Description
|
Term. No.
|
|
|
For Use With
|
|
Cat. No.
|
| N.O.
|
N.C.
|
| Screw Terminals
|
|
Front-Mounted Auxiliary Contact 1-pole or 2-pole No additional space required Only 1 per device
|
13-14
|
1
|
0
|
140M-C, D, F; 140U-D (UL489 only in combination with 140M-C-AFC)
|
⋆
|
140M-C-AFA10
|
| 11-12
|
0
|
1
|
|
140M-C-AFA01
|
|
13-14, 21-22
|
1
|
1
|
⋆
|
140M-C-AFA11
|
13-14, 23-24
|
2
|
0
|
|
140M-C-AFA20
|
11-12, 21-22
|
0
|
2
|
|
140M-C-AFA02
|
|
Right Side-Mounted Auxiliary Contact 2-pole Adds 9 mm to the width of the device Two per MPCB
|
33-34, 43-44
|
2
|
0
|
140M-C, D, F
|
|
140M-C-ASA20
|
31-32, 41-42
|
0
|
2
|
|
140M-C-ASA02
|
33-34, 41-42
|
1
|
1
|
⋆
|
140M-C-ASA11
|
|
Front-Mounted Trip Contact 2-pole Indicates tripping of device No additional space required
|
13-14, 27-28
|
2
|
0
|
140M-C, D, F; 140U-D (UL489 only in combination with 140M-C-AFC)
|
|
140M-C-AFAR10A10
|
11-12, 27-28
|
1
|
1
|
|
140M-C-AFAR10A01
|
|
Right-Side Mounted Trip Contact 2-pole Indicates tripping of motor protection circuit breaker Adds 9 mm to the width of the circuit breaker One only per MPCB A right-side mounted auxiliary contact may be tandem mounted on top of this trip contact
|
57-58, 67-68
|
2
|
0
|
140M-C, D, F
|
|
140M-C-ASAR10M10
|
57-58, 65-66
|
1
|
1
|
|
140M-C-ASAR10M01
|
55-56, 67-68
|
1
|
1
|
|
140M-C-ASAR01M10
|
55-56, 65-66
|
0
|
2
|
|
140M-C-ASAR01M01
|
77-78, 65-66
|
1
|
1
|
|
140M-C-ASAM11
|
| Spring Clamp Terminals
|
|
Front-Mounted Auxiliary Contact 1-pole or 2-pole No additional space required - Only 1 per MPCB
|
13-14
|
1
|
0
|
140M-C, D, F; 140M-RC
|
|
140M-RC-AFA10
|
| 11-12
|
0
|
1
|
|
140M-RC-AFA01
|
Front-Mounted Auxiliary Contact 1-pole or 2-pole No additional space required
|
13-14, 21-22
|
1
|
1
|
140M-C, D, F; 140M-RC
|
|
140M-RC-AFA11
|
13-14, 23-24
|
2
|
0
|
|
140M-RC-AFA20
|
|
Front-Mounted Trip Contact 2-pole Indicates tripping of device No additional space required
|
13-14, 27-28
|
2
|
0
|
140M-C, D, F; 140M-RC
|
|
140M-RC-AFAR10A10
|
11-12, 27-28
|
1
|
1
|
|
140M-RC-AFAR10A01
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. (Example: 140M-C-AFA10M).
|
|
|
Description
|
Term. No.
|
|
|
For Use With
|
Cat. No.
|
| N.O.
|
N.C.
|
|
Front-Mounted Auxiliary Contact Internal 2-pole 1 per MPCB
|
13-14, 23-24
|
2
|
0
|
140-CMN
|
140-CA20
|
11-12, 21-22
|
0
|
2
|
140-CMN
|
140-CA02
|
13-14, 21-22
|
1
|
1
|
140-CMN
|
140-CA11
|
|
Front-Mounted Trip-Indicating Auxiliary Contact Internal 2-pole 1 per MPCB
|
37-38, 43-44
|
2
|
0
|
140-CMN
|
140-CT10-10
|
35-36, 41-42
|
0
|
2
|
140-CMN
|
140-CT01-01
|
35-36, 43-44
|
1
|
1
|
140-CMN
|
140-CT01-10
|
37-38, 41-42
|
1
|
1
|
140-CMN
|
140-CT10-01
|
|
|
| Description
|
Trip Rating
|
For Use With
|
Cat. No.
|
|
Undervoltage Trip Left-side mounted Adds 18 mm to the width of the circuit breaker Automatically trips MPCB/MCP when voltage falls below 35…70%
|
24V, 50 Hz
|
140M-C, D, F; 140U-D (trip unit series letter B and later)
|
140M-C-UXK
|
| 110V, 50 Hz
|
140M-C-UXC
|
| 220…230V, 50 Hz
|
140M-C-UXF
|
| 380…400V, 50 Hz
|
140M-C-UXN
|
| 480V, 60 Hz/415V, 50 Hz
|
140M-C-UXB
|
Undervoltage Trip Left-side mounted 2 early make contacts integrated Adds 18 mm to the width of the circuit breaker Automatically trips MPCB/MCP when voltage falls below 35…70%
|
24V, 50 Hz
|
140M-C, D, F; 140U-D (trip unit series letter B and later)
|
140M-C-UCK
|
| 110V, 50 Hz
|
140M-C-UCC
|
| 220…230V, 50 Hz
|
140M-C-UCF
|
| 380…400V, 50 Hz
|
140M-C-UCN
|
| 480V, 60 Hz/415V, 50 Hz
|
140M-C-UCB
|
Shunt Trip Left-side mounted Adds 18 mm to the width of the circuit breaker Trips motor protector when voltage is removed
|
24V, 50 Hz
|
140M-C, D, F; 140U-D
|
140M-C-SNK
|
| 110V, 50 Hz
|
140M-C-SNC
|
| 220…230V, 50 Hz
|
140M-C-SNF
|
| 380…400V, 50 Hz
|
140M-C-SNN
|
| 480V, 60 Hz/415V, 50 Hz
|
140M-C-SNB
|
|
Undervoltage Trip Unit Internal, front-mounted Integrated short-circuit trip indication Automatically trips MPCB when voltage falls below 35…70%
|
24V, 50/60 Hz
|
140-CMN
|
140-CUV-KJ
|
| 110V, 50 Hz/120V, 60 Hz
|
140-CUV-D
|
| 220V, 50 Hz/240V, 60 Hz
|
140-CUV-A
|
|
Shunt Trip Unit Internal, front-mounted Integrated short-circuit trip indication Provides remote tripping of the MPCB
|
24V, 50/60 Hz
|
140-CMN
|
140-CRT-KJ
|
| 110V, 50 Hz/120V, 60 Hz
|
140-CRT-D
|
| 220V, 50 Hz/240V, 60 Hz
|
140-CRT-A
|
|
Communication Module DeviceNet Starter Auxiliary DSA I/O for Distributed Starters. For complete product information, see catalog A117 or on-line catalog at www.ab.com
|
|
|
| Description
|
For Use With
|
Cat. No.
|
|
Anti-Tamper Shield Provides protection against inadvertent adjustment of the current setting
|
10 pcs/ pkg
|
140M-C, D, F
|
140M-C-CA
|
|
Lockable Twist Knob For one padlock 5 mm (3/16 in.) Æ shackle Can be locked in OFF position
|
Black
|
140M-C, D, F; 140U-D
|
140M-C-KN1
|
Red/ Yellow
|
140M-C-KRY1
|
|
Locking Tag Padlock attachment to the lockable handles Up to three padlocks 4…8 mm (5/16 in.) Æ shackle
|
140M-C-KN1, 140M-C-KRY1
|
140M-C-M3
|
|
Padlockable Operating Knob Accepts 8 mm (5/16 in.) Æ padlock shackle — up to three padlocks Permits padlocking in the off position
|
Black
|
140-CMN
|
140-KN
|
Red/ Yellow
|
140-KRY
|
|
Door Coupling Handle For 3 padlocks 4…8 mm (5/16 in.) in diameter IP66 Protection/Type 1, 4, 4X, 12 Interlock override capability Can be modified for locking in ON position Ships with coupling — order extension shaft and legend plate separately Mounting depth (front of DIN Rail to front of enclosure door): - 140M-C: 105.5 mm ± 5 mm (4.15 in. ± 3/16 in.) - 140M-D: 114.5 mm ± 5 mm (4.5 in. ± 3/16 in.) - 140M-F: 137.1 mm ± 5 mm (5.4 in. ± 3/16 in.) - 140-CMN: 169 mm +/- 5 mm (6.7 in. +/- 3/16 in.) - 140U-D: 114.5mm +/- 5mm (4.5 in. +/- 3/16 in.) ser E or later handles only
|
Black
|
140M-C, D, F; 140U-D
|
140M-C-DN66
|
| 140-CMN
|
140-CDN66
|
|
Red/ Yellow
|
140M-C, D, F; 140U-D
|
140M-C-DRY66
|
| 140-CMN
|
140-CDRY66
|
|
Legend Plate Marking: "Hauptschalter" and "Main Switch" Marking: "Not-Aus" and "Emergency Off"
|
140-CDN66
|
140M-C-DFCN
|
| 140-CDRY66
|
140M-C-DFCRY
|
|
Extension Shaft Cut to required length for mounting depth (front of DIN Rail to front of enclosure door): - 140M-C: 117…338 mm (4.6.…13.3 in.) - 140M-D: 126…347 mm (5.0.…13.7 in.) - 140M-F: 149…369 mm (5.9.…14.5 in.) - 140-CMN: 180…403 mm (7.1.…15.9 in.) - 140U-D: 126...347 mm (5.0...13.7 in.) ser E or later handles only
|
140M-C-DN66, 140M-C-DRY66, 140-CDN66, 140-CDRY66
|
140M-C-DS
|
Extension Shaft (Extended Length) Cut to required length for mounting depth (front of DIN Rail to front of enclosure door): - 140M-C: 117…488 mm (4.6…19.2 in.) - 140M-D: 126…497 mm (5.0…19.6 in.) - 140M-F: 149…519 mm (5.9…20.4 in.) - 140-CMN: 180…553 mm (7.1…21.8 in.) - 140U-D: 126...497 mm (5.0...19.6 in.) ser E or later handles only
|
140M-C-DSL
|
|
Coupler Included with Cat. Nos. 140M-C-DN66 and 140M-C-DRY66
|
140M-C, D, F; 140U-D
|
140M-C-DNC
|
|
|
| Description
|
For Use With
|
|
Cat. No.
|
|
IP65 Non-Metallic Enclosure Knockouts for M20 and M25 fittings Suitable for flexible cable with internal ground wire or conduit when externally grounded around the outside of the enclosure (no UL/CSA approval)
|
Black Handle
|
140M-C
|
|
198E-AYTG2
|
| Red/Yellow Handle
|
140M-C
|
|
198E-AYTJ2
|
|
Screw Adapter For screw arrangement of a motor protection circuit breaker Package quantity = 10
|
140M-C, D, F; 140U-D
|
|
140M-C-N45
|
|
ECO Connecting Module — 12 A For DOL and reversing starters Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M and 100-K contactors
|
140M-C to 100-K
|
⋆
|
140M-C-PEK12
|
ECO Connecting Modules — 25 A Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M MPCB and 100-C (with AC coils or 24V DC electronic coils) contactors
|
140M-C to 100-C09…C23
|
|
140M-C-PEC23
|
| 140M-D to 100-C09…C23
|
|
140M-D-PEC23
|
ECO Connecting Modules — 25 A Eco-starters mount on single DIN Rail (100-C on DIN Rail) Electrical and mechanical interconnection of 140M MPCB and 100-C (with AC or DC coils)
|
140M-C, 140M-D to 100-C09…C23
|
|
140M-C-PEC23A
|
Connecting Modules — 25 and 45 A Contactor and MPCB MUST BE mounted separately on (2) DIN Rails Electrical interconnection of 140M and 100-C (with AC coils)
|
140M-C to 100-C09…C23
|
|
140M-C-PNC23
|
| 140M-D to 100-C09…C23
|
|
140M-D-PNC23
|
| 140M-D to 100-C30…C37
|
|
140M-D-PNC37
|
| 140M-F to 100-C30…C37
|
|
140M-F-PNC37
|
| 140M-F to 100-C43
|
|
140M-F-PNC43
|
Flexible Connecting Module — 22 A (25 A) Flexible electrical interconnection Allows variable spacing between 140M MPCB and 100-C contactor (with AC or DC coils: 105…145 mm DIN Rail spacing with AC coils, 105…125 mm with DC coils)
|
140M-C, 140M-D to 100-C09…C43
|
§
|
140M-D-PFC23DM
|
Coil Modules — 25 A and 45 A For use with Bulletin 103T/107T 3-component starters
|
140M-C, -D to 100-C09…C23
|
|
140M-C-PSC23
|
| 140M-D, -F to 100-C30…C43
|
|
140M-F-PSC43
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. (Example: 140M-C-PEK12M).
|
| May be ordered in package quantities of 20. Add letter M to the end of the cat. no. (Example: 140M-C-PEC23M).
|
| § 140M-C / 140-D to 100-C30…C43 allowable Ith = 25 A for IEC applications.
|
| Description
|
For Use With
|
Cat. No.
|
|
Spacing Adapter Required for self-protected combination motor controller (Type E) applications of Bul. 140M-C, -D, and -F MPCBs. Not for use with bus bars.
|
140M-C, -D
|
140M-C-TE1
|
| 140M-F
|
140M-F-TE
|
|
Feeder Block for Compact Busbar Supply of compact busbars Increases terminal capacity
|
140M-C
|
140M-C-WBE
|
| 140M-F
|
140M-F-WBE
|
|
Feeder Terminal for Compact Busbar For supply of compact busbars Top feed — overlaps compact busbar Meets IEC spacing requirements
|
140M-C, -D
|
140M-C-WTN
|
|
Feeder Terminal for Compact Busbar For supply of compact busbars Top feed — overlaps compact busbar Meets UL Type E spacing requirements
|
140M-C, -D
|
140M-C-WTEN
|
| 140M-F
|
140M-F-WTE
|
|
Three-Phase Compact Busbar for 32 A Motor Protection Circuit Breakers — 64 A Max. Continuous Current 45 mm spacing For use with front-mounted auxiliary contact
|
2 connections
|
140M-C, -D
|
140M-C-W452N
|
| 3 connections
|
140M-C-W453N
|
| 4 connections
|
140M-C-W454N
|
| 5 connections
|
140M-C-W455N
|
|
Three-Phase Compact Busbar for 32 A Motor Protection Circuit Breakers — 64 A Max. Continuous Current 54 mm spacing For use with side-mounted auxiliary contact
|
2 connections
|
140M-C, -D
|
140M-C-W542N
|
| 3 connections
|
140M-C-W543N
|
| 4 connections
|
140M-C-W544N
|
| 5 connections
|
140M-C-W545N
|
|
Three-Phase Compact Busbar for 45 A Motor Protection Circuit Breakers — 115 A Max. Continuous Current 54 mm spacing For use with front-mounted auxiliary contact
|
2 connections
|
140M-F
|
140M-F-W542
|
| 3 connections
|
140M-F-W543
|
| 4 connections
|
140M-F-W544
|
Three-Phase Compact Busbar for 45 A Motor Protection Circuit Breakers — 115 A Max. Continuous Current 63 mm spacing For use with side-mounted auxiliary contact
|
2 connections
|
140M-F
|
140M-F-W632
|
| 3 connections
|
140M-F-W633
|
| 4 connections
|
140M-F-W634
|
|
Terminal Cover For covering of unused compact bus bar terminals IP2X finger protection Must be ordered in multiples of 10 (10 pcs/pkg)
|
140M-C, 140M-D
|
140M-C-WSN
|
| 140M-F
|
140M-F-WS
|
|
Top Hat Rail Adpapter — 10 mm Adjusts the depth of the 140M-C to the 140M-D Allows the use of compact busbars accross both frame sizes Must be ordered in multiples of 10 (10 pcs/pkg)
|
140M-C
|
140-KBH2
|
|
|