Bulletin 500LP Top Wiring Permanent Magnet Latching Contactors For Non-Motor and Lighting Loads

Product Overview


Click to enlarge - 500LP-1_30-1
30 A, 3-Pole
Open Type without Enclosure


Bulletin 500LP


Description

Bulletin 500LP open type contactors are permanent magnet latching type contactors designed to switch the current to incandescent filament, fluorescent, mercury arc lamps, capacitors, and other non-motor loads.

Feeder disconnect type lighting contactors are used for turning large blocks of lights on and off.


Standards Compliance and Certifications

Standards Compliance

NEMA/EEMAC ICS 2
UL 508
CSA C22.2, No. 14


Certifications

UL Listed (File No. E14843; Guide No. NRNT)
CSA Certified (File No. LR1234)


Catalog Number Explanation

For flexibility, devices may be ordered in a convenient modular kit or as individual components.


Modular Kit Example Cat. No.

500 B O D 930 17
      a    b    c    d    e

a
NEMA Size
Code Description
A 0
B 1
C 2
D 3
E 4

b
NEMA Enclosure Type
Code Type
O No enclosure

c
Nominal Coil Voltage
Code Voltage Frequency
A 220V
240V
50 Hz
60 Hz
B 440V
480V
50 Hz
60 Hz
C 550V
600V
50 Hz
60 Hz
D 110V
120V
50 Hz
60 Hz
F 277V 60 Hz
H 200…208V 60 Hz
I 415V 50 Hz
J 24V 50/60 Hz
N 380V 50 Hz
VL 24V DC
VG 125…250V DC

d
Number of Poles
Code Voltage Description
930 Three Power Poles and (1) N.O. Auxiliary Contact
940 Four Power Poles and (1) N.O. Auxiliary Contact
950 Five Power Poles and (1) N.O. Auxiliary Contact

e
Options
Code Description
17 Surge Suppressor for 120 or 240V AC Coil
90 (1) N.O. Auxiliary Contact★ 
91 (1) N.C. Auxiliary Contact★ 

★ Up to (6) combinations of auxiliary contacts can be selected. Example: Code 90011 indicates (2) N.O. and (2) N.C. contacts.


Product Selection

Build a Catalog Number


Your order must include 1) Cat. No. of contactor selected and 2) modifications, if any.

Note: For motor load application, order a Bulletin 500PM. For Bulletin 500PM information, contact your local Rockwell Automation sales office or Allen‑Bradley distributor.

Maximum Continuous
Ampere Ratings [A]
Open Type
Without
Enclosure
Type 1 General
Purpose
Enclosure
Tungsten Lamp Loads
(Maximum 480V Line 277V Load)


General Use Click to enlarge - 500-1_22-1
Resistive Heating
Ballast Lighting
(Fluorescent)
Discharge Lighting
(Mercury Vapor High Pressure Sodium, and Metal Halide)
Cat. No. Cat. No.
2 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
15 20 500LP-AOÄ92
30 30 500LP-BOÄ92
60 60 500LP-COÄ92
100 100 500LP-DOÄ92
200 200 500LP-EOÄ92
300 300 500LP-FOÄ92
3 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
    Click to enlarge - 500-1_22-5a
15 20 500LP-AOÄ93 500LP-AAÄ930
30 30 500LP-BOÄ93 500LP-BAÄ930
60 60 500LP-COÄ93 500LP-CAÄ930
100 100 500LP-DOÄ93 500LP-DAÄ930
200 200 500LP-EOÄ93 500LP-EAÄ930
300 300 500LP-FOÄ93 500LP-FAÄ930
4 Power Poles Ÿ 600V AC Maximum Ÿ 60 Hz
    Click to enlarge - 500-1_23-2_nofootnote
15 20 500LP-AOÄ94 500LP-AAÄ940
30 30 500LP-BOÄ94 500LP-BAÄ940
60 60 500LP-COÄ94 500LP-CAÄ940
100 100 500LP-DOÄ94 500LP-DAÄ940
200 200 500LP-EOÄ94 500LP-EAÄ940
300 300
  

Ä Coil Voltage Code

The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 500LP-AOÄ92 becomes Cat. No. 500LP-AOD92. For other voltages, consult your local Rockwell Automation sales office or Allen‑Bradley distributor.

  [V] 24★  110-
115
115-
120
200-
208
220-
230
230-
240
240 277
AC, 50 Hz K S‡  P♣  T
AC, 60 Hz J D§  H A∆  F
  [V] 380V 380-
400V
415V 440-
460V
460-
480V
500V 550V 575-
600V
AC, 50 Hz N KN I Q M R
AC, 60 Hz U B C
  
★ When using 24V coils on sizes 4 or 5, an interposing relay may be required.
‡ This coil is optimized for 110…115V, 50 Hz applications, but can be used at 120V, 60 Hz nominal.
§ This coil is optimized for 115…120V, 60 Hz applications, but can be used at 110V, 50 Hz nominal.
♣ This coil is optimized for 220…230V, 50 Hz applications, but can be used at 240V, 60 Hz nominal.
∆ This coil is optimized for 230…240V, 60 Hz applications, but can be used at 220V, 50 Hz nominal.

Typical Wiring Diagram

Click to enlarge - 500LP-1_30-5

Modifications for Non-Combination Devices

For Use on Bulletins 500, 500F, 500L, 500LP, 505, 505V, 509, 520, and 520V; excluding Modular Kits

Listed on this and the following pages are factory-installed modifications and special features that are available for the low voltage (600V maximum) contactors/starters listed in this catalog. To order, add a dash followed by the suffix number listed in these tables to the end of the product cat. no. Example: Cat. No. 509-BAD-A2E-1.

Bulletin 500 Size Rating 0 1 2 3 4 5 6 7 8 9
Bulletin 500L Ampere Rating 15/20 30 60 100 200 300 540 810 1215 2250
  

Description of Modification Suffix
No.
Enclosure
Type
NEMA Size
00 0 1 2 3 4 5 6 7 8 9
Pilot Devices in Cover or Flange
Full Voltage Non-Reversing Single Speed Contactors or Starters (Buls. 500, 500F, 500L, 500LP, 509)
                     
    START-STOP Push Button
    I/O (Canada only)
1
1
1
1
1★ 
3R/4/12, 4/4X
Bolted‡ 
Unilock§ 
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
    ON-OFF Push Button 1E
1E
1E
1E
1★ 
3R/12, 4/4X, 4X
Bolted‡ 
Unilock§ 
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
    HAND-OFF-AUTO Selector Switch 3
3
3
3
1★ 
3R/12, 4/4X, 4X
Bolted‡ 
Unilock§ 
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
A
A
NA
A
A
NA
NA
NA
    OFF-ON Selector Switch 3E
3E
3E
3E
1★ 
3R/12, 4/4X, 4X
Bolted‡ 
Unilock§ 
A
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
A
NA
NA
NA
A
NA
NA
NA
    HAND-OFF-AUTO Selector Switch
    (For Permanent Magnet Latch Type Contactor Only)
3 All Listed★  NA A A A A A A NA NA NA NA
    PILOT LIGHT (Red Lens) 4R
4R
4R
1, 3R/12, 4/4X, 4X★ ♣ 
Bolted‡ 
Unilock§ 
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
A
NA
NA
A
NA
NA
A
NA
NA
    PUSH-TO-TEST PILOT LIGHT
    (Red Lens)
5R
5R
1, 3R/12, 4/4X, 4X
Bolted‡ 
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
Full Voltage Reversing and Multi-Speed Starters
(Buls. 505, 505V, 520V, 520V)
                     
    FOR-REV-STOP Push Button 1
1
1
1, 3R/12, 4/4X, 4X
Bolted‡ 
Unilock§ 
A
NA
NA
A
A
NA
A
A
NA
A
A
NA
A
A
NA
A
A
NA
A
A
NA
A
A
NA
A
NA
NA
A
NA
NA
A
NA
NA
    FOR-OFF-REV Selector Switch 3
3
3
1, 3R/12, 4/4X, 4X
Bolted‡ 
Unilock§ 
A
NA
NA
A
A
A
A
A
A
A
A
NA
A
A
NA
A
A
NA
A
A
NA
A
NA
NA
A
NA
NA
A
NA
NA
A
NA
NA
    HIGH-LOW-STOP Push Button 1
1
1, 3R/12, 4/4X, 4X
Bolted‡ 
A
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
NA
A
NA
A
NA
    HIGH-OFF-LOW Selector Switch 3
3
1, 3R/12, 4/4X, 4X
Bolted‡ 
A
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
NA
A
NA
A
NA
    HIGH-LOW-OFF-AUTO Selector Switch 3J 1, 3R/12, 4/4X, 4X NA A A A A A A A A A A
    PILOT LIGHTS (2) 4R 1, 3R/12, 4/4X, 4X∆  NA A A A A A A A A A A
  
A = Available
NA = Not Available
★ Bulletin 500L and 500FL require a normally open auxiliary contact when used with a push button. See Contactor Accessories . Only one push button or one selector switch (not both) may be added to a Bulletin 509 for NEMA Type 1 without transformers. Only one pilot light may be added to a Bulletin 509 Type 1 without transformers.
‡ Bolted suitable for Type 7 & 9 or Type 3R, 7 & 9.
§ Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9 with the addition of a drain or breather and drain.
♣ OFF pilot lights for non-reversing and non-multi-speed applications require a normally closed auxiliary contact add -91 to Cat. No. Red and amber (up to
240V AC) are the only colors available on Type 1 non-combination starters (lift-off). On non-combination starters (hinged), specify other lens colors by changing the letter to: A = Amber; B = Blue; C = Clear; G = Green; W = White.
∆ For multi-speed and reversing starters, one pilot light for each contactor. Add additional letters to identify two lens colors. The first letter specifies FORWARD, HIGH, or ON; the second letter specifies REVERSE, LOW, or OFF; e.g., 4AG.
    

For Use on Bulletins 500, 500F, 500L, 500LP, 505, 505V, 509, 520, and 520V; excluding Modular Kits

Description of Modification Suffix
No.
Enclosure
Type
NEMA Size
00 0 1 2 3 4 5 6 7 8 9
Control Circuit Transformer★                       
Includes 2 primary fuses and 1 secondary fuse
    with standard capacity 60 or 50 Hz
6P
6P
6P
1, 3R/12, 4/4X, 4X
Bolted§ 
Unilock♣ 
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
STD
STD
STD
STD
NA
NA
STD
NA
NA
STD
NA
NA
    With 100 W extra capacity 60 or 50 Hz 6XP
6XP
6XP
1, 3R/12, 4/4X, 4X
Bolted§ 
Unilock♣ 
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
STD
STD
STD
STD
NA
NA
STD
NA
NA
STD
NA
NA
Control Circuit
Auxiliary contact installed on contactor
                     
  N.O.
N.C.
90∆ ◆ 
91∆ ◆ 
All listed
All listed
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Fused control circuit for applications less transformer                          
  (1 Fuse — Fuse Included)
(2 Fuses — Fuses Included)
21
22
1, 3R/12, 4/4X, 4X
1, 3R/12, 4/4X, 4X
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
Surge suppression for 120 or 240V AC Coil 17 All listed NA A A A A A A NA NA NA NA
Terminal blocks (Cat. No. 1492-CA1 or similar) per block ♠  1, 3R/12, 4/4X, 4X NA A A A A A A A NA NA NA
DC operation of control circuit (power circuit remains AC)
Add letters “DC” to Bulletin No. (add per solenoid)
♠  Open
1, 4/4X, 4X, 12
NA
NA
A
♠ 
A
♠ 
A
♠ 
A
♠ 
A
♠ 
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Overload Relays (Eutectic Alloy)                      
N.O. alarm contact adder
N.C. alarm contact adder
Omit 3 overload relays
(Bulletin 592)
(Bulletin 592)
(For Bulletins 505 and 520 only)
9
9A
23∇ 
All listed
All listed
All listed
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
Auxiliary Relays (Indicate Contact Arrangement and Coil Voltage)                      
3Æ Powermonitor (Timemark Model 258) 400 1, 3R/12, 4/4X, 4X NA A A A A A A NA NA NA NA
Control relay (4-pole maximum)♠  1, 3R/12
4/4X, 4X
Unilock♣ 
NA
NA
NA
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
NA
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Addition of timing relay♠  1, 3R/12
4/4X, 4X
Unilock♣ 
NA
NA
NA
A
A
NA
A
A
NA
A
A
NA
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Add Bulletin 813S♠  (Line voltage monitor)
(Line current monitor)


NA
NA
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Bulletin 596 (used on Bulletin 500…509, 3-pole maximum)
(Coil - 180 s timing range)
                         
  ON Delay
OFF Delay
87A
87B
Open Type
Open Type
NA
NA
A
A
A
A
A
A
A
A
A
A
A
A
NA
NA
NA
NA
NA
NA
NA
NA
Extra strong coil for addition of power pole adders required for sizes 2…4 88 All listed NA NA NA A A A NA NA NA NA NA
Form A compelling relay♯  (used on Bulletin 520) 70 1, 3R/12, 4/4X, 4X NA A A A A A A A NA NA NA
Form B auto. seq. accelerating relay for each higher speed
-controls the sequence of acceleration from low to high speed. (Used on Bulletin 520)

71

1, 3R/12, 4/4X, 4X

NA

A

A

A

A

A

A

A

NA

NA

NA
Form C auto. seq. decelerating relay for each lower speed
-interposes a time delay between each lower speed. (Used on Bulletin 520)

72

1, 3R/12, 4/4X, 4X

NA

A

A

A

A

A

A

A

NA

NA

NA
Enclosure                      
Breather 136 Bolted§  NA A A A A A A NA NA NA NA
Breather and drain 137 Unilock♣                       
and Bolted§  NA A A A A A A NA NA NA NA
Drain 138 Unilock♣                       
and Bolted§  NA A A A A A A NA NA NA NA
Protective Covers for Contactors and Starters 426 1, 3R/12, 4/4X, 4                      
NA A A A A A A NA NA NA NA
  
A = Available
NA = Not Available
STD = Standard
★ If the transformer secondary is to be grounded, add the suffix letter G at no aditional charge. Example: 6GP.
§ Bolted suitable for Type 7 & 9 or Type 3R, 7 & 9.
♣ Unilock suitable for Type 7 & 9 or Type 3R, 7 & 9.
∆ Multiple auxiliary contacts are to be group coded: e.g. use 9 followed by second digit for each auxiliary used: 90-91-98 group coded to “9018”. Maximum quantity of auxuliary contacts (any type) group coded shall be 5.
◆ For Bulletins 505 and 520 devices, one auxiliary contact is installed on each of the two contactors.
♠ Order by description.
∇ Contactors provided on short mounting plate, please contact your local Rockwell Automation sales office or Allen-Bradley distributor for dimensions.
& Only one relay per starter.
♯ Through control wiring the starter is forced to operate in the low speed before switching to high speed.

Accessories

Contactor Accessories

   Click to enlarge - 500DC_DCController_4c
Bulletin 500DC — Electronic DC Coil Controller
Features
  • Compact size – NEMA sizes 0…3

  • Versatility – Fully assembled unit or as a retro-fit kit

  • LED status indication – LED diagnostics determine if the controller is functioning correctly

  • Low power consumption – Draws 3.5 watts steady state

  • Built-in thermal protection – The controller is protected from over temperature

  • Reverse polarity protection – Should the wiring be reversed during installation or coil change, no damage will occur
  • NEMA Size 0…1, 2, and 3
    DC Voltage
  • 24V
  • 125…250V
  • Min. DC Inrush Switching Requirement for Logic Control Device
  • 6.7 A

  • 8.2 A

  • 16.5 A
  • 4.9 A

  • 7.0 A

  • 14.3 A
  • Certifications
  • cULus Listed (File No. E14840, Guide No. NKCR, NKCR7)

  • CE mark (per EN 60947-5-1)
  • Example Cat. No. An example of a factory-assembled contactor catalog number is Cat. No. 500DC-BOVL930. For further details visit the on-line catalog.
    For Use With Bulletin 509 (See Bulletin 509 Open Type Full Voltage Starter ).
    For Bulletins 505 and 520, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
      

    For use on Bulletins 500, 500F, 500L, 500FL, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1233X, and 1233V

    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_105-2 Coils (60 Hz)            
    115…120V
    0…1 CB-236
    200…208V CB-249
    230…240V CB-254
    460…480V CB-273
    575…600V CB-278
    115…120V 2 CC-236
    200…208V CC-249
    230…240V CC-254
    460…480V CC-273
    575…600V CC-278
    115…120V 3 CD-236
    200…208V CD-249
    230…240V CD-254
    460…480V CD-273
    575…600V CD-278
    115…120V 4 CE-236
    200…208V CE-249
    230…240V CE-254
    460…480V CE-273
    575…600V CE-278
    115…120V 5
    (SER. L)
    AF-236
    200…208V AF-249
    230…240V AF-254
    Note: For complete listing of coils available, see Bulletin 500 Line of Contactors and Starters (excluding Modular Kits) 460…480V AF-273
    575…600V 5 AF-278
    Surge Suppressor — Made to be easily mounted directly across the coil terminals of contactors and starters with 120V or 240V AC coils. The purpose of the suppressor is to limit voltage transients for applications requiring interface with solid-state components. One suppressor is required per coil.
      RC Module            
    AC Operating
    Mechanism
    24…48V AC, 50/60 Hz
    00★  100-FSC48
    110…280V AC, 50/60 Hz 100-FSC280
    380…480V AC, 50/60 Hz 100-FSC480
    Click to enlarge - 500Line-1_105-5 Varistor Module            
    AC/DC Operating
    Mechanism
    12…55V AC/ 12…77V DC
    00★  100-FSV55
    Cat. No. 100-FSC280 56…136V AC/ 78…180V DC 100-FSV136
      137…277V AC/ 181…350V DC 100-FSV277
    278…575V AC 100-FSV575
    Click to enlarge - 500Line-1_105-6 12…120V AC 0…5 599-K04
    240…264V AC Varistor 599-KA04
    12…120V AC 6 199-FSMA1‡ 
    12…120V AC
    Varistor
    199-GSMA1§ 
    Cat. No. 599-K04 120V AC 7…8 700-N24
      
    ★ For non-combination starters only.
    ‡ For use on the interposing relay.
    § For use on the contactor or starter.

    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_105-1 Terminal and Lug Covers        

    Line side terminal covers
    0…1 599-TC01N
    2 599-TC2N
    3 599-TC3N
    4 599-TC4N
    5 599-TC5N
    Line side terminal covers (reversing) 0…1 599-TC01R
    Click to enlarge - 500Line-1_105-4 Tie Point Terminal 0…2 599-TP02
    3…5 599-TP34
      

    Description For Use With No. of Poles NEMA Size Cat. No.
    Protective Covers 500/F/FL, 500L, 500LP, 505 3 0…1 599-PC01
    Click to enlarge - 1_92 509, 505, 520E (2), 520F/G 3 0…1 599-PS01◆ 
    500L, 500LP 5 0…1 599-PC01-5♠ 
    520F/G 5 0…1 599-PS01-5◆ 
    500/F/FL, 500L, 500LP, 505 3 2 599-PC2
    509, 505, 520E (2), 520F/G 3 2 599-PS2◆ 
    500L, 500LP 5 2 599-PC2-5♠ 
    520F/G 5 2 599-PS2-5◆ 
    500/F/FL, 500L, 500LP, 505 3 3 599-PC3
    509, 505, 520E (2), 520F/G 3 3 599-PS3◆ 
    500L, 500LP 5 3 599-PC3-5♠ 
    520F/G 5 3 599-PS3-5◆ 
    500/F/FL, 500L, 500LP, 505 3 4 599-PC4
    509, 505, 520E (2), 520F/G 3 4 599-PS4◆ 
    500L, 500LP 5 4 599-PC4-5♠ 
    520F/G 5 4 599-PS4-5◆ 
    500/F/FL, 500L, 500LP 3 5 599-PC5
    Cat. No. 599‑PS01 509 3 5 599-PS5◆ 
      
    ♠ Used on 5-pole contactors and starters.
    ◆ Bul. 592 Eutectic alloy or solid-state overload relays.

    Timer Attachment Kit — A pneumatic timer attachment may be field installed in the space of two adjacent auxiliary contact blocks. Timing units are available for either ON-Delay or OFF-Delay operation with a timed set of one (1) N.O. and one (1) N.C. snap-action contacts that are electrically isolated.
    Repetitive accuracy within the timer range is approximately ±10% provided a minimum reset time of 75 ms is allowed.
    Note:
  • Sizes 0…5: Timers can be added to the left- or right-hand side of the contactor body. On Size 00 they can be mounted to the front of the contactor.

  • Size 0, 1 and 2: Timers cannot be used on the same side as power pole adders.

  • Size 2 Devices: The operating coil must be changed. See Bulletin 500 Line of Contactors and Starters (excluding Modular Kits) and refer to the size 2 operating coil listing. Order the coil listed for a 4‑…5‑pole device.

  • Note: These coils can also be factory installed.
  • Enclosed Devices: Please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

  • Contact Ratings:  NEMA A600 (10 A, 600V AC max.)
    NEMA P300 (5 A, 300V DC max.)
    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_105-7 On-Delay 00♣  100-FPTA30
    On-Delay 100-FPTA180
    Off-Delay 100-FPTB30
    Off-Delay 100-FPTB180
    Left-hand ON Delay 0…5 596-TL32
    Left-hand OFF Delay 596-TL33
    Right-hand ON Delay 596-TR32
    Cat No. 596-TR32 Right-hand OFF Delay 596-TR33
      
    ♣ For open type, non-combination starters only.

    Description NEMA Size Cat. No.
    Auxiliary Contact — Contactors 1 N.O. 0…5 595-A
    Click to enlarge - 500Line-1_106-1 2 N.O. 0…5 595-AA
    1 N.C. 0…5 595-B
    2 N.C. 0…5 595-BB
    1 N.O. and N.C. 0…5 595-AB
    1 N.C.L.B. 0…5 595-BL
    1 N.O. 6 195-GA10
    1 N.O. 7 ∆  1495-J6
    2 N.O. 6 195-GA20
    2 N.O. 7…8 ∆  1495-K6
    2 N.O. 9 ∆  1495-K8
    1 N.C. 6 195-GB01
    1 N.C. 7…9 ∆  1495-J6
    2 N.C. 6 195-GB02
    2 N.C. 7…8 ∆  1495-K6
    2 N.C. 9 ∆  1495-K8
    1 N.O. and N.C. 6 195-GB11
    2 N.O. 7…8 ∆  1495-K6
    2 N.O. 9 ∆  1495-K8
    1 N.C.L.B. 6 195-GL01
      
    ∆ The normally open contacts can easily be changed to normally closed in the field.

    Power Pole Adders — The 1 N.O. and 1 N.C. power poles may be field added to all size 0…4 Bulletin 500 line contactors and starters except the Bulletin 500L and 500FL. Two- and three-pole contactors will accept a maximum of two adder poles and four-pole devices will accept one adder pole. Each adder pole kit includes a mechanical load balancer to be used when only one power pole is added.
    Note: When power poles are added to Size 2, 3, or 4 (2- or 3-pole devices) the operating coil must be changed. Refer to the listing for the size of your contactor or starter. Order the operating coil listed for a 4-…5-pole device.
    Note: These coils can also be factory installed.
    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_106-6 1 N.O. 0…1 599-P01A
    1 N.C. 599-P01B
    1 N.C. Late Break 599-P01BL
    1 N.O. 2 599-P2A
    1 N.C. 599-P2B
    1 N.C. Late Break 599-P2BL
    1 N.O. 3 599-P3A
    1 N.C. 599-P3B
    Cat. No. 599-P01A (1 N.O.)
    Size 0…1, 27 Amps.
    1 N.O. 4 599-P4A
    1 N.C. 599-P4B
    Contactor Kick-off Springs — For horizontal mounting of 2- or 3-pole Bulletin 500 contactors and starters.
    Note: When kick-off springs are added to Size 2, 3 or 4, the operating coil must be changed. Refer to the listing for the size of your contactor or starter. Order the operating coil listed for a 4-pole device.
    Note: These coils can also be factory installed.
    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_106-8 0…1 599-N11
    2 599-N12
    3 599-N13
    4…5 599-N14
      

      Wire Size NEMA Size Cat. No.
    Click to enlarge - 1_93 Lug Connectors (3 per package)
    #14…8 AWG Wire 0…1 ★ 
    #14…4 AWG Wire 2 1494R-N1
    #8…1/0 AWG Wire 3 1494R-N2
    #6…4/0 AWG Wire 4 1494R-N3
    Cat. No. 1494R-N3 2 of #1/0…350 MCM Wire 5 42450-804-01
      
    ★ All terminals of the 30 A switches are furnished with self-lifting pressure plate connectors as standard.

    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_107-1 Terminal Lug Kit Two #1/0 150…500 MCM
    1 required per terminal
    6 199-LJ1
    Terminal Lug Kit #4 AWG…500 MCM
    3 required per terminal for Size 7 and 4 required per terminal for Size 8
    7…8 199-LG1
      

    Description NEMA Size Cat. No.
    Auxiliary Contact Adder Decks — The same 2- and 4-pole auxiliary contact blocks in various combinations of normally open and normally closed will slide and snap on to the front of the contactor. Adder decks have convenient backed out wire clamps to make lugging of control wires unnecessary. Fits on Open Type devices only.
    Click to enlarge - 500Line-1_106-2 2 N.O. 00 100-FA20
    1 N.O. -1 N.C. 100-FA11
    2 N.C. 100-FA02
    4 N.O. 100-FA40
    3 N.O.-1 N.C. 100-FA31
    2 N.O. -2 N.C. 100-FA22
    4-pole 4 N.C. 100-FA04
    24V DC Interface Module — Mounts to the top of the contactor. It provides a 24V DC, 0.5 w input signal that can be used to operate the 24…240V AC coil of the contactor. Fits on Open Type devices only.
    Click to enlarge - 500Line-1_106-3 00 100-JE
    Latch Attachment — On the front of the contactor. Fits on Open Type devices only.
    Click to enlarge - 500Line-1_106-4 00 100-FL11Ä
    Interposing Contactor — For open type Bulletin 500 and 500L. 120V, 60 Hz 6 500-NX100D
    240V, 60 Hz 6 500-NX100A
    Top Wiring Kit — Consists of (3) power lugs for the purpose of making extra connections to the load side of the contactor. A second set of overload relays can be wired to these lugs if two motors are being controlled by a single contactor.
    Click to enlarge - 500Line-1_106-7 0…1 599-TW01
    2 599-TW2
    3 599-TW3
    4 599-TW4
    Cat No. 599-TW01 5 599-TW5P
      

    Ä Voltage Suffix Code

    The cat. no. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No.
    Example: 120V, 60 Hz: Cat. No. 100-FL11Ä becomes Cat. No. 100-FL11D. For other voltages, please consult your local Rockwell Automation sales office or Allen‑Bradley distributor.


      [V] 24 48 100 110 120 230…
    240
    240 277 380…
    400
    400…
    415
    400 480
    50 Hz K Y KP D VA T N G B
    60 Hz J D A T N B
      
    § To complete cat. no., insert in the third position the desired numeric symbol (0…5) or one of the following letters — A, B, C, D, E, F, H, L, M, P, R, S, T, U, or W.

    Description Enclosure Type NEMA Size Cat. No.
    Click to enlarge - 500Line-1_116-7 Click to enlarge - 500Line-1_116-8 Adapter Plates — For replacement of:
  • Allen-Bradley
  • (Bulletin 709 Series K)
  • Cutler Hammer
  • (Citation & Freedom Series)
  • Furnas (Class 14 and ESP 100)

  • General Electric (Series 300)

  • Joslyn-Clark (Type HP)

  • Square D (Type S)

  • Westinghouse
  • (A200 and W200 Advantage)
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0, 1 599-CP01
    2 599-CP2
      

    For use on Bulletins 512V, 513V, 1232V, 1233V

    Contactors are supplied with one normally open and one normally closed auxiliary contact (A600 rating) as standard. Additional auxiliary contacts, two normally open and two normally closed, can be added in the field.

    Description Cat. No.
    Auxiliary Contact (10 A @ 600V) 1195C-N3
    Auxiliary Contact (10 mA @ 5V DC) 1195C-N4
      

    Overload Accessories

    For use on Bulletins 500, 500F, 500FL, 500L, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1233X, and 1233V

    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_107-2 Auxiliary Contact —
    For eutectic alloy overload relays only★ 
       
    1 N.O. 00, 3-phase‡  595-A00
    1 N.C. 00, 3-phase‡  595-B00
    1 N.O. 0…2, 5…9 595-A02
    Auxillary Contact —
    For eutectic alloy overload relays only★ 
    Contact Ratings —
    NEMA A600 (10 A, 600V AC max.)
    NEMA P300 (5 A, 300V DC max.)
    1 N.C. 595-B02
    1 N.O. 3…4 595-A34§ 
    1 N.C. 595-B34♣ 
      

    Description Max. Continuous Current Rating [A] Cat. No.
    Click to enlarge - 500Line-1_116-6 DIN Rail Mounting Adapter for Bulletin 592 compact type 3-pole overload relays 40 599-MP1
    DIN Rail Mounting Adapter for Bulletin 592 compact type 1-pole overload relays 62 599-MP2
      

    ★ Auxiliary contact for solid-state overload relays is included in the product.
    ‡ Non-combination starters only.
    § Auxiliary contact mounted on right-hand side of overload relay provides N.O. contact function. Auxiliary contact mounted on left-hand side of overload relay provides N.C. contact function.
    ♣ To be mounted on right-hand side of overload to provide additional AC contact function.


    Voltage Control Accessories

    For use on Bulletins 500, 500F, 500L, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1233X, and 1233V; excluding Modular Kits

    Control Circuit Transformer with Top-Mounted Fuse Block Kits (pre-wired)★ ‡ 

      NEMA Size Primary Voltage Capacity – 120V Secondary Voltage
    Standard 100 W Extra 200 W Extra 300 W Extra 400 W Extra
    VA Cat. No. VA Cat. No. VA Cat. No. VA Cat. No. VA Cat. No.
    Click to enlarge - 1_093 0…2 208V 80 1497-N1PK 130 1497-N15PK 250 1497-N7PK 350 1497-N10PK 500 1497-N18PK
    240V & 480V 1497-N2PK 1497-N16PK 1497-N8PK 1497-N11PK 1497-N19PK
    600V 1497-N3PK 1497-N17PK 1497-N9PK 1497-N12PK 1497-N20PK
    3 208V 200 1497-N4PK 250 1497-N7PK 350 1497-N10PK 500 1497-N18PK 500 1497-N18PK
    240V & 480V 1497-N5PK 1497-N8PK 1497-N11PK 1497-N19PK 1497-N19PK
    600V 1497-N6PK 1497-N9PK 1497-N12PK 1497-N20PK 1497-N20PK
    4 208V 250 1497-N7PK 350 1497-N10PK 500 1497-N18PK
    240V & 480V 1497-N8PK 1497-N11PK 1497-N19PK
    600V 1497-N9PK 1497-N12PK 1497-N20PK
    5 208V 350 1497-N10PK 500 1497-N18PK
    240V & 480V 1497-N11PK 1497-N19PK
    600V 1497-N12PK 1497-N20PK
    6 208V 500 1497-N18PK
    240V & 480V 1497-N19PK
    600V 1497-N20PK
      
    ★ Transformers for NEMA sizes 7…9 are included as standard.
    ‡ Type 4/4X non-metallic enclosures and Type 7 & 9 hazardous location enclosures require transformers with separately mounted fuse blocks. For a complete listing of transformers, see Control Transformers.

    Control Circuit Transformers with Top Mounted Fuse Blocks§ ‡ 

      NEMA Size Primary Voltage/
    3 Pole Fuse Block
    Capacity – 120V Secondary Voltage
    Standard
    VA Cat. No.
    Click to enlarge - 1_093_2 0…2 208V 80 1497-B-HXDX-3-N
    240V & 480V 1497-B-BASX-3-N
    600V 1497-B-CXSX-3-N
    3 208V 200 1497-D-HXDX-3-N
    240V & 480V 1497-D-BASX-3-N
    600V 1497-D-CXSX-3-N
    4 208V 250 1497-E-HXDX-3-N
    240V & 480V 1497-E-BASX-3-N
    600V 1497-E-CXSX-3-N
    5 208V 350 1497-F-HXDX-3-N
    240V & 480V 1497-F-BASX-3-N
    600V 1497-F-CXSX-3-N
      
    § Transformers can be installed in Type 1, 3R, 3R/4/12 painted enclosures and Type 4/4X stainless steel enclosures.
    ‡ Type 4/4X non-metallic enclosures and Type 7 & 9 hazardous location enclosures require transformers with separately mounted fuse blocks. For a complete listing of transformers, see Control Transformers.

    For use on Bulletins 500, 500F, 500L, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1232X, and 1233V; excluding Modular Kits

    For Use When Fuse Block Is Not Integrated with the Transformers

    Click to enlarge - 500Line-1_108-1 Click to enlarge - 500Line-1_108-2 Click to enlarge - 500Line-1_108-3
    Cat. No. 1491-R165
    1-Pole Fuse Block
    Cat. No. 1491-R167
    2-Pole Fuse Block
    Cat. No. 1491-R171
    3-Pole Fuse Block
    Click to enlarge - 500Line-1_108-4 Click to enlarge - 1497-1_235-5  
    Cat. No. 1491-R169
    3-Pole Fuse Block
    Cat. No. 1491-R150
    Fuse Cover without Fuse∆ 
     

    These control circuit fusing kits are intended to be used for control circuit transformer protection and protection of control circuits capable of delivering no more than 200 000 RMS symmetrical amperes, 600V maximum. (Fuses not included.)

    Description★  Cat. No.
    One-pole kit — panel-mounted (midget fuse)‡  1491-R165
    Control Circuit Fuse Block
    For Class CC rejection type fuses (fuses not included)‡ 
    1491-R162
    Two-pole kit — panel-mounted (two midget fuses)‡  1491-R167
    Three-pole kit — panel-mounted (one midget fuse/two Class CC fuses)‡  1491-R169
    Three-pole kit — panel-mounted (three Class CC fuses) 1491-R171
    Single-pole kit — Bulletin 500 line controller mounted (Class CC fuses)§  599-FR04
    One-pole kit — panel-mounted (31…60 A Class J fuse) 1491-R173
    One-pole kit — panel-mounted (61…100 A Class J fuse) 1491-R175
      
    ★ For control circuit transformers with a 350 VA or larger rating, it is recommended that Bussmann Type FNQ-R, Ferraz-Shawmut Type ATDR, Littelfuse Type KLDR time delay fuses, or equivalent be used for primary fusing.
    ‡ These kits use only Class CC or midget fuses (rated 0.5…30 A) such as those offered by the following manufacturers:
    •  Bussmann KTK-R
    •  Ferraz-Shawmut ATM R
    •  Littelfuse KLK
    § Cat. No. 599-FR04 is rated for 6 A fuse maximum. Controller mounting applies to size 0…5 devices only.
    ∆ One cover per pole is required. Example: transformer with top-mounted fuse block requires three covers. Fuse block kit for separate control requires two covers. Fuses not included.

    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_108-6 Single-pole kit — Bulletin 500 line controller mounted (Class CC fuses) 0…5 599-FR04
      
    Note:One cover per pole is required. Example: transformer with top-mounted fuse block requires three covers. Fuse block kit for separate control requires two covers.

    Disconnect Switch Accessories

    For use on Bulletins 502, 502L, 506, 506X, 512, 512H, 512M, 512V, 522, 532, 542, 572, 1242, 1272, 1282, 1232X, and 1232V

      Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_109-1 Fuse Clips    
    0…30 A, 250V AC, Class H 0…2 1401-N41
    0…30 A, 250V AC, Class J
    0…30 A, 600V AC, Class H
    0…30 A, 600V AC, Class J
    31…60 A, 250V AC, Class H
    1…3 1401-N42
    31…60 A, 250V AC, Class J
    31…60 A, 600V AC, Class H
    31…60 A, 600V AC, Class J
    1…3 1401-N43
    61…100 A, 250V AC, Class H
    61…100 A, 250V AC, Class J
    61…100 A, 600V AC, Class H
    61…100 A, 600V AC, Class J
    2…4 1401-N44
    101…200 A, 250V AC, Class H
    101…200 A, 250V AC, Class J
    101…200 A, 600V AC, Class H
    101…200 A, 600V AC, Class J
    3…5 1401-N45
    201…400 A, 250V AC, Class H
    201…400 A, 250V AC, Class J
    201…400 A, 600V AC, Class H
    201…400 A, 600V AC, Class J
    4…5 1401-N46
    0…30 A, 250V AC, Class R
    0…30 A, 600V AC, Class R
    31…60 A, 250V AC, Class R
    0…2‡  1401-N50
    1401-N51
    31…60 A, 600V AC, Class R 1…3 1401-N52
    61…100 A, 250V AC, Class R
    61…100 A, 600V AC, Class R
    2…4 1401-N53
    101…200 A, 250V AC, Class R
    101…200 A, 600V AC, Class R
    3…5 1401-N54
    201…400 A, 250V AC, Class R
    201…400 A, 600V AC, Class R
    5…6 1401-N55
    0…30 A, 250V AC HRC Form II Fusing★ 
    0…30 A, 600V AC HRC Form II Fusing★ 
    31…60 A, 250V AC HRC Form II Fusing★ 
    31…60 A, 600V AC HRC Form II Fusing★ 
    0…2‡ 
    1…3
    ♠ 
    Click to enlarge - 500Line-1_109-2 Auxiliary Contacts for Disconnect Switches
    1 N.O.
    0…5 1495-N8
    1 N.C. 0…5 1495-N9
      
    ★ HRC Form II fusing for Canada only.
    ‡ For 0…30 A only.
    ♠ Fuse clip not required. Fuse bolts directly to switch and trailer fuse block.

    Click to enlarge - 1494-2_19-1 Description For Use With Cat. No.
    Lug Connectors (3 per package) 1494C, 1494F, 1494G, and 1494V Disconnect Switches  
    Disconnect Size [A] Wire Size
    30 #14…8 AWG Wire ★ 
    60 #14…4 AWG Wire ♣  1494R-N1
    100 #8…1/0 AWG Wire ♣  1494R-N2
    200 #6…4/0 AWG Wire ♣  1494R-N3
    400 #6…250 MCM AWG
    16 mm2…120 mm2
    1494R-N14
    400 #4 AWG…500 MCM Wire (oversized) 1494R-N15
    600 (2) of #1/0…350 MCM Wire ♣  1494R-N10
    Cat. No. 1494R-N3 600 (2) of #1/0…350 MCM Wire 1491-N621 or 1491-R621 600 A fuse blocks ∆  1494R-N11
    Click to enlarge - 1495_FuseCover_GS Protective Fuse Covers
    Switch Rating [A] Fuse Class Fuse Clip Rating [A] Cat. No.
    250V 600V
    30
    30
    60
    30
    60
    60
    100
    Non-fusible
    H, R
    H, R
    J
    J
    Non-fusible
    Non-fusible

    30
    60
    30
    60




    30
    60

    1495-N64
    30
    60
    100
    H, R
    H, R
    J


    100
    30
    60
    100
    1495-N65
    100 H, R
    J
    100
    200
    100
    200
    1495-N66
    200
    200
    Non-fusible
    H, J, R
    J


    200
    400


    200
    400
    ◆  1495-N67
    200
    200
    Non-fusible
    H, J, R

    200

    200
    ♠  1495-N62
    400
    400
    Non-fusible
    H, J, R

    400

    400
    ◆  1495-N68
    400
    400
    Non-fusible
    H, J, R

    400

    400
    ♠  1495-N63
    600 Non-fusible
    J

    600

    600
    ◆  1495-N61
      
    ★ All terminals of the 30 A switches are furnished with self-lifting pressure plate connectors (N56, N57, and N58) as standard.
    ♣ Each kit contains three lugs.
    ∆ Each kits contains two lugs.
    ◆ Switch with right-hand mechanism.
    ♠ Switch with left-hand mechanism.

    Circuit Breaker Accessories

    For use on Bulletins 503, 503L, 507, 507X, 513, 513H, 513M, 513V, 523, 533, 543, 573, 1243, 1273, 1283, 1233X, and 1233V

    Description NEMA Size Cat. No.
    Click to enlarge - 500Line-1_110-1 Circuit Breaker Kits    
    3 A, 0…1/3 Hp @ 200 and 230V
    3 A, 0…1 Hp @ 460 and 575V
    0…1 1401-N60
    7 A, 0.5…1 Hp @ 200 and 230V
    7 A, 1.5…3 Hp @ 460 and 575V
    0…1 1401-N61
    15 A, 1.5…3 Hp @ 200 and 230V
    15 A, 5…7.5 Hp @ 460 and 575V
    0…1 1401-N62
    30 A, 5 Hp @ 200V
    30 A, 5…7.5 Hp @ 230V
    30 A, 10…15 Hp @ 460 and 575V
    1…2 1401-N63
    50 A, 5…10 Hp @ 200V
    50 A, 10 Hp @ 230V
    50 A, 20…25 Hp @ 460V
    50 A, 20…30 Hp @ 575V
    1…3 1401-N64
    100 A, 15…25 Hp @ 200 and 230V
    100 A, 30…50 Hp @ 460V
    100 A, 40…50 Hp @ 575V
    2…4 1401-N65
    150 A, 30 Hp @ 200V
    150 A, 30…40 Hp @ 230V
    150 A, 60…75 Hp @ 460V
    150 A, 75…100 Hp @ 575 V
    3…4 1401-N66
    250 A, 125 Hp @ 575V 5 1401-N68
    250 A, 50…60 Hp @ 200V
    250 A, 60…75 Hp @ 230V
    1401-N69
    Click to enlarge - 500Line-1_109-2 Auxiliary Contacts for Disconnect Switches   1495-N8
    One normally open (1 N.O.)
    Adapter kit may be required. ★ 
    Bolted — One normally open (1 N.O.)‡ 
    Unilock — One normally open (1 N.O.)‡ 
    0…5§ 
    4…5♣ 
    One normally closed (1 N.C.)
    Adapter kit may be required.★ 
    Bolted — One normally closed (1 N.C.)‡ 
    Unilock — One normally closed (1 N.C.)‡ 
    0…5 1495-N9
    Click to enlarge - 500Line-1_110-3 Unilock — One normally open (1 N.O.)‡  0…2 1495-N14
    Unilock — One normally closed (1 N.C.)‡  0…2 1495-N15
    HMCP Circuit Breaker Adapter Kits (for mounting 1 or 2 auxiliary contacts)
    400 A Frame‡ 
    5 1495-N16
    150 A Frame 3…4 1495-N21
    250 A Frame - Enclosure Type 1, 3R/4/12, 3R and 4/4X (stainless steel)
    250 A Frame - Enclosure Type 7 & 9 (bolted & Unilock) and 4/4X (non-metallic)
    4…5∆ 
    0…5◆ 
    1495-N22
    250 A Frame - Enclosure Type 1, 3R/4/12, 3R, and 4/4X (stainless steel) 4 1495-N23
    Unilock — 150 A Frame‡  3…4 1495-N21
    Unilock — 250 A Frame‡  4…5 1495-N22
      
    ★ Contact Ratings — NEMA B600 and NEMA P600.
    ‡ Not available on larger sizes 6…9.
    § For Bolted and 1 N.O.
    ♣ For Unilock 1 N.C.
    ∆ For Enclosure Type 1.
    ◆ For Enclosure Types 7 & 9.

    Pilot Device Accessories

    For use on Bulletins 500, 500F, 500L, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1233X, and 1233V

    Description Enclosure Type NEMA Size Cat. No.
    Click to enlarge - 500Line-1_111-1 Selector Switch Kits
    OFF-ON/HAND-OFF-AUTO★ ‡  1 (lift-off) 00…2 599-SSL
    599-SS2L
    HAND-OFF-AUTO 1, 3R/4/12 0…5 599-SS09HJ
    4, 4X (stainless steel and non-metallic) 599-SS09HS
    OFF-ON 1, 3R/4/12 599-SS09OJ
    4, 4X (stainless steel and non-metallic) 599-SS09OS
    FOR-OFF-REV 1, 3R/4/12 599-SS09RJ
    4, 4X (stainless steel and non-metallic) 599-SS09RS
    TEST-OFF-AUTO
    (spring return from TEST)
    1, 3R/4/12 599-SS09TJ
    4, 4X (stainless steel and non-metallic) 599-SS09TS
    FOR-OFF-REV (Unilock) 3R, 7 & 9 0…2 1481-N48
    OFF-ON (Unilock) 1481-N54
    HAND-OFF-AUTO (Unilock) 1481-N55
    OFF-ON (Unilock) 3…5 1481-N59
    HAND-OFF-AUTO (Unilock) 1481-N60
    FOR-OFF-REV (Unilock) 1481-N62
    Click to enlarge - 500Line-1_111-2 Push Button Kits
    START-STOP★ ‡  1 (lift-off) 00…2 599-PBL
    START-STOP 1, 3R/4/12 0…5 599-PB09SJ
    4, 4X (stainless steel and non-metallic) 599-PB09SS
    FOR-REV-STOP 1, 3R/4/12 599-PB09RJ
    4, 4X (stainless steel and non-metallic) 599-PB09RS
    HIGH-LOW-STOP 1, 3R/4/12 599-PB09WJ
    4, 4X (stainless steel and non-metallic) 599-PB09WS
    START-STOP (Unilock) 7 & 9 0…2 1481-N53
    3…5 1481-N58
    START-STOP (bolted) 0…9 Use
    800H-DPH16AAXX64
      
    ★ Must order mounting bracket (Cat. No. 599-BRL) separately.
    ‡ For Type 1, lift-off, non-combination starters only (Bulletins 500, 500L, 505, and 509).

    Description Enclosure Type NEMA Size Cat. No.
    Click to enlarge - 500Line-1_112-1 Pilot Light Kits§ 
    120V
    1, 3R/4/12 0…5 599-PL09DJ
    120V 4, 4X (stainless steel and non-metallic) 599-PL09DS
    240V 1, 3R/4/12 599-PL09AJ
    240V 4, 4X (stainless steel and non-metallic) 599-PL09AS
    480V 1, 3R/4/12 599-PL09BJ
    480V 4, 4X (stainless steel and non-metallic) 599-PL09BS
    600V 1, 3R/4/12 599-PL09CJ
    600V 4, 4X (stainless steel and non-metallic) 599-PL09CS
    ON★ ‡ ∆  120V AC 1 (lift-off) 00…2 599-PLLD
    240V AC 599-PLLA
    Optional Pilot Light Lens Covers
    Red
    All 0…5 800T-N26R
    Green 800T-N26G
    Amber 800T-N26A
    Blue 800T-N26B
    Clear 800T-N26C
    White 800T-N26W
    ON (Unilock 120V) — Red‡ ♣  3R, 7 & 9
    (Unilock)
    0…5 1481-N56A120R
    ON (Unilock 120V) — Green‡ ♣  1481-N56A120G
    Click to enlarge - 500Line-1_112-2 Push-to-Test Pilot Light Kits§ 
    120V
    1, 3R/4/12 0…5 599-PT09DJ
    120V 4, 4X (stainless steel and non-metallic) 599-PT09DS
    240V 1, 3R/4/12 599-PT09AJ
    240V 4, 4X (stainless steel and non-metallic) 599-PT09AS
    480V 1, 3R/4/12 599-PT09BJ
    480V 4, 4X (stainless steel and non-metallic) 599-PT09BS
    600V 1, 3R/4/12 599-PT09CJ
    600V 4, 4X (stainless steel and non-metallic) 599-PT09CS
    Optional Push-to-Test
    Pilot Light Lens Covers

    Red
    All 0…5 800T-N40
    Green 800T-N41
    Amber 800T-N42
    Blue 800T-N43
    Clear 800T-N45
    White 800T-N44
      Mounting bracket‡  All lift-off pilot devices, Type 1 00…2 599-BRL
      
    ★ Must order mounting bracket (Cat. No. 599-BRL) separately.
    ‡ For Type 1, lift-off, non-combination starters only (Bulletins 500, 500L, 505, and 509).
    § Pilot light kits and push-to-test pilot light kits include one green and one red cover as standard.
    ♣ An adapter (Cat. No. 1481-N61) is required for each pilot light added to Size 3, 4, and 5 Unilock enclosures.
    ∆ Supplied with red lens only.
    Note:Bulletins 505 and 520 with two pilot lights are supplied in hinged enclosures, with or without control circuit transformers.

    Description Enclosure Type NEMA Size Cat. No.
      ON ‡  (Unilock) —
    Red Lens (120V)
    3R, 7 & 9
    (Unilock)
    0…5 1481-N56A120R
      ON ‡  (Unilock) —
    Green Lens (120V)
    1481-N56A120G
      Transformers for pilot lights
    240V, 60 Hz and 220V, 50 Hz★ 
    00…5 1481-NX1
    480V, 60 Hz and 440V, 50 Hz 1481-NX2
    600V, 60 Hz and 550V, 50 Hz 1481-NX3
    Click to enlarge - 500Line-1_113-1 Replacement Bulbs for all Pilot Lights
    120V coil voltage - incandescent
    Amber, green, red, or blue lens color
    800T-N169
    120V coil voltage - LED
    Amber lens color
    800T-N320A
    Green lens color 800T-N320G
    Red lens color 800T-N320R
    Blue lens color 800T-N320B
    240/480/600V coil voltage - incandescent
    Amber, green, red, or blue lens color
    800T-N65
    240/480/600V coil voltage - LED
    Amber lens color
    800T-N318A
    Green lens color 800T-N318G
    Red lens color 800T-N318R
    Blue lens color 800T-N318B
      Additional Pilot Devices
    Additional pilot devices
    1, 3R/4/12 0…9 Use Bulletin 800T devices
    (See Bulletin 800T/800H 30.5 mm Push Buttons)
    Additional pilot devices 4/4X, 4X 0…9 Use Bulletin 800H
    Type 4X devices
    (See Bulletin 800T/800H 30.5 mm Push Buttons)
    Additional pilot devices (bolted) 3R, 7 & 9 0…9 Use Bulletin 800H
    Type 7 & 9 devices
    (See Bulletin 800H/Hazardous Location Push Buttons)
      
    ★ When the control voltage is other than 120V, 60 Hz or 110V, 50 Hz it is necessary to also use one of the following transformers.
    ‡ An adaptor (Cat. No. 1481-N61) is required for each pilot light added to size 3, 4, and 5 Unilock enclosures.

    Enclosure Accessories

    For use on Bulletins 500, 500F, 500L, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1233X, and 1233V

    Description Enclosure Type NEMA Size Cat. No.
    Click to enlarge - 500Line-1_114-2 Non-metallic Conduit Connectors
    1/2 in. (12.7 mm)
    4, 4X (stainless steel and non-metallic) 0…1 1490-N1
    3/4 in. (19 mm) 1490-N9
    1 in. (24.5 mm) 1490-N10
    1-1/4 in. (31.75 mm) 2 1490-N11
    1-1/2 in. (38.1 mm) 3 1490-N5
    2 in. (50.8 mm) 4 1490-N6
    2-1/2 in. (63.5 mm) 1490-N7
    3 in. (76.2 mm) 5 1490-N8
    Click to enlarge - 500Line-1_114-3 Grounding Adapters
    1/2 in. (12.7 mm), #14…10 AWG
    4, 4X (stainless steel and non-metallic)‡  0…1 1490-N19
    3/4 in. (19 mm), #14…8 AWG 1490-N20
    1 in. (24.5 mm), #14…8 AWG 1490-N21
    1-1/4 in. (31.75 mm), #14…4 AWG 2 1490-N22
    1-1/2 in. (38.1 mm), #8…1/0 AWG 3 1490-N23
    2 in. (50.8 mm), #8…1/0 AWG 4 1490-N24
    2-1/2 in. (63.5 mm), #6…2/0 AWG 1490-N25
    3 in. (76.2 mm), #6…4/0 AWG 5 1490-N26
    Click to enlarge - 500Line-1_114-4 Handle Kits with Universal Link for
    Switch and Breaker

    Painted Metal
    5-1/2 in. base
    1, 3R, 3R/4/12★  0…4 1494F-M1
    Painted Metal
    7-1/2 in. base
    5 1494F-M2
    Stainless Steel
    5-1/2 in. base
    4/4X (stainless steel) 0…4 1494F-S1
    Stainless Steel
    7-1/2 in. base
    5 1494F-S2
    Nonmetallic Handle
    5-1/2 in. base
    1, 3R, 3R/4/12, 4/4X (non-metallic) 0…4 1494F-P1
    Click to enlarge - 500Line-1_114-5 Hole Plugs
    30.5 mm hole plug for pilot devices
    All 0…5 800T-N1
    Enclosure Hole Plugs 598-N1
      
    ★ For combination starters only.
    ‡ Bulletin 1490 grounding adapters are available for use with these conduit hubs. These bushings provide a convenient method of connecting a ground wire to the conduit system. See conduit connector (hub) above proper size.

    Description Enclosure Type NEMA Size Cat. No.
    Click to enlarge - 500Line-1_115-1 Door Safety Hardware Kits
    Enclosure Size (H x W x D)

    27 x 10 x 8.2 in.
    3R/4/12‡  0…2 1494F-V1
    30 x 20 x 9.7 in. 0…4 1494F-V2
    50 x 22 x 11.1 in. 3…4 1494F-V3
    56 x 30 x 14 in. 5 1494F-V4
      Breather
    Bulletin 505, 507, 509, and 513 — Unilock and bolted
    Class I, Groups C and D
    Class II, Groups E, F and G∆ § 
    0…5 1401-N1
    Drain
    Bulletin 505, 507, 509, and 513 — Unilock and bolted
    Class I, Groups C and D
    Class II, Groups E, F and G∆ § 
    1401-N2
    Breather Drain Combination♣ 
    Bulletin 505, 507, 509, and 513 — Unilock and bolted
    Class I, Groups C and D
    Class II, Groups E, F and G∆ § 
    1401-N3
    Click to enlarge - 1_102 Ground Lug Kits 0…2 599-GR1
    3…5 599-GR2
    6…7 599-GR3
      

    Description of Accessory Kit Size 0…2 Size 3 Size 4 Size 5 Size 6…9
    Cat. No. Cat. No. Cat. No. Cat. No. Cat. No.
    Reset Buttons (Each Kit Contains One Reset)          
    Type 1, 3R/12
    Bulletin 506…507 — One Kit Required Per Starter
    Bulletin 512…513 — One Kit Required Per Starter
    Bulletin 522…523 — Two Kits Required Per Starter
    1493-N21 1493-N21 1493-N31♠ 
    1493-N21◆ 
    Type 4/4X 1493-N32
    Pneumatic Timer Mounting Plate Adapter
    (For Mtg. Bulletin 849A Timer)
        Bulletin 509 and 513 — Unilock∆ 
    1401-N4
      
    ‡ Converts combination starter enclosure F to enclosure code D or J with door safety hardware.
    § Standard on bolted Type 3R, 7 & 9.
    ♣ The breather-drain combination can be in enclosure top as a breather or bottom as a drain. Specify (2) when both functions are required.
    ∆ Unilock suitable for Types 7 & 9 or Types 3R, 7 & 9 with the addition of a drain or a breather and drain.
    ◆ For Bulletins 512…513 only.
    ♠ Also use for NEMA sizes 0…2 lift-off enclosure.

    System Accessories

    For use on Bulletins 500, 500F, 500L, 500LP, 502, 502L, 503, 503L, 505, 505V, 506, 506X, 507, 507X, 509, 512, 512H, 512M, 512V, 513, 513H, 513M, 513V, 520, 520V, 522, 523, 530, 532, 533, 540, 542, 543, 570, 572, 573, 1242, 1243, 1272, 1273, 1282, 1283, 1232X, 1232V, 1233X, and 1233V

    Description Enclosure Type NEMA Size Cat. No.
    Click to enlarge - 500Line-1_116-1 Power Monitor Kit★ ‡ 
    3-phase, 240V AC —
    (Time Mark Model A258)
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 599-PM1
    3-phase, 480V AC —
    (Time Mark Model A258B)
    599-PM2
    Click to enlarge - 500Line-1_116-2 Terminal Block★ 
    Panel Mount (6 point)§ 
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 1492-HC6
    Click to enlarge - 500Line-1_116-3 Timing Relays★ 
    120V AC, ON-Delay — 8-pin socket
    (Cat. No. 700-HN125) required
    0.1…10 s
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 700-HT12AU120
    120V AC, ON-Delay — 8-pin socket
    (Cat. No. 700-HN125) required
    1.0…180 s
    700-HT12BU120
    120V AC, OFF-Delay — 11-pin socket
    (Cat. No. 700-HN126) required
    0.1…10 s
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 700-HT22AU120
    120V AC, OFF-Delay — 11-pin socket
    (Cat. No. 700-HN126) required
    1.0…180 s
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 700-HT22BU120
    Click to enlarge - 500Line-1_116-4 Control Relays★ 
    DPDT
    2-pole
    2 Form C
    Single AgNi Contact
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 700-HA32A1
    3PDT
    3-pole
    3 Form C
    Single AgNi Contact
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 700-HA33A1
    Click to enlarge - 500Line-1_116-5 Relay Sockets★ 
    8-pin socket
    1 (hinged), 3R, 3R/4/12, 4/4X (stainless) 0…7 700-HN125
    11-pin socket 0…7 700-HN126
      
    ★ For combination starters only.
    ‡ 3-phase power monitor kit includes the time mark phase monitor and socket.
    § Up to two 6-point terminal blocks may be added to each combination starter.

    Specifications

    Electrical Ratings

    NEMA
    Size
    Load
    Voltage
    [V]
    Continuous
    Current
    Rating
    [A]
    Service
    Limit
    Current
    Rating
    [A]★ 
    Maximum Hp Rating
    (Non-plugging and non-jogging duty)
    Maximum Hp Rating
    (Plugging and jogging duty)‡ 
    Transformer Primary
    Switching kVa Rating
    (Inrush Current
    £ 20 times
    Continuous
    Current)
    Transformer Primary
    Switching kVa Rating
    (Inrush Current = 20
    to 40 times
    Continuous Current)
    Capacitor
    Switching
    kVAR§ 
    Maximum
    Circuit
    Closing
    Inrush
    Current
    [A] Peak
    Including
    Offset
    1Æ 3Æ 1Æ 3Æ 1Æ 3Æ 1Æ 3Æ 3Æ 3Æ
    00 115
    200
    230
    380
    460
    575
    9 11 1/3

    1



    1-1/2
    1-1/2
    1-1/2
    2
    2
    1/4

    1/2



    1
    1
    1
    1-1/2
    1-1/2

























    87
    0 115
    200
    230
    380
    460
    575
    18 21 1

    2



    3
    3
    5
    5
    5
    1/2

    1



    1-1/2
    1-1/2
    1-1/2
    2
    2
    0.6

    1.2

    2.4
    3

    1.8
    2.1

    4.2
    5.2
    0.3

    0.6

    1.2
    1.5

    0.9
    1

    2.1
    2.6





    140
    1 115
    200
    230
    380
    460
    575
    27 32 2

    3



    7-1/2
    7-1/2
    10
    10
    10
    1

    2



    3
    3
    5
    5
    5
    1.2

    2.4

    4.9
    6.2

    3.6
    4.3

    8.5
    11
    0.6

    1.2

    2.5
    3.1

    1.8
    2.1

    4.3
    5.3


    6

    13.5
    17
    288
    1P 115
    230
    36 42 3
    5

    1-1/2
    3







    2 115
    200
    230
    380
    460
    575
    45 52 3

    7-1/2



    10
    15
    25
    25
    25
    2

    5



    7-1/2
    10
    15
    15
    15
    2.1

    4.1

    8.3
    10

    6.3
    7.2

    14
    18
    1

    2.1

    4.2
    5.2

    3.1
    3.6

    7.2
    8.9


    12

    25
    31
    483
    3 115
    200
    230
    380
    460
    575
    90 104 7-1/2

    15



    25
    30
    50
    50
    50
    7-1/2

    15



    15
    20
    30
    30
    30
    4.1

    8.1

    16
    20

    12
    14

    28
    35
    2

    4.1

    8.1
    10

    6.1
    7.0

    14
    18


    27

    53
    67
    947
    4 115
    200
    230
    380
    460
    575
    135 156





    40
    50
    75
    100
    100






    25
    30
    50
    60
    60
    6.8

    14

    27
    34

    20
    23

    47
    59
    3.4

    6.8

    14
    17

    10
    12

    23
    29


    40

    80
    100
    1581
    5 115
    200
    230
    380
    460
    575
    270 311





    75
    100
    150
    200
    200






    60
    75
    125
    150
    150
    14

    27

    54
    68

    41
    47

    94
    117
    6.8

    14

    27
    34

    20
    24

    47
    59


    80

    160
    200
    3163
    6 115
    200
    230
    380
    460
    575
    540 621





    150
    200
    300
    400
    400






    125
    150
    250
    300
    300
    27

    54

    108
    135

    81
    94

    188
    234
    14

    27

    54
    68

    41
    47

    94
    117


    160

    320
    400
    6326
    7 230
    460
    575
    810 932

    300
    600
    600












    240
    480
    600
    9470
    8 230
    460
    575
    1215 1400

    450
    900
    900












    360
    720
    900
    14205
    9 230
    460
    575
    2250 2590

    800
    1600
    1600












    665
    1325
    1670
    25380
      
    ★ Service-Limit Current Ratings — The service-limit current ratings shown represent the maximum rms current, in amperes, which the controller shall be permitted to carry for protracted periods in normal service. At service-limit current ratings, temperature rises shall be permitted to exceed those obtained by testing the controller at its continuous current rating. The current rating of overload relays or the trip current of other motor protective devices used shall not exceed the service-limit current rating of the controller.
    ‡ Plugging or Jogging Service — The listed horsepower ratings are recommended for those applications requiring repeated interruption of stalled motor current encountered in rapid motor reversal in excess of five openings or closings per minute and shall not be more than ten in a ten minute period.
    § If maximum available current (at capacitor terminals) is greater than 3000 A, please contact your local Rockwell Automation sales office, Allen-Bradley distributor, or NEMA ICS-2 Standard.

    Mechanical Ratings

    NEMA
    Size
    Mechanical Life
    (Millions of Operations)
    Maximum Number of
    Auxiliary Contacts
    Operating Time [ms]
    Pick-up (Average) Drop-out (Average)
    00 10 5 20 16
    0 10 8 21 16
    1 10 8 22 14
    1P 10 8 22 14
    2 10 8 27 13
    3 5 8 37 20
    4 5 8 27 20
    5 5 8 25 18
    6 5 4 25…79 10…22
    7 8 88 40
    8 8 88 45
    9 8 118 84
      

    Construction

    NEMA
    Size
    Wire Size for
    Power Terminals
    Required Torque on
    Power Terminal Wire
    Clamps and Pressure
    Connectors or Lugs
    Type of Power Terminal Contact Material Requirements
    for Sizing of Wire
    Power
    Contacts
    Auxiliary
    Contacts
    00 #16…10 AWG 9 lb•in Pressure terminals Silver alloy Silver All wire rated 167 °F
    (75 °C) or higher must
    be sized per the local
    Electrical Code for
    167°F (75 °C) wire.
    0 #14…10 AWG 20 lb•in Saddle or wire clamps
    1 #14…8 AWG 20 lb•in
    2 #14…4 AWG 45 lb•in Pressure terminals
    3 #8…1/0 AWG 150 lb•in
    4 #6…4/0 AWG 275 lb•in
    5 #4 AWG…500 MCM 375 lb•in
    6 Lugs sold separately.
    See Contactor Accessories .
    7
    8
    9 Direct bus connections only.
      

    Environmental

    NEMA
    Size
    Operating Position Operating Temperature Range Altitude Corrosion-Resistance
    00 Horizontal Starters with eutectic alloy
    Overload relay
    –13…+149 °F
    (–25…+65 °C)

    Starters with SMP
    Overload relay
    –13…+131 °F
    (–25…+55 °C)

    (provided condensation
    is prevented)
    10 000 feet before derating All metal parts are treated for
    corrosion-resistance
    0 Vertical
    1
    1P
    2
    3
    4
    5
    6 Horizontal
    7 Vertical
    8
    9
      

    Short Circuit Rating

    Combination contactors and starters with disconnect switch: Bulletin 502, 506, 512, 522E, 522F, 522G, and 1232X

    Combination Contactors and Starters with Disconnect Switch: Bulletin 502, 506, 512, 522E, 522F, 522G, and 1232X
    NEMA Size Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V]
    0…3 H, K 5000 600
    4…5 H, K 10 000
    0…5 J, R 100 000
    6 L 18 000
    7 L 18 000
    Combination Lighting Contactors with Disconnect Switch: Bulletin 502L
    Lighting Contactor Rating [A] Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V]
    20…100 H, K 5000 600
    200…300 H, K 10 000
    20…300 J, R 100 000
    Combination Contactors and Starters with Circuit Breaker: Bulletin 503, 507, 513, 523E, 523F, 523G, and 1233X★ 
    Enclosure Type NEMA Size Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V]
    1, 3R, 3R/4/12, 4/4X (stainless) 0…5 65 000 480
    Unilock 3R, 7, & 9 0…5 65 000
    Bolted 3R, 7, & 9 0…2 65 000
    1, 3R, 3R/4/12, 4/4X (stainless) 0…5 25 000 600
    Unilock 3R, 7, & 9 0…3 5000
    Unilock 3R, 7, & 9 4…5 10 000
    Bolted 3R, 7, & 9 0…2 5000
    3R, 3R/4/12 6…7 10 000
    Combination Lighting Contactors with Circuit Breaker: Bulletin 503L★ 
    Enclosure Type Lighting Contactor Rating [A] Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V]
    1, 3R, 3R/4/12, 4/4X (stainless) 20…300 65 000 480
    Unilock 3R, 7, & 9 20…300 65 000
    Bolted 3R, 7, & 9 20…300 65 000
    1, 3R, 3R/4/12, 4/4X (stainless) 20…300 25 000 600
    Unilock 3R, 7, & 9 20…100 5000
    Unilock 3R, 7, & 9 20…300 10 000
    Bolted 3R, 7, & 9 20…300 5000
        
    ★ For the most up-to-date SCCRs, please see the on-line Industrial Controls catalog at www.ab.com/catalogs.

    Combination Contactors and Starters with Disconnect Switch: Bulletin 502, 506, 512, 522E, 522F, 522G, and 1232X
    NEMA Size Fuse Type Available Short Circuit Amperes RMS Symmetrical [A] Maximum Voltage [V]
    0…3 H, K 5000 600
    4…5 H, K 10 000
    0…5 J, R 100 000
    6 L 18 000
    7 L 18 000
        

    AC Coil Data

    NEMA Size Operating Volt Amperes Burden [VA] Heat Dissipation [W] Coil Operating Limits
    60 Hz Coils
    Inrush Sealed
    00 70 8 2.7 85…110%
    0 192 29 5.9
    1 & 1P 192 29 5.9
    2 (2…3 poles) 240 29 5.9
    2 (4…5 poles) 315 38 5.9
    3 (2…3 poles) 660 45 10
    3 (4…5 poles) 840 58 10
    4 (2…3 poles) 1225 69 14.8
    4 (4…5 poles) 1490 96 14.8
    5 (Series L) 1490 96 19.8
    6★  4860 254 65.7
    6 (Interposing relay) 52.44 3.96
    7‡  Economized DC Coil
    7 (Interposing relay) 74.40 9.84
    8§  Economized DC Coil
    8 (Interposing relay) 74.40 9.84
    9♣  Economized DC Coil
    9 (Interposing relay) 144 19.20
      
    ★ This rating is for the size 6 contactor coil only. All starters are shipped with an interposing relay as standard.
    ‡ Size 7 starters are shipped with a 250 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for the contactor coil.
    § Size 8 starters are shipped with a 350 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for the contactor coil.
    ♣ Size 9 starters are shipped with a 750 VA control circuit transformer and an interposing relay with a 120V coil. Voltage is then rectified to DC for the contactor coil.

    Auxiliary Contacts (NEMA A600 and P300) — Bulletin 595, 596

    Maximum AC Contact Rating Per Pole
    AC Rating
    Designation
    Maximum Voltage
    60 or 50 Hz
    [A] Continuous
    Carrying Current
    [A]
    [VA]
    Make Break Make Break
    A600 120 60 6 10 7200 720
    240 30 3 10 7200 720
    480 15 1.5 10 7200 720
    600 12 1.2 10 7200 720
    Maximum DC Contact Rating Per Pole for 595, 596 Auxiliary Contacts (Maximum Continuous Carrying Current is 5 A)
    DC Rating
    Designation
    125V DC 250V DC 600V DC
    P300 0.55 A 0.55 A
    (Requires 2 Contacts in Series)
    1.1 A
    (Requires 2 Contacts in Series)
      

    Load-Life Curves

    Bulletin 500 Line contactors and starters are designed to provide superior performance in a variety of applications. These load-life curves are based on Rockwell Automation tests according to the requirements defined in IEC 947-4. Actual contact life may vary based on the application, duty cycle, and environmental conditions from that indicated by the curves.
    To find the contactor’s estimated electrical life, follow these guidelines:



    Contact Life for Mixed Utilization Categories AC3 and AC4

    In many applications, the utilization category cannot be defined as either purely AC3 or AC4. In those applications, the electrical life of the contactor can be estimated from the following equation:

    Click to enlarge - ContactLife_AC3_AC4_equation


    Where:

    Lmixed = Approximate contact life for a mixed AC3/AC4 utilization category application

    LAC3 = Approximate contact life in operations for AC3 utilization category (from AC3 life-load curves below)

    LAC4 = Approximate contact life in operations for AC4 utilization category (from AC4 life-load curves below)

    PAC4 = Percentage of AC4 operations


    Utilization Categories

    Category Typical Duty

    AC3 Starting of squirrel cage motors and switching off only after the motor is up to speed.

    AC4 Starting of squirrel cage motors with inching and plugging duty.


    Bulletin 500 Load/ Life Curves — AC3 and AC4

    Click to enlarge - 500Line-1_124-1


    Click to enlarge - 500Line-1_124-2

    Full Load Motor Currents

    3-Phase Motor Currents

    Full Load Currents of 3-Phase, 60 Hertz AC Induction Motors

    The full load currents listed below are “average values” for horsepower rated motors of several manufacturers at the more common rated voltages and speeds. These “average values”, along with the similar values listed in the U. S. National Electrical Code (NEC), should be used only as a guide for selecting suitable components for the Motor Branch Circuit. The rated full load current, shown on the motor nameplate, may vary considerably from the listed value depending on the specific motor design.

    ATTENTION: The motor nameplate full load current should always be used in determining the rating of the devices used for Motor Running Overcurrent Protection.

    HP RPM★  Full Load Current [A]
    208V 240V 480V 600V 2200V 4000V
    1/4 3600
    1800
    1200
    900
    1.20
    1.39
    1.62
    1.04
    1.20
    1.40
    0.52
    0.60
    0.70
    0.42
    0.48
    0.56






    1/3 3600
    1800
    1200
    900
    1.48
    1.69
    1.89
    1.28
    1.46
    1.64
    0.64
    0.73
    0.82
    0.51
    0.58
    0.66






    1/2 3600
    1800
    1200
    900
    2.08
    2.54
    2.89
    1.80
    2.20
    2.50
    0.90
    1.10
    1.25
    0.72
    0.88
    1.00






    3/4 3600
    1800
    1200
    900
    2.89
    3.47
    3.81
    2.50
    3.00
    3.30
    1.25
    1.50
    1.65
    1.00
    1.20
    1.32






    1 3600
    1800
    1200
    900
    3.51
    4.25
    4.60
    3.04
    3.68
    3.98
    1.52
    1.84
    1.99
    1.22
    1.47
    1.59






    1-1/2 3600
    1800
    1200
    900
    5.04
    5.80
    6.49
    4.36
    5.02
    5.62
    2.18
    2.51
    2.81
    1.74
    2.01
    2.25






    2 3600
    1800
    1200
    900
    6.51
    7.18
    8.20
    5.64
    6.22
    7.10
    2.82
    3.11
    3.55
    2.26
    2.49
    2.84






    3 3600
    1800
    1200
    900
    9.24
    10.4
    11.6
    8.00
    9.04
    10.1
    4.00
    4.52
    5.04
    3.20
    3.62
    4.03






    5 3600
    1800
    1200
    900
    15.7
    15.9
    18.6
    13.6
    13.8
    16.1
    6.80
    6.88
    8.07
    5.44
    5.50
    6.46






    7-1/2 3600
    1800
    1200
    900
    22.1
    25.0
    26.6
    19.1
    21.7
    23.1
    9.57
    10.8
    11.5
    7.66
    8.66
    9.22






    10 3600
    1800
    1200
    900
    29.7
    31.5
    32.9
    25.7
    27.3
    28.4
    12.9
    13.7
    14.2
    10.3
    10.9
    11.4






    15 3600
    1800
    1200
    900
    600
    43.0
    46.7
    49.1

    37.2
    40.4
    42.5

    18.6
    20.2
    21.3

    14.9
    16.2
    17.0









    20 3600
    1800
    1200
    900
    600
    59.2
    59.6
    61.7

    51.3
    51.6
    53.4

    25.6
    25.8
    26.7

    20.5
    20.6
    21.4

    5.2
    5.3
    5.4
    5.8
    6.4
    2.9
    3.0
    3.1
    3.2
    3.5
    25 3600
    1800
    1200
    900
    600
    70.9
    74.7
    76.0

    61.4
    64.7
    65.8

    30.7
    32.3
    32.9

    24.6
    25.9
    26.3

    6.3
    6.5
    6.7
    6.9
    8.1
    3.4
    3.6
    3.7
    3.8
    4.4
      
    ★ Synchronous speed nameplate is usually less due to slip.

    HP RPM★  Full Load Current [A]
    208V 240V 480V 600V 2200V 4000V
    50 3600
    1800
    1200
    900
    600
    141
    144
    147

    122
    125
    127

    61.2
    62.3
    63.4

    49.0
    49.8
    50.7


    12.3
    12.4
    13.1
    14.2

    6.8
    6.8
    7.2
    7.8
    60 3600
    1800
    1200
    900
    600
    165
    172
    173

    143
    149
    150

    71.6
    74.3
    74.9

    57.3
    59.4
    59.9


    14.6
    14.9
    15.4
    16.7

    8.0
    8.2
    8.5
    9.2
    75 3600
    1800
    1200
    900
    600
    204
    211
    215

    177
    183
    186

    88.5
    91.4
    93.1

    70.8
    73.1
    74.5


    18.0
    18.2
    19.0
    21.0

    9.9
    10.0
    10.5
    11.6
    100 3600
    1800
    1200
    900
    600
    450
    267
    276
    281


    231
    239
    243


    116
    119
    122


    92.6
    95.5
    97.2



    23.6
    24.2
    24.8
    26.4
    29.8

    13.0
    13.3
    13.6
    14.5
    16.4
    125 3600
    1800
    1200
    900
    720
    600
    450
    333
    340
    347



    288
    294
    300



    144
    147
    150



    115
    118
    120




    29.2
    29.9
    30.9
    31.3
    32.8
    36.0

    16.1
    16.4
    17.0
    17.2
    18.0
    19.8
    150 3600
    1800
    1200
    900
    720
    600
    450
    397
    404
    414



    344
    350
    358



    172
    175
    179



    138
    140
    143




    34.8
    35.5
    37.0
    37.0
    38.8
    42.0

    19.1
    19.5
    20.4
    20.4
    21.3
    23.1
    200 3600
    1800
    1200
    900
    720
    600
    450
    524
    531
    538



    454
    460
    466



    227
    230
    233



    182
    184
    186




    46.7
    47.0
    49.4
    49.0
    50.9
    53.7

    25.7
    25.9
    27.2
    27.0
    28.0
    29.5
    250 3600
    1800
    1200
    900
    720
    600
    450
    360
    642
    658
    682




    556
    570
    590




    278
    285
    295




    222
    228
    236





    57.5
    58.5
    61.5
    61.5
    61.0
    65.3
    70.0

    31.6
    32.2
    33.8
    33.8
    33.6
    35.9
    38.5
    300 3600
    1800
    1200
    900
    600
    450
    360
    774
    790
    804



    670
    684
    696



    335
    342
    348



    268
    274
    278




    69.0
    70.0
    73.5
    72.3
    76.0
    82.8

    38.0
    38.5
    40.4
    39.8
    41.8
    45.5
    350 3600
    1800
    1200


    748
    762
    774
    374
    381
    387
    299
    305
    310




    400 3600
    1800
    1200


    874
    892
    902
    437
    446
    451
    350
    357
    361




    450 3600
    1800
    1200


    972
    992
    1004
    486
    496
    502
    389
    397
    402




    500 3600
    1800
    1200


    1074
    1096
    1108
    537
    548
    554
    430
    438
    443




      

    Approximate Dimensions

    Approximate dimensions are shown in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes.

    Open Type without Enclosure for Bulletin 500 and 500F Contactors — NEMA sizes 0…4

    Click to enlarge - 500Line-1_127-1    Click to enlarge - 500Line-1_127-2a

    NEMA
    Size
    Number of
    Switching Poles
    Dimensions in Inches (Millimeters) Approximate
    Shipping
    Weight
    [lb (kg)]
    A
    Width
    B
    Height
    C
    Depth
    D E
    0…1 2…3 3-9/16
    (90.5)
    7-5/8
    (193)
    4-15/32
    (113)
    7-1/16
    (180)
    2-3/4
    (70)
    3
    (1.4)
    4 4-3/8
    (111)
    3-1/2
    (1.6)
    5 4-15/16
    (125)
    4-3/4
    (2.2)
    2 2…3 3-15/16
    (100)
    9-25/32
    (248)
    4-23/32
    (120)
    9-1/4
    (235)
    3-5/32
    (80)
    4
    (1.8)
    4 4-31/32
    (126)
    4-3/4
    (2.2)
    5 5-1/2
    (140)
    6-1/4
    (2.8)
    3 2…3 6-1/8
    (155.5)
    10-3/64
    (255)
    6-19/32
    (167.4)
    8-21/32
    (220)
    5-33/64
    (140)
    14.5
    (6.5)
    4 7-15/16
    (201.6)
    16
    (7.25)
    5 8-13/16
    (223.8)
    18
    (8)
    4 2…3 7
    (178)
    12-11/64
    (309)‡ 
    7-13/16
    (198.4)
    9-27/32
    (250)
    6-5/16
    (160)
    22
    (10)
    4 9-1/16
    (230.2)
    25.5
    (11.5)
    5 10-7/16
    (265.1)
    28.5
    (13)
      
    ‡ For Feed-Through Wiring this dimension is 11-11/16 in. (297 mm).

    Open Type without Enclosure for Bulletin 500FL, 500L, and 500LP and for NEMA sizes 00, 5…9 for Bulletin 500 and 500F Contactors

    Click to enlarge - 500Line-1_127-1    Click to enlarge - 500Line-1_127-2

    Note: Top mounting hole on Size 00 is 1/4 in. (6.35 mm) to the left of centerline on Open Type. Mounting screws: 3…#10 for sizes 0…2, 1/4…#20, or 5/16…#18 for sizes 3…5.

    NEMA
    Size
    Number of
    Switching Poles
    Dimensions in Inches (Millimeters) Approximate
    Shipping
    Weight
    [lb (kg)]
    Bulletin 500
    500F-500FL
    Bulletin
    500L-500LP
    A
    Width
    B
    Height
    C
    Depth
    D E
    00
    5/10A
    1-2-3 2…3 1-25/32
    (45)
    3-3/16
    (81)
    3-11/64
    (80.5)
    2-23/64
    (60)
    1-25/64
    (35)
    1
    (0.45)
    0…1
    15/20A
    30A
    2…3 2…3 3-9/16
    (90.5)
    6
    (152)★ 
    4-15/32
    (113)
    5-1/2
    (140)
    2-3/4
    (70)
    3
    (1.4)
    4 4-3/8
    (111)
    3-1/2
    (1.6)
    5 4 4-15/16
    (125)
    4-3/4
    (2.2)
    2
    60A
    2…3 2…3 3-15/16
    (100)
    6-27/32
    (173)★ 
    4-23/32
    (120)
    6-5/16
    (160)
    3-5/32
    (80)
    4
    (1.8)
    4 4-31/32
    (126)
    4-3/4
    (2.2)
    5 4 5-1/2
    (140)
    6-1/4
    (2.8)
    3
    100A
    2…3 2…3 6-1/8
    (155.5)
    10-3/64
    (255)
    6-19/32
    (167.4)
    8-21/32
    (220)
    5-33/64
    (140)
    14.5
    (6.5)
    4 7-15/16
    (201.6)
    16
    (7.25)
    5 4 8-13/16
    (223.8)
    18
    (8)
    4
    200A
    2…3 2…3 7
    (178)
    12-11/64
    (309)‡ 
    7-13/16
    (198.4)
    9-27/32
    (250)
    6-5/16
    (160)
    22
    (10)
    4 9-1/16
    (230.2)
    25.5
    (11.5)
    5 4 10-7/16
    (265.1)
    28.5
    (13)
    5
    300A
    2…3 2…3 7
    (178)
    13-25/64
    (340)§ 
    8-17/32
    (217)
    9-27/32
    (250)
    6-5/16
    (160)
    24
    (10.9)
      
    ★ For Feed-Through Wiring this dimension is 6-15/16 in. (176 mm).
    ‡ For Feed-Through Wiring this dimension is 11-11/16 in. (297 mm).
    § For Feed-Through Wiring this dimension is 12-37/64 in. (320 mm).

    Open Type without Enclosure for Bulletin 505 Full Voltage Reversing Starters with Eutectic Alloy Overload Relay

    Click to enlarge - 500Line-1_128-1


    NEMA
    Size
    Style Dimensions in Inches (Millimeters) Approx.
    Shipping
    Weight
    [lb (kg)]
    A
    Width
    B
    Height
    C
    Relay
    Reset Depth
    D E F G
    Depth
    00 With
    Eutectic
    Alloy
    Overload
    Protection
    4-7/8
    (124)
    6-9/16
    (167)
    3-27/32
    (98)
    6-1/64
    (153)
    4-3/8
    (111)
    4
    (1.8)
    0…1 8
    (203)
    9-5/32
    (233)
    4-11/16
    (119)
    8-21/32
    (220)
    7-3/32
    (180)
    4-5/8
    (117)
    10
    (4.5)
    2 9-1/16
    (230)
    10-11/32
    (263)
    4-11/16
    (119)
    9-27/32
    (250)
    7-7/8
    (200)
    4-29/32
    (125)
    12-3/4
    (5.8)
    3 12-7/8
    (327)
    12-29/64
    (316)
    6-21/64
    (161)
    9-27/32
    (250)
    11-13/16
    (300)
    11-13/16
    (300)
    6-55/64
    (174)
    34
    (15.5)
    4 14-27/32
    (377)
    14-5/8
    (371)
    6-23/32
    (171)
    11-13/16
    (300)
    13-25/32
    (350)
    13-25/32
    (350)
    8-5/64
    (205)
    52
    (24)
    5 14-27/32
    (377)
    17-55/64
    (453)
    8-35/64
    (217)
    16-15/16
    (430)
    13-25/32
    (350)
    13-25/32
    (350)
    8-13/16
    (224)
    65
    (29.5)
    6 23-13/32
    (594.5)
    25-5/64
    (637)
    10-9/16
    (268.5)
    11-27/64
    (290)
    7 31-1/2
    (800)
    32-13/16
    (833.4)
    12-9/32
    (311.9)
    8 35-1/4
    (896)
    36-7/8
    (937)
    12-9/32
    (311.9)
    9 For dimensions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
    00 Without
    Overload
    Protection
    4-7/8
    (124)
    4-5/16
    (110)
    2-3/16
    (55.6)
    3-3/4
    (95.3)
    4-3/8
    (111)
    2-3/4
    (1.2)
    0…1 8
    (203)
    7-19/32
    (193)
    7-3/32
    (180)
    7-3/32
    (180)
    4-5/8
    (117)
    8-3/4
    (4)
    2 9-1/16
    (230)
    8-3/8
    (213)
    7-7/8
    (200)
    7-7/8
    (200)
    4-29/32
    (125)
    11
    (5)
    3 12-7/8
    (327)
    10-21/32
    (271)
    9-27/32
    (250)
    11-13/16
    (300)
    11-13/16
    (300)
    6-55/64
    (174)
    30
    (13.5)
    4 14-27/32
    (377)
    12-23/32
    (323)
    11-13/16
    (300)
    13-25/32
    (350)
    13-25/32
    (350)
    8-5/64
    (205)
    47
    (21.3)
    5 14-27/32
    (377)
    12-23/32
    (323)
    11-13/16
    (300)
    13-25/32
    (350)
    13-25/32
    (350)
    8-13/16
    (224)
    47
    (21.3)
    6 23-13/32
    (594.5)
    17-1/16
    (433)
      11-27/64
    (290)
    7 31-1/2
    (800)
    32-13/16
    (833.4)
      11-11/32
    (288.1)
    8 35-1/4
    (896)
    36-7/8
    (937)
      11-13/16
    (300)
    9 For dimensions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.
      
    ★ Sizes 00…2 only.
    ‡ Sizes 3…5 only.

    Open Type without Enclosure for Bulletin 505V Full Voltage Reversing Starters with Solid State Overload Relay

    Click to enlarge - 500Line-1_131-1


    NEMA
    Size
    Overload
    Relay
    Dimensions in Inches (Millimeters) Approx. Shipping
    Weight
    [lb (kg)]
    A
    Width
    B
    Height
    C
    Depth
    D E F
    Relay Reset
    Depth
    G★ 
    0…1 E1 Plus
    Solid-State
    5-11/16
    (144)
    14-11/16
    (373)
    4-31/32
    (126)
    13-25/32
    (350)
    4-5/16
    (109)
    5
    (127)
    1/16
    (1.6)
    Size 0: 11.5 (5.2)
    Size 1: 12.2 (5.5)
    5-11/16
    (144)
    16-27/32
    (428)
    4-31/32
    (126)
    13-25/32
    (350)
    4-11/32
    (110)
    5-9/32
    (134)
    1/16
    (1.6)
    2 E1 Plus
    Solid-State
    6-1/8
    (156)
    17-1/16
    (434)
    5-7/32
    (133)
    15-3/4
    (400)
    4-23/32
    (120)
    5
    (127)
    1/4
    (6.4)
    14.5 (6.6)
    6-1/8
    (156)
    18-7/8
    (479)
    5-7/32
    (133)
    15-3/4
    (400)
    4-23/32
    (120)
    5-9/32
    (134)
    1/4
    (6.4)
    3 E1 Plus
    Solid-State
    7-17/32
    (192)
    25-1/8
    (639)
    7-19/32
    (193)
    21-21/32
    (550)
    5-29/32
    (150)
    7-1/16
    (179)
    1-3/32
    (28)
    57.4 (26.0)
    7-17/32
    (192)
    27-13/32
    (696)
    7-19/32
    (193)
    21-21/32
    (550)
    5-29/32
    (150)
    7-5/32
    (182)
    1-3/32
    (28)
    4 E1 Plus
    Solid-State
    8-5/32
    (208)
    29-3/32
    (739)
    8-13/16
    (224)
    25-19/32
    (650)
    6-23/32
    (171)
    7-15/32
    (190)
    2
    (51)
    86.0 (39.0)
    8-5/32
    (208)
    29-3/32
    (739)
    8-13/16
    (224)
    25-19/32
    (650)
    6-23/32
    (171)
    8-11/16
    (221)
    2-5/32
    (55)
    5 E1 Plus
    Solid-State
    8-7/16
    (215)
    37-7/8
    (962)
    9-17/32
    (242)
    36-31/32
    (939)
    6-11/16
    (170)
    9-9/32
    (236)
    2
    (51)
    112 (50.8)
    8-7/16
    (215)
    37-7/8
    (962)
    9-17/32
    (242)
    36-31/32
    (939)
    6-11/16
    (170)
    9-29/32
    (252)
    2
    (51)
      
    ★ Allow additional space for internal wiring.

    Open Type without Enclosure for Bulletin 509 Full Voltage Starters with Eutectic Alloy and Solid-State Overload Relay

    Click to enlarge - 500Line-1_132-1    Click to enlarge - 500Line-1_132-2
    Size 00 with Eutectic Alloy Overload Relay    Size 0…9
    Click to enlarge - 500Line-1_132-3
    Size 00 with Solid-State Overload Relay

    NEMA
    Size
    Dimensions in Inches (Millimeters) Approx. Shipping
    Weight
    [lb (kg)]
    A
    Width
    B
    Height
    C
    Relay Reset Depth
    D E
    00 ★  ★  ★  ★  ★  0.9 (0.4)
    0…1 3-9/16 (90.5) 7-5/8 (194) 4-1/2 (114) 7-3/32 (180) 2-3/4 (70) 4-1/4 (1.9)
    2 3-15/16 (100) 9-5/32 (233) 4-1/2 (114) 8-21/32 (220) 3-5/32 (80) 5-3/4 (2.6)
    3 6-11/64 (157) 12-29/64 (316) 6-1/16 (154) 8-21/32 (220) 5-33/64 (140) 15 (6.8)
    4 7 (178) 14-21/32 (372) 7-13/16 (198) 9-27/32 (250) 6-5/16 (160) 23-1/5 (10.6)
    5 7-3/8 (187) 16-7/6 (429) 8-17/32 (217) 14-32/32 (380) 6-5/16 (160) 35 (15.9)
    6 13-1/4 (337) 25-3/32 (637) 11-7/16 (291) 17-23/32 (450) 11-13/16 (300) 160 (72)
    7 16-1/2 (419) 30-27/32 (783) 12-9/32 (312) 18-5/16 (465) 15 (381) 247 (112)
    8 21-1/2 (546) 39-1/2 (1003) 15-19/32 (396) 22-5/8 (575) 20 (508) 370 (168)
    9 34 (864) 53-11/16 (1364) 28 (711)
      
    ★ See drawing for dimensions.

    Open Type without Enclosure for Bulletin 509 Full Voltage Starters with Solid-State Overload Relay

    Click to enlarge - 500Line-1_133-1


    NEMA
    Size
    Overload
    Relay
    Dimensions in Inches (Millimeters) Approx. Shipping
    Weight
    [lb (kg)]
    A
    Width
    B
    Height
    C
    Depth
    D E F
    Relay
    Reset Depth
    0…1 Solid-State
    E1 Plus
    3-9/16
    (91)
    7-5/8
    (193)
    4-15/32
    (113)
    7-1/16
    (180)
    2-3/4
    (70)
    4-1/2
    (114)
    4.3 (1.9)
    Solid-State
    E3 Plus
    3-9/16
    (91)
    9-25/32
    (248)
    4-15/32
    (113)
    9-1/4
    (235)
    2-3/4
    (70)
    4-5/8
    (118)
    2 Solid-State
    E1 Plus
    3-15/16
    (100)
    9-5/32
    (233)
    4-11/16
    (119)
    8-5/8
    (219)
    3-5/32
    (80)
    4-1/2
    (114)
    6.0 (2.7)
    Solid-State
    E3 Plus
    3-15/16
    (100)
    10-25/32
    (274)
    4-23/32
    (120)
    10-1/4
    (260)
    3-5/32
    (80)
    4-5/8
    (118)
    3 Solid-State
    E1 Plus
    6-1/8
    (156)
    12-7/16
    (316)
    6-19/32
    (168)
    8-21/32
    (220)
    5-1/2
    (140)
    6-1/16
    (154)
    16.0 (7.3)
    Solid-State
    E3 Plus
    6-1/8
    (156)
    14-9/16
    (370)
    6-19/32
    (168)
    8-21/32
    (220)
    5-1/2
    (140)
    5-61/64
    (151)
    4 Solid-State
    E1 Plus
    6-1/2
    (165)
    16-1/2
    (419)
    7-13/16
    (198)
    14-31/32
    (380)
    6-5/16
    (160)
    7-27/32
    (199)
    24.6 (11.2)
    Solid-State
    E3 Plus
    6-1/2
    (165)
    16-1/2
    (419)
    7-13/16
    (198)
    14-31/32
    (380)
    6-5/16
    (160)
    8-29/64
    (215)
    5 Solid-State
    E1 Plus
    6-1/2
    (165)
    16-29/32
    (429)
    8-11/32
    (212)
    14-31/32
    (380)
    6-5/16
    (160)
    7-5/8
    (194)
    33.9 (15.4)
    Solid-State
    E3 Plus
    6-1/2
    (165)
    16-29/32
    (429)
    8-11/32
    (212)
    14-31/32
    (380)
    6-5/16
    (160)
    8-11/64
    (208)
    6 Solid-State
    E1 Plus
    13-1/4
    (337)
    25-3/32
    (637)
    11-13/32
    (289)
    17-23/32
    (450)
    11-13/16
    (300)
    9-25/32
    (248)
    116 (52.6)
    Solid-State
    E3 Plus
    13-1/4
    (337)
    25-3/32
    (637)
    11-13/32
    (289)
    17-23/32
    (450)
    11-13/16
    (300)
    9-5/8
    (244)
      
    Note: For Bulletin 509 Size 00, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

    Open Type without Enclosure for Bulletin 520E, 520F, and 520G Multi-Speed Starters with Eutectic Alloy Overload Relay

    Click to enlarge - 500Line-1_134-1


    NEMA
    Size
    Dimensions in Inches (Millimeters) Approx.
    Shipping Weight
    [lb (kg)]
    A
    Width
    B
    Height
    C
    Depth
    D E F
    Relay
    Reset Depth
    G
    2-Speed Separate Winding Bulletin 520E
    0…1 8
    (203)
    9-5/32
    (233)
    4-11/16
    (119)
    8-21/32
    (220)
    7-3/32
    (180)
    4-5/8
    (117)
    11-1/4
    (5.1)
    2 9-1/16
    (230)
    10-11/32
    (263)
    4-11/16
    (119)
    9-27/32
    (250)
    7-7/8
    (200)
    4-29/32
    (125)
    13-3/4
    (6.2)
    3 12-7/8
    (327)
    12-29/64
    (316)
    6-21/64
    (161)
    9-27/32
    (250)
    11-13/16
    (300)
    6-1/16
    (154)
    6-55/64
    (174)
    34
    (15.3)
    4 14-27/32
    (377)
    15-1/64
    (381)
    6-23/32
    (171)
    11-13/16
    (300)
    13-25/32
    (350)
    7-13/16
    (198)
    8-5/64
    (205)
    54
    (24.3)
    5 16-13/16
    (427)
    17-55/64
    (453)
    8-35/64
    (217)
    16-15/16
    (430)
    15-3/4
    (400)
    8-17/32
    (217)
    8-13/16
    (224)
    82
    (36.9)
    2-Speed Consequent Pole Bulletin 520F and 520G
    0…1 9-5/16
    (236.5)
    9-5/32
    (233)
    4-11/16
    (119)
    8-21/32
    (220)
    7-3/32
    (180)
    4-5/8
    (117)
    12
    (5.4)
    2 10-1/4
    (260.4)
    10-11/32
    (263)
    4-11/16
    (119)
    9-27/32
    (250)
    7-7/8
    (200)
    4-29/32
    (125)
    15-1/4
    (7)
    3 16-1/4
    (413)
    12-29/64
    (316.3)
    6-21/64
    (161)
    9-27/32
    (250)
    13-25/32
    (350)
    6-1/16
    (154)
    6-55/64
    (174)
    44
    (19.8)
    4 18-7/32
    (463)
    14-39/64
    (371)
    6-23/32
    (171)
    11-13/16
    (300)
    15-3/4
    (400)
    7-13/16
    (198)
    8-5/64
    (205)
    63
    (28.4)
    5 18-11/32
    (466)
    17-55/64
    (453)
    8-35/64
    (217)
    16-15/16
    (430)
    15-3/4
    (400)
    8-17/32
    (217)
    8-13/16
    (224)
    85
    (38.6)
      

    Open Type Enclosure for Bulletin 520E, 520F, and 520G Multi-Speed Starters with Solid State Overload Relay

    Click to enlarge - 500Line-1_135-1


    NEMA
    Size
    Overload
    Relay
    Dimensions in Inches (Millimeters) Approx. Shipping
    Weight
    [lb (kg)]
    A Width B Height C Depth D E F Relay
    Reset Depth
    G
    2-Speed Separate Winding Bulletin 520E
    0…1 E1 Plus
    Solid-State
    8
    (203)
    9-5/32
    (233)
    4-5/8
    (118)
    8-21/32
    (220)
    7-3/32
    (180)
    4-11/16
    (118)
    3-3/16
    (81)
    11.3 (5.1)
    8
    (203)
    11-11/32
    (288)
    4-5/8
    (118)
    10-27/32
    (276)
    7-3/32
    (180)
    4-31/32
    (126)
    3-3/16
    (81)
    2 E1 Plus
    Solid-State
    9-1/16
    (230)
    10-11/32
    (263)
    4-29/32
    (125)
    9-27/32
    (250)
    7-7/8
    (200)
    4-11/16
    (118)
    4-11/32
    (110)
    14.9 (6.8)
    9-1/16
    (230)
    12-5/32
    (309)
    4-29/32
    (125)
    11-21/32
    (296)
    7-7/8
    (200)
    4-31/32
    (126)
    4-11/32
    (110)
    3 E1 Plus
    Solid-State
    12-7/8
    (327)
    12-13/32
    (315)
    6-7/8
    (175)
    9-27/32
    (250)
    11-13/16
    (300)
    6-11/32
    (161)
    35.6 (16.1)
    12-7/8
    (327)
    14-9/16
    (370)
    6-55/64
    (174)
    9-27/32
    (250)
    11-13/16
    (300)
    6-17/64
    (158)
    4 E1 Plus
    Solid-State
    14-27/32
    (377)
    14-7/16
    (365)
    8-3/32
    (205)
    11-13/16
    (300)
    13-25/32
    (350)
    6-23/32
    (171)
    61.0 (27.7)
    14-27/32
    (377)
    15-21/32
    (397)
    8-3/32
    (205)
    11-13/16
    (300)
    13-25/32
    (350)
    7-3/4
    (196.9)
    5 E1 Plus
    Solid-State
    16-13/16
    (427)
    17-7/8
    (454)
    8-13/16
    (224)
    16-15/16
    (430)
    15-3/4
    (400)
    8-9/16
    (217)
    93.5 (42.4)
    16-13/16
    (427)
    17-7/8
    (454)
    8-13/16
    (224)
    16-15/16
    (430)
    15-3/4
    (400)
    9-3/16
    (233)
    6 E1 Plus
    Solid-State
    23-13/32
    (595)
    25-3/32
    (637)
    11-27/64
    (290)
    17-23/32
    (450)
    21-31/32
    (558)
    10-37/64
    (269)
    254 (115)
    23-13/32
    (595)
    25-3/32
    (637)
    11-27/64
    (290)
    17-23/32
    (450)
    21-31/32
    (558)
    11-9/16
    (294)
    2-Speed Consequent Pole Bulletin 520F and 520G
    0…1 E1 Plus
    Solid-State
    9-5/16
    (237)
    9-5/32
    (233)
    4-5/8
    (117)
    8-21/32
    (220)
    7-3/32
    (180)
    4-11/16
    (118)
    3-9/16
    (91)
    12.0 (5.4)
    9-5/16
    (237)
    11-11/32
    (288)
    4-5/8
    (117)
    10-27/32
    (275)
    7-3/32
    (180)
    4-31/32
    (126)
    3-9/16
    (91)
    2 E1 Plus
    Solid-State
    10-1/4
    (260)
    10-11/32
    (263)
    4-29/32
    (125)
    9-27/32
    (250)
    7-7/8
    (200)
    4-11/16
    (118)
    4-3/4
    (121)
    15.6 (7.1)
    10-1/4
    (260)
    12
    (305)
    4-29/32
    (125)
    11-1/2
    (292)
    7-7/8
    (200)
    4-31/32
    (126)
    4-3/4
    (121)
    3 E1 Plus
    Solid-State
    16-1/4
    (413)
    12-3/4
    (324)
    6-7/8
    (175)
    9-27/32
    (250)
    13-25/32
    (350)
    6-11/32
    (161)
    45.0 (20.4)
    16-1/4
    (413)
    14-7/8
    (378)
    6-7/8
    (175)
    9-27/32
    (250)
    13-25/32
    (350)
    6-15/32
    (164)
    4 E1 Plus
    Solid-State
    18-7/32
    (463)
    14-27/32
    (377)
    8-3/32
    (205)
    11-13/16
    (300)
    15-3/4
    (400)
    6-3/4
    (172)
    73.0 (33.1)
    18-3/4
    (476)
    16-1/16
    (408)
    8-3/32
    (205)
    11-13/16
    (300)
    15-3/4
    (400)
    7-15/16
    (202)
    5 E1 Plus
    Solid-State
    18-11/32
    (466)
    17-7/8
    (454)
    8-13/16
    (224)
    16-15/16
    (430)
    15-3/4
    (400)
    8-9/16
    (217)
    131 (59.4)
    18-11/32
    (466)
    17-7/8
    (454)
    8-13/16
    (224)
    16-15/16
    (430)
    15-3/4
    (400)
    9-3/16
    (233)
        

    Open Type without Enclosure for Bulletin 520VE, 520VF, and 520VG Multi-Speed Starters with Eutectic Alloy Overload Relay

    Click to enlarge - 500Line-1_136-1


    NEMA Size Dimensions in Inches (Millimeters)
    A
    Width
    B
    Height
    C
    Depth
    D E
    Relay
    Reset
    Depth
    F G H J K Approx.
    Shipping
    Weight
    [lb (kg)]
    2-Speed Separate Winding Bulletin 520VE
    0…1 5-11/16
    (144.5)
    17-9/64
    (435.4)
    4-15/16
    (125.4)
    15-3/4
    (400)
    5
    (127)
    1-11/32
    (34.1)
    29/64
    (11.5)
    1-13/16
    (46)
    4-21/64
    (109.9)
    1/16
    (1.6)
    5.4
    (12)
    2 6-1/8
    (155.6)
    20-37/64
    (522.7)
    4-5/8
    (117.5)
    19-11/16
    (500)
    4-5/16
    (109.5)
    1-21/32
    (42.1)
    29/64
    (11.5)
    2-27/32
    (72.2)
    4-23/32
    (119.8)
    1/4
    (6.4)
    6.8
    (15)
    3 7-17/32
    (191.3)
    30-5/16
    (769.9)
    7-1/4
    (184.1)
    27-9/16
    (700.1)
    6-45/64
    (170.3)
    2-55/64
    (72.6)
    5/8
    (15.9)
    3-41/64
    (92.5)
    5-29/32
    (150)
    1-3/32
    (27.8)
    18.1
    (40)
    4 8-5/16
    (211.2)
    35-1/4
    (895.4)
    8-23/64
    (212.3)
    31-1/2
    (800.1)
    7
    (177.8)
    2-63/64
    (75.8)
    5/8
    (15.9)
    3-63/64
    (101.2)
    6-11/16
    (169.9)
    1-1/2
    (38.1)
    60-1/2
    (27.4)
    5 8-7/16
    (214.4)
    42-11/64
    (1071.1)
    9-17/32
    (242.1)
    41-17/64
    (1048.1)
    9-17/64
    (235.4)
    5-45/64
    (144.8)
    29/64
    (11.5)
    3-23/32
    (94.4)
    6-11/16
    (170)
    3
    (76.2)
    2-Speed Consequent Pole Bulletin 520VF/520VG
    0…1 6-3/64
    (164.7)
    17-1/2
    (444.5)
    4-15/16
    (125.4)
    15-3/4
    (400)
    5
    (127)
    1-11/32
    (34.1)
    29/64
    (11.5)
    2-63/64
    (75.8)
    5-1/8
    (130.2)
    33/64
    (13.1)
    13
    (5.9)
    2 6-29/32
    (175.4)
    20-37/64
    (522.7)
    4-5/8
    (117.5)
    19-11/16
    (500)
    4-5/16
    (109.5)
    1-21/32
    (42.1)
    29/64
    (11.5)
    31-19/64
    (83.7)
    5-33/64
    (140.1)
    23/32
    (18.1)
    16
    (7.3)
    3 9-1/8
    (231.8)
    30-5/16
    (777.9)
    7-1/4
    (184.1)
    27-9/16
    (700.1)
    6-45/64
    (170.3)
    2-55/64
    (72.6)
    5/8
    (15.9)
    5-23/64
    (136.2)
    7-31/64
    (190.1)
    2-1/8
    (54)
    45-1/2
    (20.7)
    4 10-9/32
    (261.1)
    35-1/4
    (895.4)
    8-23/64
    (212.3)
    31-1/2
    (800.1)
    7
    (177.8)
    2-63/64
    (75.8)
    5/8
    (15.9)
    5-61/64
    (151.2)
    8-21/32
    (219.9)
    3-7/32
    (81.8)
    72-1/2
    (32.9)
    5 11-29/32
    (302.4)
    42-11/64
    (1071.1)
    9-17/32
    (242.1)
    41-17/64
    (1048.1)
    9-17/64
    (235.4)
    5-45/64
    (144.8)
    13/32
    (10.3)
    5-11/16
    (144.4)
    8-21/32
    (220)
    4
    (101.6)
      
    ★ Allow additional space for internal wiring.

    Open Type without Enclosure for Bulletin 520VE, 520VF, and 520VG Multi-Speed Starters with Solid State Overload Relay

    Click to enlarge - 500Line-1_137-1


    Note: The typical drawing above shows 3-point mounting. Sizes 3…5 have 4-point mounting holes at each corner of the mounting plate.

    2-Speed Separate Winding Bulletin 520VE Approx. Shipping
    Weight
    [lb (kg)]
    NEMA
    Size
    Dimensions in Inches (Millimeters)
    Overload
    Relay
    A
    Width
    B
    Height
    C
    Depth
    D E F
    Relay Reset
    Depth
    G★ 
    0…1 E1 Plus
    Solid-State
    5-11/16
    (145)
    17-1/4
    (438)
    4-15/16
    (126)
    15-3/4
    (400)
    4-5/16
    (109)
    5
    (127)
    1/16
    (1.6)
    12.7 (5.3)
    5-11/16
    (145)
    21-1/2
    (546)
    4-15/16
    (126)
    15-3/4
    (400)
    4-11/32
    (110)
    5-9/32
    (134)
    1/16
    (1.6)
    2 E1 Plus
    Solid-State
    6-1/8
    (156)
    20-9/16
    (522)
    4-5/8
    (118)
    19-11/16
    (500)
    4-23/32
    (120)
    4-15/16
    (125.5)
    1/4
    (6.4)
    16.0 (7.3)
    6-1/8
    (156)
    23-13/16
    (605)
    4-5/8
    (118)
    19-11/16
    (500)
    4-23/32
    (120)
    5-9/32
    (134)
    1/4
    (6.4)
    3 E1 Plus
    Solid-State
    7-17/32
    (192)
    31-1/16
    (789)
    7-19/32
    (193)
    27-9/16
    (700)
    5-29/32
    (150)
    7-1/16
    (179.4)
    1-3/32
    (28)
    74.8 (33.9)
    7-17/32
    (192)
    35-9/16
    (903)
    7-19/32
    (193)
    34-23/32
    (882)
    5-29/32
    (150)
    7-5/32
    (182)
    1-3/32
    (28)
    4 E1 Plus
    Solid-State
    8-5/16
    (208)
    35
    (889)
    8-13/16
    (224)
    31-1/2
    (800)
    6-11/16
    (170)
    7-15/32
    (190)
    1-1/2
    (38)
    98.0 (44.4)
    8-5/16
    (208)
    37-23/32
    (958)
    8-13/16
    (224)
    36-13/16
    (935)
    6-11/16
    (170)
    8-23/32
    (222)
    1-1/8
    (29)
    5 E1 Plus
    Solid-State
    8-7/16
    (215)
    42-3/16
    (1072)
    9-17/32
    (242)
    41-9/32
    (1049)
    6-11/16
    (170)
    9-9/32
    (236)
    3
    (76)
    113 (51.2)
    8-7/16
    (215)
    42-3/16
    (1072)
    9-17/32
    (242)
    41-9/32
    (1049)
    6-11/16
    (170)
    9-9/32
    (236)
    3
    (76)
      
    ★ Allow additional space for internal wiring.

    Open Type without Enclosure for Bulletin 520VE, 520VF, and 520VG Multi-Speed Starters with Solid State Overload Relay, Continued

    Click to enlarge - 500Line-1_138-1


    2-Speed Consequent Pole Bulletin 520VF and 520VG Approx. Shipping
    Weight
    [lb (kg)]
    NEMA
    Size
    Overload
    Relay
    Dimensions in Inches (Millimeters)
    A
    Width
    B
    Height
    C
    Depth
    D E F
    Relay Reset
    Depth
    G★ 
    0…1 E1 Plus
    Solid-State
    6-5/8
    (168)
    17-1/2
    (444.5)
    4-15/16
    (126)
    15-3/4
    (146)
    5-1/8
    (130)
    5
    (127)
    1/2
    (13)
    12.7 (5.8)
    7
    (177)
    22-11/16
    (576)
    4-15/16
    (126)
    15-3/4
    (146)
    5-1/8
    (130)
    5-9/32
    (134)
    17/32
    (13)
    2 E1 Plus
    Solid-State
    6-29/32
    (176)
    20-19/32
    (523)
    4-5/8
    (118)
    19-11/16
    (500)
    5-17/32
    (141)
    4-5/16
    (110)
    3/4
    19)
    16.0 (7.3)
    6-29/32
    (176)
    23-13/16
    (605)
    4-5/8
    (118)
    19-11/16
    (500)
    5-17/32
    (141)
    5-9/32
    (134)
    3/4
    19)
    3 E1 Plus
    Solid-State
    9-1/8
    (232)
    31-1/16
    (789)
    7-19/32
    (193)
    27-9/16
    (700)
    7-1/2
    (191)
    7-1/16
    (179)
    2-1/8
    (54)
    74.8 (33.9)
    10-3/32
    (256)
    35-9/16
    (903)
    7-19/32
    (193)
    34-23/32
    (882)
    7-1/2
    (191)
    7-5/32
    (182)
    1-25/32
    (29)
    4 E1 Plus
    Solid-State
    11-23/32
    (298)
    35
    (889)
    8-13/16
    (224)
    31-1/2
    (800)
    8-21/32
    (220)
    7-15/32
    (190)
    3-7/32
    (82)
    98.0 (44.4)
    11-23/32
    (298)
    37-23/32
    (958)
    8-13/16
    (224)
    36-13/16
    (935)
    8-21/32
    (220)
    8-23/32
    (222)
    1-25/32
    (29)
    5 E1 Plus
    Solid-State
    11-29/32
    (303)
    42-3/16
    (1072)
    9-17/32
    (242)
    41-9/32
    (1049)
    8-21/32
    (220)
    9-9/32
    (236)
    4
    (102)
    113 (51.2)
    11-29/32
    (303)
    42-3/16
    (1072)
    9-17/32
    (242)
    41-9/32
    (1049)
    8-21/32
    (220)
    9-9/32
    (236)
    4
    (102)
      
    ★ Allow additional space for internal wiring.

    Type 1 General Purpose Lift-Off Enclosure for Bulletins 500, 500L, & 509 Contactors & Starters 3-Pole

    Click to enlarge - 500_Type1_GenPurp_dim


    NEMA Size/
    Current Rating
    Bulletin No. Dimensions in Inches (Millimeters)
    A
    Width
    B
    Height
    C
    Depth
    D E F G H J K L
    00…1 500 & 509 6.84
    (174)
    9.76
    (248)
    5.52
    (140)
    6.16
    (156)
    1.04
    (26)
    1.88
    (48)
    6.42
    (163)
    1.66
    (42)
    1.04
    (26)
    1.45
    (37)
    3.42
    (87)
    5/10 A
    15/20 A
    30 A
    500L
    2 500 & 509 7.35
    (187)
    12.91
    (328)
    5.53
    (140)
    6.24
    (158)
    1.27
    (32)
    2.38
    (60)
    8.88
    (226)
    1.94
    (49)
    1.27
    (32)
    1.49
    (38)
    3.68
    (93)
    60 A 500L
      

    Type 1 Hinged Enclosure — with or without Control Transformer for Bulletins 500, 500L, 500LP, 505, 509, 520E, 520F, & 520G Contactors & Starters 3-…5-Pole

    Click to enlarge - 500_Type1_Hinged_dim


    NEMA Size/
    Current Rating
    Bulletin No. Dimensions in Inches (Millimeters)
    A
    Width
    B
    Height
    C
    Depth
    D E
    Mounting
    F
    Mounting
    G
    Mounting
    H J
    (Mounting)
    00…1 500 & 509 10.00
    (254)
    15.00
    (381)
    6.39
    (162)
    5.82
    (148)
    5.00
    (127)
    3.75
    (95)
    7.50
    (191)
    1.08
    (27)
    12.75
    (324)
    15…30 A 500L & 500LP
    2 500 & 509 14.00
    (356)
    18.00
    (457)
    6.39
    (162)
    5.83
    (148)
    7.00
    (178)
    5.75
    (146)
    11.50
    (292)
    1.00
    (25)
    15.75
    (400)
    60 A 500L & 500LP
    0…1 505 & 520
    3 500 & 509 13.00
    (330)
    22.00
    (559)
    8.50
    (216)
    7.89
    (201)
    6.50
    (165)
    5.25
    (133)
    10.50
    (267)
    1.08
    (27)
    19.75
    (502)
    100 A 500L & 500LP
    2 505 & 520
      
    Note: For Types 3R/12, 4/4X, 4X, and Bolted Type 7 & 9 and 3R, 7 & 9 dimensions, please contact your local Rockwell Automation sales office or Allen-Bradley distributor.

    Type 3R/12, 4/4X Enclosure — with or without Control Transformer for Bulletins 500, 500L, 505, 509, 520E, 520F, & 520G Contactors & Starters 3-…5-Pole

    Click to enlarge - 500_Type 3R_12_4_4X_dim


    NEMA Size/
    Current Rating
    Bulletin No. Approximate Dimensions In Inches (Millimeters)
    A
    Width
    B
    Height
    C
    Depth
    D E
    Mounting
    F
    Mounting
    G
    Mounting
    H J
    Mounting
    00…1 500 & 509 10.00
    (254)
    15.00
    (381)
    6.45
    (164)
    5.82
    (148)
    5.00
    (127)
    3.00
    (76)
    6.00
    (152)
    17.23
    (438)
    16.38
    (416)
    15…30 A 500L & 500LP
    2 500 & 509 14.00
    (356)
    18.00
    (457)
    6.45
    (164)
    5.83
    (148)
    7.00
    (178)
    5.00
    (127)
    10.00
    (254)
    20.23
    (514)
    19.38
    (492)
    60 A 500L & 500LP
    0…1 505 & 509
    3 500 & 509 13.00
    (330)
    22.00
    (559)
    8.57
    (218)
    7.89
    (201)
    6.50
    (165)
    4.43
    (113)
    9.00
    (229)
    24.23
    (615)
    23.38
    (594)
    100 A 500L & 500LP
    2 505 & 520
      

    Type 1 (Enclosure Code "A") General Purpose Painted Enclosure for Bulletins 500, 500L, 502, 502L, 503, 503L, 505, 506, 506X, 507, 507X, 509, 512, 512M, 512V, 513, 513M, 513V, 520E, 520F, 520G, 522E, 522F, 522G, 523E, 523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572 and 573

    Click to enlarge - 500Line-1_143-1
    Size 1…4 Size 5


    NEMA Size Bulletin No. Approximate Dimensions in Inches (Millimeters) Approx.
    Shipping
    Weight
    [lb (kg)]
    A
    Height
    B
    Width
    C
    Depth
    D
    Mounting
    E
    Mounting
    F
    Mounting
    G
    Handle Depth
    0...2 506X, 507X 27.50
    (968)
    10.50
    (267)
    8.25
    (210)
    25.13
    (639)
    ★  5.25
    (133)
    5.56
    (141)
    40
    (18.14)
    0...2 502, 502L, 503, 503L,
    512, 513
    0...2 506, 507, 512M, 513M,
    522E, 522F, 522G, 523E,
    523F, 523G
    30
    (762)
    20.5
    (521)
    9.88
    (251)
    27.63
    (702)
    15.25
    (387)
    15.25
    (387)
    5.56
    (141)
    90
    (40.82)
    3 502, 502L, 503, 503L,
    505, 512, 513, 520E,
    520F, 520G
    4 500, 500L, 503, 503L, 509, 513
    1PW, 2PW 530, 532, 533
    1YD 540, 542, 543
    3 506, 507, 522E, 522F,
    522G, 523E, 523F, 523G
    50
    (1270)
    22
    (559)
    11.19
    (284)
    47.63
    (1210)
    15.25
    (387)
    15.25
    (387)
    5.56
    (141)
    250
    (113.4)
    4 500LP, 505, 506, 507,
    520E, 520F, 520G, 522E,
    522F, 522G, 523E, 523F,
    523G
    502, 502L, 512
    5 500, 500L, 505, 509,
    520E, 520F, 520G
    3PW 530, 532, 533
    2YD, 3YD 540, 542, 543
    2 570, 572, 573
    5 502, 502L, 503, 503L,
    506, 506X, 507, 507X,
    512, 513, 523E, 523F,
    523G
    56
    (1422)
    30.5
    (775)
    13.79
    (350)
    57.63
    (1463)
    20
    (508)
    25.25
    (641)
    7.62
    (194)
    360
    (163.3)
    6 500, 500L,505, 509,
    520E
    4PW 530, 532, 533
    5PW 532, 533
    4YD 540, 542, 543
    3, 4 570, 572, 573
    5YD 540, 542, 543 60
    (1524)
    37.38
    (949)
    16.00
    (406)
    61.69
    (1567)
    33.88
    (861)
    33.88
    (861)
    7.62
    (194)
    420
    (190.5)
    5, 6 570, 572, 573
    5 522E, 522F, 522G
    5PW 530
      
    ★ Sizes 0, 1, and 2 have one top mounting hole located on the center line. Larger size enclosures have two top mounting holes located as shown.

    Type 3R/4/12 (Enclosure Codes "D", "F", and "J") Rainproof, Dusttight — Industrial Use Enclosures for Bulletins 500, 500L, 502, 502L, 503, 503L, 505, 506, 506X, 507, 507X, 509, 512, 512M, 512V, 513, 513M, 513V, 520E, 520F, 520G, 522E, 522F, 522G, 523E, 523F, 523G, 530, 532, 533, 540, 542, 543, 570, 572 and 573

    Click to enlarge - 500Line-1_144-1


    NEMA
    Size
    Bulletin No. Approximate Dimensions in Inches (Millimeters) Approx.
    Shipping
    Weight
    [lb (kg)]
    A
    Height
    B
    Width
    C
    Depth
    D
    Mounting
    E
    Mounting
    F
    Mounting
    G
    Handle
    Depth
    H J
    0...2 506X, 507X 27.50
    (698)
    10.50
    (267)
    8.25
    (210)
    28.88
    (733)
    ★  5.25
    (133)
    5.56
    (141)
    29.88
    (759)
    0.81
    (21)
    40
    (18.14)
    502, 507, 503, 503L,
    512, 513
    506, 507, 512M, 513M,
    522E, 522F, 522G, 523E,
    523F, 523G
    30
    (762)
    20.5
    (521)
    10.19
    (259)
    31.38
    (797.05)
    15.25
    (387)
    15.25
    (387)
    5.56
    (141)
    32.38
    (822)
    0.81
    (21)
    90
    (40.82)
    3 502, 507, 503, 503L,
    505, 512, 513, 520E,
    520F, 520G
    4 500, 500L, 509, 513
    1PW, 2PW 530, 532, 533
    1YD 540, 542, 543
    3 506, 507, 522E, 522F,
    522G, 523E, 523F, 523G
    50
    (1270)
    22
    (559)
    11.5
    (292)
    51.38
    (1305)
    15.25
    (387)
    15.25
    (387)
    5.56
    (141)
    52.38
    (1330)
    0.71
    (18)
    250
    (113.4)
    4 500LP, 502, 502L, 505,
    507, 512, 520E, 520F,
    520G, 522E, 522F, 522G,
    523E, 523F, 523G
    5 500, 500L, 509, 520E,
    520F, 520G
    3PW 530, 532, 533
    2YD, 3YD 540, 542, 543
    2 570, 572, 573
    4PW 530, 532, 533 56
    (1422)
    30.5
    (775)
    13.79
    (350)
    57.63
    (313)
    20
    (508)
    25.25
    (641)
    7.62
    (194)
    62.62
    (1590)
    1
    (25.4)
    360
    (163.3)
    5PW 532, 533
    4YD 540, 542, 543
    3, 4 570, 572, 573
    5 502, 502L, 503, 503L,
    506, 512, 513,
    523E, 523F, 523G
    6 500, 500L, 505, 509,
    512‡ , 513, 520E
    6 512§  60
    (1524)
    37.38
    (949)
    16
    (906)
    61.69
    (1567)
    33.88
    (861)
    33.88
    (861)
    7.62
    (194)
    63.5
    (1613)
    1.5
    (38)
    420
    (190.5)
    5 522E, 522F, 522G
    5PW 530
    5YD 540, 542, 543
    5, 6 570, 572, 573
    7 512, 513 84
    (2134)
    39.5
    (1003)
    18
    (457)
    7.62
    (194)
    650
    (249.8)
      
    ★ Sizes 0, 1, and 2 have one top mounting hole located on the center line. All sizes in large enclosures have two top mounting holes located as shown.
    ‡ Fusible disconnect switch with Class J fuses.
    § Fusible disconnect switch with Class R fuses.

    Type 3R (Enclosure Code "N") Rainproof. Enclosures with Extra Panel Space Bulletins 1232X, 1233X, 1242, 1243, 1272, 1273, 1282, 1283

    Click to enlarge - 1_127


    NEMA
    Size
    Bulletin No. Approximate Dimensions in Inches (Millimeters) Approx.
    Shipping
    Weight
    [lb (kg)]
    A
    Height
    B
    Width
    C
    Depth
    D
    Mounting
    E
    Mounting
    F
    Mounting
    G
    Handle
    Depth
    H J
    1...2 1232X 30
    (762)
    20.5
    (521)
    8.72
    (221)
    34.88
    (886)
    10
    (254)
    10
    (254)
    5.56
    (141)
    36.38
    (924)
    90
    (40.82)
    1…2 1233X
    3…4 1232X, 1233X 50
    (1270)
    22
    (559)
    9.90
    (251)
    54.88
    (1394)
    15.25
    (387)
    15.25
    (387)
    5.56
    (141)
    56.38
    (1432)
    250
    (113.4)
    1PW, 2PW 1282, 1283
    1YD, 2YD 1242, 1243
    2 1272, 1273
    4 1232X
    3PW, 4PW 1282 56
    (1422)
    30.5
    (775)
    13.78
    (350)
    11
    (279)
    40.72
    (1034)
    7.62
    (194)
    360
    (163.3)
    3PW…5PW 1283
    3YD, 4YD 1242
    3YD…5YD 1243
    3, 4 1272
    3…5 1273
    5 1232X, 1233X 56
    (1422)
    30.5
    (775)
    13.78
    (350)
    65.68
    (1668)
    11
    (279)
    33.84
    (860)
    7.62
    (194)
    9.68
    (246)
    360
    (163.3)
    6 1233X
    5PW 1282
    5YD 1242
    5, 6 1272
    6 1273
    6 1232X★ 
    6 1232X‡  60
    (1524)
    37.38
    (949)
    16
    (406)
    69.68
    (1769.9)
    11
    (279)
    40.72
    (1034)
    7.62
    (194)
    9.68
    (246)
    420
    (190.5)
    7 1232X, 1233X 84
    (2134)
    39.5
    (1003)
    18
    (457)
    93.68
    (2379.5)
    11
    (279)
    42.84
    (1088)
    7.62
    (194)
    9.68
    (246)
    650
    (294.8)
      
    ★ Fusible disconnect switch with Class J fuses.
    ‡ Fusible disconnect switch with Class R fuses.

    Type 3R (Enclosure Code "N") Rainproof Enclosures with Extra Panel Space — for Bulletins 1232X and 1233X

    Click to enlarge - 500Line-1_148-1


    Bulletin No. NEMA Size Approximate Dimensions in Inches (Millimeters)
    N P R T
    Inside Outside Inside Outside Inside Outside Inside Outside
    1232X
    1233X
    1 1-3/8 (35)
    1 in. Hub
    1-23/32 (44)
    1-1/4 in. Hub
    7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-23/32 (44)
    1-1/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    2
    3 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    2-15/32 (63)
    2 in. Hub
    1-3/8 (35)
    1 in. Hub
    1-3/8 (35)
    1 in. Hub
    1-23/32 (44)
    1-1/4 in. Hub
    4
    5 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    2-15/32 (63)
    2 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    2-15/32 (63)
    2 in. Hub
      

    Bulletin No. NEMA Size Approximate Dimensions in Inches (Millimeters)
    U V W
    Inside Outside Inside Outside Inside Outside
    1232X
    1233X
    1 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    2
    3 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    2-15/32 (63)
    2 in. Hub
    3 (76)
    2-1/2 in. Hub
    3 (76)
    2-1/2 in. Hub
    4
    5 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    3 (76)
    2-1/2 in. Hub
    3-5/8 (96)
    3 in. Hub
    3 (76)
    2-1/2 in. Hub
    3-5/8 (96)
    3 in. Hub
      

    Type 3R (Enclosure Code "N") Rainproof - Narrow Enclosure for Bulletins 1232 and 1233

    Click to enlarge - 1232_dim


    NEMA
    Size
    Approximate Dimensions in Inches (Millimeters) Approx.
    Shipping
    Weight
    [lb (kg)]
    A
    Height
    B
    Width
    C
    Depth
    D
    Mounting
    E
    Mounting
    F
    Mounting
    G
    Handle
    Depth
    H
    1...2 27.50
    (698)
    10.5
    (267)
    8.26
    (210)
    28.88
    (733)
    ★  7
    (178)
    5.56
    (141)
    29.75
    (756)
    40
    (18.14)
    3 30
    (762)
    20.5
    (521)
    8.72
    (221)
    34.88
    (886)
    10
    (254)
    10
    (254)
    5.56
    (141)
    36.38
    (924)
    90
    (40.82)
      
    ★ Sizes 1 and 2 have one top mounting hole located on the center line. All sized in large enclosures have two top mounting holes located as shown.

    Type 3R (Enclosure Code "N") Rainproof Narrow Enclosures — for Bulletins 1232 and 1233

    Click to enlarge - 500Line-1_148-1


    Bulletin No. NEMA Size Approximate Dimensions in Inches (Millimeters)
    N P R T
    Inside Outside Inside Outside Inside Outside Inside Outside
    1232
    1233
    1 1-3/8 (35)
    1 in. Hub
    1-23/32 (44)
    1-1/4 in. Hub
    7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-23/32 (44)
    1-1/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    2
    3 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    2-15/32 (63)
    2 in. Hub
    1-3/8 (35)
    1 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    1-3/8 (35)
    1 in. Hub
    1-23/32 (44)
    1-1/4 in. Hub
      

    Bulletin No. NEMA Size Approximate Dimensions in Inches (Millimeters)
    U V W
    Inside Outside Inside Outside Inside Outside
    1232
    1233
    1 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    2
    3 7/8 (22)
    1/2 in. Hub
    1-1/8 (29)
    3/4 in. Hub
    1-31/32 (50)
    1-1/2 in. Hub
    2-15/32 (63)
    2 in. Hub
    3 (76)
    2-1/2 in. Hub
    3 (76)
    2-1/2 in. Hub
      

    Type 4/4X (Enclosure Codes "C") Stainless Steel — Industrial Use Enclosures for Bulletins 500, 500L, 502, 502L, 503, 503L, 505, 506, 507, 509, 512, 512M, 513, 513M, 520E, 520F, 520G, 522E, 522F, 522G, 523E, 523F, and 523G

    Click to enlarge - 500Line-1_145-1


    NEMA Size Bulletin No. A
    Height
    B
    Width
    C
    Depth
    D
    Mounting
    E
    Mounting
    F
    Mounting
    G
    Handle
    Depth
    H J Approx. Shipping Weight [lb (kg)]
    0...2 502, 502L, 503, 503L, 512, 513 27.50
    (698)
    10.50
    (267)
    8.25
    (210)
    28.88
    (733)
    ★  7
    (178)
    5.56
    (141)
    29.75
    (756)
    0.81
    (21)
    40
    (18.14)
    0...2 506, 507, 512M, 513M, 522E, 522F, 522G, 523E, 523F, 523G, 30
    (762)
    20.5
    (521)
    9.88
    (251)
    31.38
    (797)
    17
    (432)
    17
    (432)
    5.56
    (141)
    32.26
    (819)
    0.81
    (21)
    90
    (40.82)
    3 502, 502L, 503, 503L, 505, 512, 513, 520E, 520F, 520G
    4 500, 500L, 503, 503L, 509, 513
    3 506, 507, 522E, 522F, 522G, 523E, 523F, 523G 50
    (1270)
    22
    (559)
    11.19
    (284)
    51.38
    (1305)
    18.5
    (470)
    18.5
    (470)
    5.56
    (141)
    52.26
    (1327)
    0.81
    (21)
    250
    (113.4)
    4 500LP, 502, 502L, 505, 506, 507, 512, 520E, 520F, 520G, 522F, 523G, 523E, 523F, 523G
    5 500, 500L, 505, 509, 520E, 520F, 520G
    5…6 503, 503L 507, 513, 523E, 523F, 523G 56
    (1422)
    30.5
    (775)
    12.34
    (313)
    57.63
    (1464)
    20
    (508)
    25.25
    (641)
    5.56
    (141)
    58.62
    (1489)
    1
    (25.4)
    360
    (163.3)
    5 512 7.62
    (194)
    6 500, 500L, 505, 509, 512‡ , 520E
    5…6 502, 502L 506
      
    ★ Sizes 0, 1, and 2 have one top mounting hole located on the center line. All sizes in large enclosures have two top mounting holes located as shown.
    ‡ Fusible disconnect switch with Class J fuses.

    Type 12 (Enclosure Codes "J") Stainless Steel — Industrial Use Horizontal Enclosures for Bulletins 512H and 513H

    Click to enlarge - 512H_513H_Dimensions


    Unilock Enclosures — Type 3R, 7 & 9, Class I (Enclosure Code "U") Groups C & D, Class II, Groups E, F & G — Divisions 1& 2 for Bulletins 505, 509, and 513

    Click to enlarge - 500Line-1_149-1    Click to enlarge - 500Line-1_149-2

    Note: For bolted enclosures Type 7 & 9 and Type 3R, 7, & 9 dimensions, consult factory.

    Bolted Enclosures — Type 7 & 9 and Type 3R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F, & G — Divisions 1 & 2 for Bulletin 505 Full Voltage Reversing Starters

    NEMA Sizes 0…1

    Click to enlarge - 1_133_1    Click to enlarge - 1_133_2

    NEMA Sizes 2…4

    Click to enlarge - 1_133_3    Click to enlarge - 1_133_4

    NEMA Size Approximate Dimensions in Inches (Millimeters)
    A Wide B High C Deep D E F G
    2 21
    (533.4)
    26-3/4
    (679.5)
    10-7/32
    (259.6)
    25-1/2
    (647.7)
    16-1/4
    (412.8)
    2-7/16
    (61.9)
    2-5/8
    (66.7)
    3
    4 21-3/8
    (542.9)
    32-5/8
    (828.7)
    11-7/16
    (290.5)
    31-3/8
    (796.9)
    16-1/4
    (412.8)
    2-13/16
    (71.4)
    3-1/2
    (88.9)
      

    Bolted Enclosures — Type 7 & 9 and Type 3R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G — Divisions 1 & 2 for Bulletin 509 Full Voltage Starters

    NEMA Sizes 0…2

    Click to enlarge - 1_134_1    Click to enlarge - 1_134_2

    NEMA Size Approximate Dimensions in Inches (Millimeters)
    A Wide B High C Deep D E
    0…1 8-3/4
    (222.2)
    15-1/16
    (382.6)
    8-13/18
    (208.8)
    14-3/16
    (360.4)
    5
    (127)
    2 8-7/8
    (225.4)
    18-5/16
    (465.1)
    8-13/16
    (208.8)
    17-7/16
    (442.9)
    5-3/8
    (136.5)
      

    NEMA Sizes 3…4

    Click to enlarge - 1_134_3    Click to enlarge - 1_133_4

    NEMA Size Approximate Dimensions in Inches (Millimeters)
    A Wide B High C Deep D E F G
    3 12-3/4
    (323.9)
    23-17/32
    (597.7)
    8-7/8
    (225.4)
    23-1/2
    (596.9)
    8
    (203.2)
    2-7/32
    (56.4)
    2-5/8
    (66.7)
    4 15-1/8
    (384.2)
    32-5/8
    (828.7)
    10-3/8
    (269.9)
    31-3/8
    (796.9)
    10
    (254)
    2-9/18
    (65.1)
    3-1/2
    (88.9)
      

    NEMA Size 5

    Click to enlarge - 1_134_4    Click to enlarge - 1_133_4

    Bolted Enclosures — Type 7 & 9 and Type 3R, 7 & 9, Class I, Groups C & D, Class II, Groups E, F & G — Divisions 1 & 2 for Bulletin 513 Full Voltage Combination Starters

    NEMA Sizes 0…2

    Click to enlarge - 1_135_1    Click to enlarge - 1_135_2

    NEMA Sizes 3…4

    Click to enlarge - 1_135_3


    NEMA Size Approximate Dimensions in Inches (Millimeters) Approx.
    Shipping
    Weight
    [lb (kg)]
    A Wide B High C Deep D E F G H J
    3 21
    (533.4)
    26-3/4
    (679.5)
    11-31/32
    (304.1)
    25-1/2
    (647.7)
    16-1/4
    (412.8)
    2-7/8
    (73)
    4-13/16
    (122.2)
    2-7/16
    (61.9)
    2-5/8
    (66.7)
    200
    (90)
    4 21-3/8
    (542.9)
    32-5/8
    (828.7)
    13-3/16
    (335)
    31-3/8
    (796.9)
    16-1/4
    (412.8)
    2-11/16
    (68.3)
    5-1/4
    (133.4)
    2-13/16
    (71.4)
    3-1/2
    (88.9)
    275
    (123.8)
      

    NEMA Size 5

    Click to enlarge - 1_135_4

    Renewal Parts

    Bulletin 500 Line of Contactors and Starters (excluding Modular Kits)

    Click to enlarge - NEMA-1_117-1    Click to enlarge - NEMA-1_118-1    Click to enlarge - 500Line-1_105-2
    Used on Size 00, Series B    Used on Size 00, Series D    Used on Size 0…5

    AC Operating Coils
    Voltage [V] Frequency [Hz] Size 00 Size 0…1
    Size 15/20…30 A
    Size 2
    Size 60 A
    Series B Series D 2-…3-Pole★ ‡  4-Pole★ 
    4-…5-Pole‡ 
    2-Pole★ 
    2-…3-Pole‡ 
    3-…4-Pole★ 
    4-…5-Pole‡ 
    Part. No.
    24 50 GA407 TA407
    60 GA013 TA013 CB013 CC013 CC013C
    110
    120
    50
    60
    GA473§  TA473 CB236 CC236 CC236C
    200…208 60 GA049 TA049 CB249 CC249 CC249C
    220
    240
    50
    60
    GA474♣  TA474♣  CB254 CC254 CC254C
    277 60 GA060 TA480 CB260 CC260 CC260C
    380 50 GA454 TA071 CB354 CB354C CC354 CC354C
    415 50 GA457 TA457 CB357 CB357C CC357 CC357C
    440
    480
    50
    60
    GA475 TA475 CB273 CC273 CC273C
    550 50 TA476 CB278 CC278 CC278C
    600 60 GA476
    Voltage [V] Frequency [Hz] Size 3
    Size 100 A
    Size 4
    Size 200 A
    Size 5
    Size 300 A
    2-Pole★ 
    2-…3-Pole‡ 
    3-…4-Pole★ 
    4-…5-Pole‡ 
    2-Pole★ 
    2-…3-Pole‡ 
    3-…4-Pole★ 
    4-…5-Pole‡ 
    Series L
    Part. No.
    24 60 CD013 CD013C
    110
    120
    50
    60
    CD236 CD236C CE236 CE236C AF236
    200…208 60 CD249 CD249C CE249 CE249C AF249
    220
    240