Accessories for 100-C, 100S-C

Auxiliary Contacts

Auxiliary Contacts (For 100-C09…C97 contactors) ⋆ 

  Description Click to enlarge - 100M-66-3 Click to enlarge - 100M-66-4 For Use With Standard
Auxiliary
Contact
Bifurcated
Auxiliary
Contact
N.O. N.C. Cat. No. ‡  Cat. No. ‡ 
Screw Terminals
Click to enlarge - 100-C_104-C-86-3 Auxiliary Contact Blocks for Front Mounting
  • 2- and 4-pole

  • Quick and easy mounting without tools

  • Electronically-compatible contacts down to 17V, 5 mA

  • Mechanically linked performance between N.O. and N.C. poles and to the main contactor poles (except for L types)

  • Models with equal function with several terminal numbering choices

  • 1L = Late break N.C./early make N.O.

  • Bifurcated versions for switchingdown to 5V, 3 mA also available
  • § 
    0 2 100-C all 100-FA02 100-FAB02
    C30Ä00…C97Ä00 100-FB02 100-FBB02
    1 1 100-C all 100-FA11 100-FAB11
    C30Ä00…C97Ä00 100-FB11 100-FBB11
    C09Ä10…C23Ä10 100-FC11 100-FCB11
    2 0 100-C all 100-FA20 100-FAB20
    C30Ä00…C97Ä00 100-FB20 100-FBB20
    Click to enlarge - 100-C_104-C-86-4 0 4 100-C all 100-FA04 100-FAB04
    1 3 100-C all 100-FA13 100-FAB13
    2 2 100-C all 100-FA22 100-FAB22
    C30Ä00…C97Ä00 100-FB22 100-FBB22
    C09Ä10…C23Ä10 100-FC22 100-FCB22
    3 1 100-C all 100-FA31 100-FAB31
    C09Ä10…C23Ä10 100-FC31 100-FCB31
    4 0 100-C all 100-FA40 100-FAB40
    1+1L 1+1L 100-C all 100-FAL22
    Spring Clamp Terminals
    Click to enlarge - 100-CRFA20 Product Shot Auxiliary Contact Blocks for Front Mounting
  • 2- and 4-pole

  • Quick and easy mounting without tools

  • Electronic-compatible contacts down to 17V, 5 mA

  • Mechanically linked performance between N.O. and N.C. poles and to the main contactor poles (except for L types)

  • Models with equal function with several terminal numbering choices

  • 1L = Late break N.C./early make N.O.
  • 0 2 100-CR, 700-CRF 100-CRFA02
    1 1 100-CRFA11
    100-CRFB11
    100-CRFC11
    2 0 100-CRFA20
    1L 1L 100-CRFBL11
    Click to enlarge - 100-CRFB22 Product Shot 2 2 100-CR, 700-CRF 100-CRFA22
    100-CRFC22
    100-CRFB22
    3 1 100-CRFA31
    4 0 100-CRFA40
    1+1L 1+1L 100-CRFAL22
      
    ⋆ Max. number of auxiliary contacts that may be mounted:
        AC coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side,
        4 N.C. front or side, 6 total.
        DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side,
        4 N.C. front or side, 4 total.
    ‡ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-SB01M).

      Description Click to enlarge - 100M-66-3 Click to enlarge - 100M-66-4 For Use With Cat. No. ‡ 
    N.O. N.C.
    Click to enlarge - 100-C_104-C-86-11 Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations
  • 1- and 2-pole

  • Two-way numbering for right or left mounting on the contactor

  • Quick and easy mounting without tools

  • Electronic-compatible contacts down to 17V, 10 mA

  • Mirror contact performance to the main contactor poles

  • 1L = Late break N.C./early make N.O.
  • 0 1 100-C 100-SB01
    1 0 100-C §  100-SB10
    0 2 100-C §  100-SB02
    1 1 100-C §  100-SB11
    2 0 100-C §  100-SB20
    1L 1L 100-C §  100-SBL11
      
    ⋆ Max. number of auxiliary contacts that may be mounted:
        AC coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side,
        4 N.C. front or side, 6 total.
        DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side,
        4 N.C. front or side, 4 total.
    ‡ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-SB01M).
    § Double numbering — Left-side mounting only is recommended for cat. no. 100-C09…100-C23 due to double numbering.

    Control Modules (For 100-C09…C97 contactors)

      Description Voltage Range For Use With Cat. No.
    Click to enlarge - 100-C_104-C-87-11 Mechanical Interlocks
  • For interlocking of two contactors.

  • Common interlock for all Bul. 100-C contactor sizes

  • Interlocking of different sizes possible

  • Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts

  • 9 mm dovetail connector included

  • Mechanical only,
    without auxiliary contacts
    100-C (except 100-C40, -C90) 100-MCA00
    Mechanical/ electrical interlock with 2 N.C. auxiliary contacts 100-MCA02
    Click to enlarge - 100-C_104-C-87-15 Mechanical Latch
  • Following contactor latching, the contactor coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66).

  • Electrical or manual release

  • 1 N.O. + 1 N.C. auxiliary contacts

  • Suitable for all Bul. 100-C contactor sizes, 9…97 A
  • Maximum command duration 0.03…10 s 100-C with AC or 24V DC electronic coils (except 100-C90) 100-FL11Ä
      

    Ä Voltage Suffix Code for Mechanical Latch

    The cat. no. as listed is incomplete. Select a voltage suffix code from the table below to complete the cat. no. Example: 230V, 50/60 Hz: Cat. no. 100-FL11Ä becomes cat. no. 100-FL11KF.

    AC Control   AC Control   AC Control
    Code Description Code Description Code Description
    KJ 24V 50/60 Hz KD 110V 50/60 Hz KN 400V 50/60 Hz
    KY 48V 50/60 Hz KF 230V 50/60 Hz    
      
    For other AC voltages visit our website or consult your local sales office.

      Description For Use With Cat. No.
    Click to enlarge - 100-C_104-C-87-1 Pneumatic Timing Modules
  • Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
  • On-Delay  
    0.3…30 s Range
    100-C or 700-CF with AC coils or DC electronic coils   
    100-FPTA30
    2…180 s Range 100-FPTA180
    Off-Delay  
    0.3…30 s Range
    100-C all, 700-CF all   
    100-FPTB30
    2…180 s Range 100-FPTB180
    Click to enlarge - 100-C_104-C-87-4 Electronic Timing Modules — On-Delay
    Delay of the contactor or control relay solenoid.
    The contactor or control relay is energized at the end of the delay time.
    On-Delay  
    0.1…3 s Range
    100-C or 700-CF with
    110…240V,
    50/60 Hz or
    110…250V DC coils
      
    100-ETA3
    1…30 s Range 100-ETA30
    10…180 s Range 100-ETA180
      
    110…240V, 50/60 Hz
    110…250V DC
     
    On-Delay 100-C or 700-CF with 24…48V DC coils   
    0.1…3 s Range 100-ETAZJ3
    1…30 s Range 100-ETAZJ30
    10…180 s Range 100-ETAZJ180
      
    24…48V DC
     
    Click to enlarge - 100-C_104-C-87-7 Electronic Timing Modules — Off-Delay
    Delay of the contactor or control relay solenoid.
    After interruption of the control signal, the contactor or control relay is de-energized at the end of the delay time.
    Off-Delay 100-C or 700-CF with 110…240V 50/60 Hz coils   
    0.3…3 s Range 100-ETB3
    1…30 s Range 100-ETB30
    10…180 s Range 100-ETB180
      
    110…240V,
    50/60 Hz
     
    Off-Delay 100-C09…C37 or 700-CF with 24V 50/60 Hz coils   
    0.3…3 s Range 100-ETBKJ3
    1…30 s Range 100-ETBKJ30
    10…180 s Range 100-ETBKJ180
      
    24V, 50/60 Hz
     
    Click to enlarge - 100-C_104-C-87-9 Electronic Timing Modules
  • Delay of the contactor solenoid. Contactor K 3 (Y) is de-energized (off) and K 2 (D) is energized (on) after the end of the set Y end time. (Switching delay at 50 ms.)

  • Continuous adjustment range

  • High repeat accuracy
  • Transition Time Y Contactor
    1…30 s Range  

    110…240V, 50/60 Hz
    100-C with 110…240V, 50/60 Hz coils 100-ETY30
    Click to enlarge - 700-FSY_bw Electronic Star-Delta Timing Relay
    Output Y picks up when the supply voltage is applied and resets again after time t. After a fixed changeover time tu, output relay D picks up and remains energized until the supply voltage is interrupted.
  • 22.5 mm width

  • 24…48V DC,
    24…240V AC, 50/60 Hz
    100-K, 100-C,
    100-D
      
    700-FSY2DU23
      
  • 22.5 mm width

  • 346…440V AC, 50/60 Hz
    700-FSY2DA40
  • 17.5 mm width

  • 24…48V DC
    24…240V AC. 50/60 Hz
    100-K, 100-C,
    100-D
    700-FEY2QU23
      

      Description Voltage Range For Use With   Cat. No.
    Click to enlarge - 100-C_104-C-88-1 DC Interface (Electronic)
  • Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor.

  • Requires no additional surge suppression on the relay coils
  • Input: 12V DC
    Output: 110…240V AC
    100-C with AC coils 110…240V AC   100-JE12
    Input: 18…30V DC
    Output: 110…240V AC
      100-JE
    Input: 48V DC
    Output: 110…240V AC
      100-JE48
    Screw Terminals
    Click to enlarge - 100-C_104-C-88-3 Surge Suppressors
  • For limitation of coil switching transients.

  • Plug-in, coil mounted.

  • Suitable for 100-C contactor sizes, 9…97 A.

  • RC, varistor and diode Versions.
  • RC Module AC Operating Mechanism
    24…48V AC, 50/60 Hz 100-C with AC coils ⋆  100-FSC48
    110…280V AC, 50/60 Hz ⋆  100-FSC280
    380…480V AC, 50/60 Hz ⋆  100-FSC480
    Varistor Module AC/DC Operating Mechanism
    12…55V AC/ 12…77V DC 100-C with AC coils or 100-C09…-C43 with DC coils ⋆  100-FSV55
    56…136V AC/ 78…180V DC ⋆  100-FSV136
    137…277V AC/ 181…350V DC ⋆  100-FSV277
    278…575V AC ⋆  100-FSV575
    Diode Module DC Operating Mechanism
    12…250V DC 100-C09…-C43 with DC coils ‡  ⋆  100-FSD250
    Spring Clamp Terminals
    Click to enlarge - 100-CRFS_Product Shot Surge Suppressors
  • For limitation of coil switching transients.

  • Plug-in, coil mounted.

  • Suitable for 100-C contactor sizes, 9…97 A.

  • RC, varistor and diode Versions.
  • RC Module AC Operating Mechanism
    24…48V AC, 50/60 Hz 100-CR, 700-CRF ⋆  100-CRFSC48
    110…280V AC, 50/60 Hz ⋆  100-CRFSC280
    380…480V AC, 50/60 Hz ⋆  100-CRFSC480
    Varistor Module AC/DC Operating Mechanism
    12…55V AC/ 12…77V DC 100-CR, 700-CRF ⋆  100-CRFSV55
    56…136V AC/ 78…180V DC ⋆  100-CRFSV136
    137…277V AC/ 181…350V DC ⋆  100-CRFSV277
    278…575V AC ⋆  100-CRFSV575
    Diode Module DC Operating Mechanism
    12…250V DC 100-CR, 700-CRF ‡  ⋆  100-CRFSD250
      
    ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-FSC48M.
    ‡ Not for use with 100-CxxE…

    Star-Delta Starter Kits

    Power wiring kits were designed to aid in the field assembly of open-transition star-delta and reversing starters that use Bulletin 100-C contactors. These kits include line, load (and start-point) connections.

    Click to enlarge - 100-C_104-C-89-1
    170-PW23


    3-Phase Rating (50 Hz) Use with Cat. No. 100-... Cat. No.
    230V 380/415V 500V 690V Delta Star
    [kW] 1M 2M 1S
    5.5 8 8 8 C09 C09 C09 170-PW23
    7.5 11 11 11 C12 C12 C09
    10 14 15 14 C16 C16 C12
    14 21 21 19 C23 C23 C12
    18 28 28 28 C30 C30 C16 170-PW37
    19 35 35 32 C37 C37 C23
    23 40 40 41 C43 C43 C30 170-PW43
    33 58 60 56 C60 C60 C37 170-PW72
    39 69 67 70 C72 C72 C43
    47 82 82 81 C85 C85 C60 170-PW85
    50 90 90 90 C97 C97 C72
      

    Reversing Starter Kits

      Description For Use With Cat. No.
    Click to enlarge - 100-C_104-C-88-10 Reversing Power Wiring Kits
  • For reversing connection with a solid-state or thermal overload relay
  • 100-C09…C23 105-PW23
    100-C30…C37 105-PW37
    100-C43 105-PW43
    100-C60…C97 105-PW85
      

    Marking Systems

      Description PQ Cat. No.
    Click to enlarge - 100-C_104-C-89-2 Label Sheet
    105 self-adhesive paper labels each, 6 x 17 mm
    10 100-FMS
    Click to enlarge - 100-C_104-C-89-3 Marking Tag Sheet
    160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
    10 100-FMP
    Transparent Cover
    To be used with marking tag sheets
    100 100-FMC
    Click to enlarge - 1492-M7X12a_bw Snap-In Marker Card
    6 x 12 mm (120 markers/card)
    For mini-contactors, circuit breakers 140M-C, -D, -F
    5 1492-M6X12
    10 x 17 mm (40 markers/card)
    For contactors, mini-contactors, circuit breakers
    5 1492-MS10X17
      
    PQ = Package Quantity

    Plastic Enclosures for DOL Starters

      Description For Use With Cat. No.
    Click to enlarge - 198E_A0S4_4c Plastic Enclosures for DOL Starters
    For Bulletin 100-C09…C23 contactors with overload relays Bulletin 193-ED, -EE or -T1
    Protection class IP66
    Prestampings for two pilot lights
       
    Material: ABS V-0 With blue RESET push button 100-C09…C23 + 193-ED, -EE, -CT 198E-A0S1
    With green START and raised red STOP/RESET push buttons, START contact kit included. 198E-A0S4
    Material: PC V-0 With blue RESET push button 100-C09…C23 + 193-ED, -EE, -CT 198E-C0S1
    With green START and raised red STOP/RESET push buttons, START contact kit included. 198E-C0S4
    Click to enlarge - 198E_PLA_4c Pushbutton Latch
    For maintained contact control, enclosures with START/STOP push buttons.
    198E-A0S4, 198E-C0S4 198E-PLA
    Click to enlarge - 198E_PNT_4c Neutral Terminal 198E-A…, 198E-C… 198E-PNT
    Click to enlarge - 198E-PCK_4c START Contact Kit
    Included in the enclosure, as spare part only.
    198E-A0S4, 198E-C0S4 198E-PCK
      Pilot Lights, see 140A Pilot Lights with Integrated LED Modules (Screw Terminal Connections)
      

    Plastic Enclosures for DOL or Reversing Starters

    Description For Use With Cat. No.
    Click to enlarge - 198E-C0S4R_Cover with holes Enclosure for DOL Starters with Electronic Overload Relay
    Installation of 193-E* extension modules possible.
    Operating units and starter components sold separately.
    Enclosure with Cutouts for Start - Stop and Reset Operators
    Neutral, Ground (PE) terminal and socket for contact blocks included.
    100-C09…C23 + 193-ED, -EE, -CT 198E-C2S4
    Enclosure for Reversing Starters with Electronic Overload Relay
    Also suitable for DOL Starters. Installation of 193-E* extension modules possible.
    Operating units and starter components sold separately.
    Enclosure with Cutouts for Start - Stop and Reset Operators
    Ground (PE) terminal and socket for Contact Blocks included.
    100-C09…C23 + 193-ED, -EE, -CT 198E-C0S4R
    Enclosure for DOL or Reversing Starters with Motor Protection Circuit Breaker
    Operating units and starter components sold separately.
    Enclosure with Cutouts for Start - Stop Operator and Circuit Breaker Operating Handle
    Ground (PE) terminal and socket for Contact Blocks included.
    140M-C, 140M-D + 100-C09…-C23 198E-C0C4R
    ECO Connecting Module — 25 A
    Electrical and mechanical connection between 140M and 100-C
    140M-C, 140M-D to 100-C09…C23 140M-C-PEC23A