Feeder Disconnect Lighting Contactors

Catalogs > Industrial Controls Catalog > Lighting Control > Feeder Disconnect Lighting Contactors > Bulletin 500FL Feed-Through Wiring Contactors For Non-Motor and Lighting Loads

Bulletin 500FL Feed-Through Wiring Contactors For Non-Motor and Lighting Loads

Introduction Standards Compliance and Certifications Catalog Number Explanation Product Selection Modifications for Non-Combination Devices
Accessories Specifications Full Load Motor Currents Approximate Dimensions Renewal Parts
Your order must include 1) Cat. No. of contactor selected, 2) modifications, if any, and 3) for motor loads, use Bulletin 500F contactors listed on Bulletin 500F.

Product Selection

Build a Catalog Number


Feed-Through Wiring for Non-Motor and Lighting Loads

2 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz 3 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
Maximum Continuous
Ampere Ratings [A]
Open Type
without Enclosure
Maximum Continuous
Ampere Ratings [A]
Open Type
without Enclosure
Tungsten Lamp Loads
(Maximum
480V Line
277V Load)
Non-Motor Loads
General Use
Click to enlarge - 500-1_22-1 Tungsten Lamp Loads
(Maximum
480V Line
277V Load)
Non-Motor Loads
General Use
Click to enlarge - 500-1_22-4
Resistive Heating Resistive Heating
Ballast Lighting
(Fluorescent)
Ballast Lighting
(Fluorescent)
Discharge Lighting
(Mercury Vapor High Pressure Sodium, and Metal Halide)
Cat. No. Discharge Lighting
(Mercury Vapor High Pressure Sodium, and Metal Halide)
Cat. No.
15 20 500FL-AOÄ92 15 20 500FL-AOÄ93
30 30 500FL-BOÄ92 30 30 500FL-BOÄ93
60 60 500FL-COÄ92 60 60 500FL-COÄ93
100 100 500FL-DOÄ92 100 100 500FL-DOÄ93
200 200 500FL-EOÄ92 200 200 500FL-EOÄ93
300 300 500FL-FOÄ92 300 300 500FL-FOÄ93
  

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 500FL-AOÄ92 becomes Cat. No. 500FL-AOD92. For other voltages, consult your local Rockwell Automatino sales office or Allen‑Bradley distributor.


  [V] 24 110-
115
115-
120
200-
208
220-
230
230-
240
240 277 380 380-
400
415 440-
460
460-
480
500 550 575-
600
AC, 50 Hz K S¬  P‡  T N KN I Q M R
AC, 60 Hz J DT  H A§  F U B C
  
¬ This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
T This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
‡ This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
§ This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.