 & 9; Class I, Groups C & D; Class II, Groups E, F & G
– Divisions 1 & 2 – Enclosure Code (H)
Size Poles
0 3 Available Available
1
2
3
4
5
  

★ Fiberglass-reinforced polyester hubs are included with each starter.
‡ Does not include line and load lugs, see for kits.
§ Feed-through wiring only.
∆ Only available on sizes 00…5. When using 24V coils on size 4 or 5, an interposing relay may be required. See coil VA values on AC Coil Data.
♣ This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
◆ This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
♠ This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
∇ This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.