Catalogs > Industrial Controls Catalog > Lighting Control > Combination Lighting Contactors > Bulletin 502L Combination Lighting Contactors
Bulletin 502L Combination Lighting Contactors
| Introduction | Standards Compliance and Certifications | Catalog Number Explanation | Product Selection | Modifications for Combination Devices |
| Accessories | Specifications | Full Load Motor Currents | Approximate Dimensions | Renewal Parts |
| Build a Catalog Number |
| Tungsten Lamp Loads [A] (Maximum 480V Line 277V Load) |
Maximum Continuous Ampere Rating [A] |
Line Voltage [V] | Fuse Clip Rating Fuses not included. Select per NEC. |
Type 1 General Purpose |
Type 3R/4/12 Rainproof, Waterproof, Dusttight |
Type 3R/4/12 Rainproof, Waterproof, Dusttight (Door Safety Hardware) |
Type 4/4X Watertight Corrosion- Resistant Stainless Steel |
| Cat. No.★ | Cat. No.★ | Cat. No.★ | Cat. No.★ | ||||
| 15 | 20 | 208…240 | 30 Class R | 502L-AAÄ-24R | 502L-AFÄ-24R | 502L-AJÄ-24R | 502L-ACÄ-24R |
| 480…600 | 30 Class R | 502L-AAÄ-24R | 502L-AFÄ-24R | 502L-AJÄ-24R | 502L-ACÄ-24R | ||
| 30 | 30 | 208…240 | 30 Class R | 502L-BAÄ-24R | 502L-BFÄ-24R | 502L-BJÄ-24R | 502L-BCÄ-24R |
| 480…600 | 30 Class R | 502L-BAÄ-24R | 502L-BFÄ-24R | 502L-BJÄ-24R | 502L-BCÄ-24R | ||
| 208…240 | 60 Class R | 502L-BAÄ-25R | 502L-BFÄ-25R | 502L-BJÄ-25R | 502L-BCÄ-25R | ||
| 480…600 | 60 Class R | 502L-BAÄ-25R | 502L-BFÄ-25R | 502L-BJÄ-25R | 502L-BCÄ-25R | ||
| 60 | 60 | 480…600 | 30 Class R | 502L-CAÄ-24R | 502L-CFÄ-24R | 502L-CJÄ-24R | 502L-CCÄ-24R |
| 208…240 | 60 Class R | 502L-CAÄ-25R | 502L-CFÄ-25R | 502L-CJÄ-25R | 502L-CCÄ-25R | ||
| 480…600 | 60 Class R | 502L-CAÄ-25R | 502L-CFÄ-25R | 502L-CJÄ-25R | 502L-CCÄ-25R | ||
| 208…240 | 100 Class J | 502L-CAÄ-26J | 502L-CFÄ-26J | 502L-CJÄ-26J | 502L-CCÄ-26J | ||
| 480…600 | 100 Class J | 502L-CAÄ-26J | 502L-CFÄ-26J | 502L-CJÄ-26J | 502L-CCÄ-26J | ||
| 100 | 100 | 480…600 | 60 Class R | 502L-DAÄ-25R | 502L-DFÄ-25R | 502L-DJÄ-25R | 502L-DCÄ-25R |
| 208…240 | 100 Class R | 502L-DAÄ-26R | 502L-DFÄ-26R | 502L-DJÄ-26R | 502L-DCÄ-26R | ||
| 480…600 | 100 Class R | 502L-DAÄ-26R | 502L-DFÄ-26R | 502L-DJÄ-26R | 502L-DCÄ-26R | ||
| 208…240 | 200 Class J | 502L-DAÄ-27J | 502L-DFÄ-27J | 502L-DJÄ-27J | 502L-DCÄ-27J | ||
| 480…600 | 200 Class J | 502L-DAÄ-27J | 502L-DFÄ-27J | 502L-DJÄ-27J | 502L-DCÄ-27J | ||
| 200 | 200 | 480…600 | 100 Class R | 502L-EAÄ-26R | 502L-EFÄ-26R | 502L-EJÄ-26R | 502L-ECÄ-26R |
| 208…240 | 200 Class R | 502L-EAÄ-27R | 502L-EFÄ-27R | 502L-EJÄ-27R | 502L-ECÄ-27R | ||
| 480…600 | 200 Class R | 502L-EAÄ-27R | 502L-EFÄ-27R | 502L-EJÄ-27R | 502L-ECÄ-27R | ||
| 208…240 | 400 Class R | 502L-EAÄ-28R | 502L-EFÄ-28R | 502L-EJÄ-28R | 502L-ECÄ-28J | ||
| 480…600 | 400 Class R | 502L-EAÄ-28R | 502L-EFÄ-28R | 502L-EJÄ-28R | 502L-ECÄ-28J | ||
| 300 | 300 | 208…600 | 400 Class R | 502L-FAÄ-28R | 502L-FFÄ-28R | 502L-FJÄ-28R | 502L-FCÄ-28R |
Ä Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no.
Example: Cat. No. 502L-AAÄ-24R becomes Cat. No. 502L-AAB-24R. For other voltages, consult your local Allen‑Bradley distributor.
| [V] | 208 | 230…240 | 460…480 | 575…600 | ||
| Common Control | AC, 60 Hz |
H | A | B | C | |
| Transformer Control (See Configuration of a Basic Combination Starter Note) | ||||||
| 120V Separate Control (without transformer) | AD | AD | CD | CD | ||
★ Non-Fusible Disconnect Type
Cat. nos. listed above include a fusible disconnect switch with Class R or J fuse clips. To order a non-fusible disconnect switch, eliminate the fuse clip code
from the cat. no. Example: Cat. No. 502L-BFB-24R becomes Cat. No. 502L-BFB.
Class H fuse clips can be supplied. Example: Cat. No. 502L-AAÄ-24R becomes Cat. No. 502L-AAÄ-24. Class J fuse clips can be supplied. Example: Cat. No. 502L-AAÄ-24R becomes Cat. No. 502L-AAÄ-24J. Class HRC form II fuse clips can be supplied. Example: Cat. No. 502L-AAÄ-24R becomes Cat. No. 502L-AAÄ-24E.