Circuit Breakers 140M and 140-CMN

Catalogs > Essential Components Catalog (Europe) > Power > Motor Protection Circuit Breakers > Circuit Breakers 140M and 140-CMN > Accessories 140M, 140-CMN

Accessories 140M, 140-CMN

Accessories 140M, 140-CMN Accessories 140M
Accessories 140M

Description For Use With   Cat. No.
Click to enlarge - 140M-18-9 IP65 Non-Metallic Enclosure
  • Knockouts for M20 and M25 fittings

  • Suitable for flexible cable with internal ground wire or conduit when externally grounded around the outside of the enclosure (no UL/CSA approval)
  • Black Handle 140M-C   198E-AYTG2
    Red/Yellow Handle 140M-C   198E-AYTJ2
    Click to enlarge - 140M-18-11 Screw Adapter
  • For screw arrangement of a motor protection circuit breaker

  • Package quantity = 10
  • 140M-C, D, F; 140U-D   140M-C-N45
    Click to enlarge - 140M-19-1 ECO Connecting Module — 12 A
  • For DOL and reversing starters

  • Eco-starters mount on single DIN Rail (140M on DIN Rail)

  • Electrical and mechanical interconnection of 140M and 100-K contactors
  • 140M-C to 100-K ⋆  140M-C-PEK12
    ECO Connecting Modules — 25 A
  • Eco-starters mount on single DIN Rail (140M on DIN Rail)

  • Electrical and mechanical interconnection of 140M MPCB and 100-C (with AC coils or 24V DC electronic coils) contactors
  • 140M-C to 100-C09…C23 ‡  140M-C-PEC23
    140M-D to 100-C09…C23 ‡  140M-D-PEC23
    ECO Connecting Modules — 25 A
  • Eco-starters mount on single DIN Rail (100-C on DIN Rail)

  • Electrical and mechanical interconnection of 140M MPCB and 100-C (with AC or DC coils)
  • 140M-C, 140M-D to 100-C09…C23 ‡  140M-C-PEC23A
    Connecting Modules — 25 and 45 A
  • Contactor and MPCB MUST BE mounted separately on (2) DIN Rails

  • Electrical interconnection of 140M and 100-C (with AC coils)
  • 140M-C to 100-C09…C23   140M-C-PNC23
    140M-D to 100-C09…C23   140M-D-PNC23
    140M-D to 100-C30…C37   140M-D-PNC37
    140M-F to 100-C30…C37   140M-F-PNC37
    140M-F to 100-C43   140M-F-PNC43
    Flexible Connecting Module — 22 A (25 A)
  • Flexible electrical interconnection

  • Allows variable spacing between 140M MPCB and 100-C contactor (with AC or DC coils: 105…145 mm DIN Rail spacing with AC coils, 105…125 mm with DC coils)
  • 140M-C, 140M-D to 100-C09…C43 §  140M-D-PFC23DM
    Coil Modules — 25 A and 45 A
  • For use with Bulletin 103T/107T 3-component starters
  • 140M-C, -D to 100-C09…C23   140M-C-PSC23
    140M-D, -F to 100-C30…C43   140M-F-PSC43
      
    ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. (Example: 140M-C-PEK12M).
    ‡ May be ordered in package quantities of 20. Add letter M to the end of the cat. no. (Example: 140M-C-PEC23M).
    § 140M-C / 140-D to 100-C30…C43 allowable Ith = 25 A for IEC applications.

    Description For Use With Cat. No.
    Click to enlarge - 140M-19-2 Spacing Adapter
  • Required for self-protected combination motor controller (Type E) applications of Bul. 140M-C, -D, and -F MPCBs. Not for use with bus bars.
  • 140M-C, -D 140M-C-TE1
    140M-F 140M-F-TE
    Click to enlarge - 140M-C-WBE_L Feeder Block for Compact Busbar
  • Supply of compact busbars

  • Increases terminal capacity
  • 140M-C 140M-C-WBE
    140M-F 140M-F-WBE
    Click to enlarge - 140M-C-WTN_L Feeder Terminal for Compact Busbar
  • For supply of compact busbars

  • Top feed — overlaps compact busbar

  • Meets IEC spacing requirements
  • 140M-C, -D 140M-C-WTN
    Click to enlarge - 140M-C-WTEN_L Feeder Terminal for Compact Busbar
  • For supply of compact busbars

  • Top feed — overlaps compact busbar

  • Meets UL Type E spacing requirements
  • 140M-C, -D 140M-C-WTEN
    140M-F 140M-F-WTE
    Click to enlarge - 140M-C-W453N_L Three-Phase Compact Busbar for 32 A Motor Protection Circuit Breakers — 64 A Max. Continuous Current
  • 45 mm spacing

  • For use with front-mounted auxiliary contact
  • 2 connections 140M-C, -D 140M-C-W452N
    3 connections 140M-C-W453N
    4 connections 140M-C-W454N
    5 connections 140M-C-W455N
    Click to enlarge - 140M-C-W543N_L Three-Phase Compact Busbar for 32 A Motor Protection Circuit Breakers — 64 A Max. Continuous Current
  • 54 mm spacing

  • For use with side-mounted auxiliary contact
  • 2 connections 140M-C, -D 140M-C-W542N
    3 connections 140M-C-W543N
    4 connections 140M-C-W544N
    5 connections 140M-C-W545N
    Click to enlarge - 140M-19-6 Three-Phase Compact Busbar for 45 A Motor Protection Circuit Breakers — 115 A Max. Continuous Current
  • 54 mm spacing

  • For use with front-mounted auxiliary contact
  • 2 connections 140M-F 140M-F-W542
    3 connections 140M-F-W543
    4 connections 140M-F-W544
    Three-Phase Compact Busbar for 45 A Motor Protection Circuit Breakers — 115 A Max. Continuous Current
  • 63 mm spacing

  • For use with side-mounted auxiliary contact
  • 2 connections 140M-F 140M-F-W632
    3 connections 140M-F-W633
    4 connections 140M-F-W634
    Click to enlarge - 140M-C-WSN_L Terminal Cover
  • For covering of unused compact bus bar terminals

  • IP2X finger protection

  • Must be ordered in multiples of 10
  • (10 pcs/pkg)
    140M-C,
    140M-D
    140M-C-WSN
    140M-F 140M-F-WS
    Click to enlarge - 140M-KBH2_L Top Hat Rail Adpapter — 10 mm
  • Adjusts the depth of the 140M-C to the 140M-D

  • Allows the use of compact busbars accross both frame sizes

  • Must be ordered in multiples of 10
  • (10 pcs/pkg)
    140M-C 140-KBH2