Circuit Breakers 140M and 140-CMN

Catalogs > Essentials Catalog (Europe) > Power > Motor Protection Circuit Breakers > Circuit Breakers 140M and 140-CMN > Accessories 140M, 140-CMN

Accessories 140M, 140-CMN

Accessories 140M, 140-CMN Accessories 140M
Accessories 140M, 140-CMN

  Description Term. No. Click to enlarge - 100M-66-3 Click to enlarge - 100M-66-4 For Use With   Cat. No.
N.O. N.C.
Click to enlarge - 140M-14-6 Front-Mounted Auxiliary Contact
1-pole or 2-pole
No additional space required
-One only per MPCB
13-14 1 0 140M-C, D, F ¬  140M-C-AFA10
11-12 0 1 140M-C, D, F   140M-C-AFA01
Click to enlarge - 140M-14-8 13-14 1 1 140M-C, D, F ¬  140M-C-AFA11
21-22
13-14 2 0 140M-C, D, F   140M-C-AFA20
23-24
11-12 0 2 140M-C, D, F   140M-C-AFA02
21-22
Click to enlarge - 140M-14-13 Right Side-Mounted Auxiliary Contact
2-pole
Adds 9 mm to the width of the device
-Two per MPCB
33-34 2 0 140M-C, D, F   140M-C-ASA20
43-44
31-32 0 2 140M-C, D, F   140M-C-ASA02
41-42
33-34 1 1 140M-C, D, F ¬  140M-C-ASA11
41-42
Click to enlarge - 140M-16-4 Front-Mounted Auxiliary Contact
Internal
2-pole
-One per MPCB
13-14 2 0 140-CMN   140-CA20
23-24
11-12 0 2 140-CMN   140-CA02
21-22
13-14 1 1 140-CMN   140-CA11
21-22
Click to enlarge - 140M-14-8 Front-Mounted Trip Contact
2-pole
Indicates tripping of device
No additional space required
13-14 2 0 140M-C, D, F   140M-C-AFAR10A10
27-28
11-12 1 1 140M-C, D, F   140M-C-AFAR10A01
27-28
Click to enlarge - 140M-14-13 Right-Side Mounted Trip Contact
2-pole
Indicates tripping of Motor Protection Circuit Breaker
Adds 9 mm to the width of the circuit breaker
-One only per MPCB
-A right-side mounted auxiliary contact may be tandem mounted on top of this Trip Contact
57-58 2 0 140M-C, D, F   140M-C-ASAR10M10
67-68
57-58 1 1 140M-C, D, F   140M-C-ASAR10M01
65-66
55-56 1 1 140M-C, D, F   140M-C-ASAR01M10
67-68
55-56 0 2 140M-C, D, F   140M-C-ASAR01M01
65-66
77-78 1 1 140M-C, D, F   140M-C-ASAM11
65-66
Click to enlarge - 140M-16-10 Front-Mounted Trip-Indicating Auxiliary Contact
Internal
2-pole
-One per MPCB
37-38 2 0 140-CMN   140-CT10-10
43-44
35-36 0 2 140-CMN   140-CT01-01
41-42
35-36 1 1 140-CMN   140-CT01-10
43-44
37-38 1 1 140-CMN   140-CT10-01
41-42
  
¬ May be ordered in package quantities of 20. Add letter M to the end of the cat. no. (Example: 140M-C-AFA10M).

Description Trip Rating For Use With Cat. No.
Click to enlarge - 140M-17-1 Undervoltage Trip
Left-side mounted
Adds 18 mm to the width of the circuit breaker
Automatically trips MPCB/MCP when voltage falls below 35…70%
24V, 50 Hz 140M-C, D, F 140M-C-UXK
110V, 50 Hz 140M-C-UXC
220…230V, 50 Hz 140M-C-UXF
380…400V, 50 Hz 140M-C-UXN
480V, 60 Hz/415V, 50 Hz 140M-C-UXB
Undervoltage Trip
Left-side mounted
Two early make contacts integrated
Adds 18 mm to the width of the circuit breaker
Automatically trips MPCB/MCP when voltage falls below 35…70%
24V, 50 Hz 140M-C, D, F 140M-C-UCK
110V, 50 Hz 140M-C-UCC
220…230V, 50 Hz 140M-C-UCF
380…400V, 50 Hz 140M-C-UCN
480V, 60 Hz/415V, 50 Hz 140M-C-UCB
Shunt Trip
Left-side mounted
Adds 18 mm to the width of the circuit breaker
Trips motor protector when voltage is removed
24V, 50 Hz 140M-C, D, F 140M-C-SNK
110V, 50 Hz 140M-C-SNC
220…230V, 50 Hz 140M-C-SNF
380…400V, 50 Hz 140M-C-SNN
480V, 60 Hz/415V, 50 Hz 140M-C-SNB
Click to enlarge - 140M-17-4 Undervoltage Trip Unit
Internal, front-mounted
Integrated short-circuit trip indication
Automatically trips MPCB when voltage falls below 35…70%
24V, 50/60 Hz 140-CMN 140-CUV-KJ
110V, 50 Hz/120V, 60 Hz 140-CUV-D
220V, 50 Hz/240V, 60 Hz 140-CUV-A
Click to enlarge - 140M-17-6 Shunt Trip Unit
Internal, front-mounted
Integrated short-circuit trip indication
Provides remote tripping of the MPCB
24V, 50/60 Hz 140-CMN 140-CRT-KJ
110V, 50 Hz/120V, 60 Hz 140-CRT-D
220V, 50 Hz/240V, 60 Hz 140-CRT-A
Click to enlarge - 140M-18-9 IP65 Non-Metallic Enclosure
Knockouts for M20 and M25 fittings
Suitable for flexible cable with internal ground wire or conduit when externally grounded around the outside of the enclosure (no UL approval)
Black Handle 140M-C 198E-AYTG2
Red/Yellow Handle 140M-C 198E-AYTJ2
Click to enlarge - 140M-18-10 Terminal Cover
For covering of unused commoning link terminals
IP2X finger protection
140M-C,
140M-D
140M-C-WS
140M-F 140M-F-WS
Click to enlarge - 140M-18-11 Screw Adapter
For screw arrangement of a Motor Protection Circuit Breaker
Package quantity = 10 ¬ 
140M-C, D, F 140M-C-N45
  
¬ Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces.

Description For Use With Cat. No.
Click to enlarge - 140M-18-1 Anti-Tamper Shield
Provides protection against inadvertent adjustment of the current setting
Package quantity = 10 ¬ 
140M-C, D, F 140M-C-CA
Click to enlarge - 140M-18-2 Lockable Twist Knob
For one padlock 4…6 mm (1/4 in.) dia. shackle
Can be locked in OFF position
Black 140M-C, D, F 140M-C-KN
Red/Yellow 140M-C/-D 140M-C-KRY
Red/Yellow 140M-F 140M-F-KRY
Click to enlarge - 140M-18-3 Padlockable Operating Knob
Accepts 8 mm (5/16 in.) dia. padlock — up to three padlocks
Permits padlocking in the off position
Black 140-CMN 140-KN
Red/Yellow 140-KRY
Click to enlarge - 140M-18-4 Door Coupling Handle
For three padlocks 4…8 mm (5/16 in.) dia.
IP66 Protection/Type 1, 4, 4X, 12
Interlock override capability
Can be modified for locking in ON position
Ships with coupling — order extension shaft and legend plate separately
Mounting depth (adapter-door):
140-C: 105.5 mm ± 5 mm (4.5 in. ± 3/16 in.)
140-D: 114.5 mm ± 5 mm (4.5 in. ± 3/16 in.)
140-F: 137.1 mm ± 5 mm (5.4 in. ± 3/16 in.)
Black
140M-C, D, F
140M-C-DN66

140-CMN
140-CDN66
Click to enlarge - 140M-18-5 Red/Yellow
140M-C, D, F
140M-C-DRY66

140-CMN
140-CDRY66
Click to enlarge - 140M-18-6 Extension Shaft
Cut to required length for mounting depth (adapter-door):
140M-C: 117…338 mm (4.6.…13.3 in.)
140M-D: 126…347 mm (5.0.…13.7 in.)
140M-F: 149…369 mm (5.4.…14.5 in.)
140-CMN: 180…403 mm (7.1.…15.9 in.)
140M-C-DN66,
140M-C-DRY66,
140-CDN66,
140-CDRY66
140M-C-DS
140M-C: 117...488 mm (4,6...19,2 in.)
140M-D: 126...497 mm (5,0...19,6 in.)
140M-F: 149...519 mm (5,4...20,4 in.)
140-CMN: 180...553 mm (7,1...21,8 in.)
140M-C-DSL
Click to enlarge - 140M-18-7 Legend Plate
Marking: "Hauptschalter" and "Main Switch"
Marking: "Not-Aus" and "Emergency Off"
140-CDN66 140M-C-DFCN
140-CDRY66 140M-C-DFCRY
Click to enlarge - 140M-18-8 Locking Tag
Padlock attachment to the lockable handles
Up to three padlocks 4…8 mm (5/16 in.) dia. shackle
140M-C-KN
140M-C-KRY
140M-F-KRY
140M-C-M3
  
¬ Sold only in multiples of 10. Order (quantity of) 10 to receive one package of 10 pieces.