Bulletin 502L Combination Lighting Contactors
Bulletin 502L Combination Lighting Contactors
Catalog Number Explanation
Catalog Number Explanation
The information below is for reference purposes. Not all combinations will produce a valid cat. no. Refer to the tables on the following pages for product selection.
Example Cat. No.
| 502L
|
|
A
|
|
A
|
|
CD
|
|
24R
|
|
90
|
|
1
|
| a
|
|
b
|
|
c
|
|
d
|
|
e
|
|
f
|
| a
|
| Bulletin No.
|
| Bulletin No.
|
Description
|
| 502L
|
Combination lighting contactor with disconnect switch
|
| 503L
|
Combination lighting contactor with circuit breaker
|
| b
|
| Lighting Contactor Size
|
| Code
|
Max. Continuous Ampere Rating [A]
|
| A
|
15…20
|
| B
|
30
|
| C
|
60
|
| D
|
100
|
| E
|
200
|
| F
|
300
|
| c
|
| Enclosure Type
|
| Code
|
Description
|
| A
|
Type 1: General purpose, painted metal enclosure with spring latch door fastener, external overload relay reset, and non-metallic handle
|
| F
|
Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with screw fasteners, and non-metallic handle
|
| J
|
Type 3R/4/12: Rainproof, watertight, dusttight, painted metal enclosure with door safety hardware, and metal handle
|
| C
|
Type 4/4X: Watertight corrosion-resistant stainless steel enclosure with screw fasteners, and a stainless steel handle
|
| d
|
| Coil Voltage
|
| Voltage Code
|
Description
|
Line Voltage [V]
|
Coil Voltage [V]
|
| H
|
Common control (without transformer)
|
208
|
208
|
| A
|
240
|
240
|
| B
|
480
|
480
|
| C
|
600
|
600
|
| H
|
Transformer control★
|
208
|
120
|
| A
|
240
|
120
|
| B
|
480
|
120
|
| C
|
600
|
120
|
| AD
|
Separate control (without transformer)
|
208
|
120
|
| 240
|
120
|
| CD
|
480
|
120
|
| 600
|
120
|
| e
|
| Fuse Clip
|
| Code
|
Rating
|
Type
|
| 24R
|
30
|
Class R
|
| 25R
|
60
|
Class R
|
| 26R
|
100
|
Class R
|
| 27R
|
200
|
Class R
|
| 28R
|
400
|
Class R
|
| 25J
|
60
|
Class J
|
| 26J
|
100
|
Class J
|
| 27J
|
200
|
Class J
|
★ Note
When selecting a factory-installed control circuit transformer use the Transformer Control Voltage Suffix Code to denote the transformer primary voltage. The transformer secondary voltage and starter coil will both be 120V AC by default. Example: Cat. No. 512-BAB-6P-24R will have a transformer with a 480V primary voltage, 120V secondary voltage, and a 120V starter coil voltage. If a starter coil voltage other than 120V is desired, a second Voltage Suffix Code must be added to denote the coil and transformer secondary voltage. Example: Cat. No. 512-BABJ-6P-24R will have a transformer with a 480V primary voltage, 24V secondary voltage, and a 24V starter coil voltage.