Description
|
|
|
For Use With
|
Standard Auxiliary Contact
|
Bifurcated Auxiliary Contact
|
| N.O.
|
N.C.
|
Cat. No.
|
Cat. No.
|
| Screw Terminals
|
|
Auxiliary Contact Blocks for Front Mounting 2- and 4-pole Quick and easy mounting without tools Electronically-compatible contacts down to 17V, 5 mA Mechanically linked performance between N.O. and N.C. poles and to the main contactor poles (except for L types) Models with equal function with several terminal numbering choices 1L = Late break N.C./early make N.O. Bifurcated versions for switchingdown to 5V, 3 mA also available §
|
0
|
2
|
100-C all
|
100-FA02
|
100-FAB02
|
| C30Ä00…C97Ä00
|
100-FB02
|
100-FBB02
|
| 1
|
1
|
100-C all
|
100-FA11
|
100-FAB11
|
| C30Ä00…C97Ä00
|
100-FB11
|
100-FBB11
|
| C09Ä10…C23Ä10
|
100-FC11
|
100-FCB11
|
| 2
|
0
|
100-C all
|
100-FA20
|
100-FAB20
|
| C30Ä00…C97Ä00
|
100-FB20
|
100-FBB20
|
|
0
|
4
|
100-C all
|
100-FA04
|
100-FAB04
|
| 1
|
3
|
100-C all
|
100-FA13
|
100-FAB13
|
| 2
|
2
|
100-C all
|
100-FA22
|
100-FAB22
|
| C30Ä00…C97Ä00
|
100-FB22
|
100-FBB22
|
| C09Ä10…C23Ä10
|
100-FC22
|
100-FCB22
|
| 3
|
1
|
100-C all
|
100-FA31
|
100-FAB31
|
| C09Ä10…C23Ä10
|
100-FC31
|
100-FCB31
|
| 4
|
0
|
100-C all
|
100-FA40
|
100-FAB40
|
| 1+1L
|
1+1L
|
100-C all
|
100-FAL22
|
—
|
| Spring Clamp Terminals
|
|
Auxiliary Contact Blocks for Front Mounting 2- and 4-pole Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 5 mA Mechanically linked performance between N.O. and N.C. poles and to the main contactor poles (except for L types) Models with equal function with several terminal numbering choices 1L = Late break N.C./early make N.O.
|
0
|
2
|
100-CR, 700-CRF
|
100-CRFA02
|
—
|
| 1
|
1
|
100-CRFA11
|
—
|
| 100-CRFB11
|
—
|
| 100-CRFC11
|
—
|
| 2
|
0
|
100-CRFA20
|
—
|
| 1L
|
1L
|
100-CRFBL11
|
—
|
|
2
|
2
|
100-CR, 700-CRF
|
100-CRFA22
|
—
|
| 100-CRFC22
|
—
|
| 100-CRFB22
|
—
|
| 3
|
1
|
100-CRFA31
|
—
|
| 4
|
0
|
100-CRFA40
|
—
|
| 1+1L
|
1+1L
|
100-CRFAL22
|
—
|
|
|
⋆ Max. number of auxiliary contacts that may be mounted: AC coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side, 4 N.C. front or side, 6 total. DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side, 4 N.C. front or side, 4 total.
|
| May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-SB01M).
|
|
|
Description
|
|
|
For Use With
|
Cat. No.
|
| N.O.
|
N.C.
|
|
Auxiliary Contact Blocks for Side Mounting with Sequence Terminal Designations 1- and 2-pole Two-way numbering for right or left mounting on the contactor Quick and easy mounting without tools Electronic-compatible contacts down to 17V, 10 mA Mirror contact performance to the main contactor poles 1L = Late break N.C./early make N.O.
|
0
|
1
|
100-C
|
100-SB01
|
| 1
|
0
|
100-C §
|
100-SB10
|
| 0
|
2
|
100-C §
|
100-SB02
|
| 1
|
1
|
100-C §
|
100-SB11
|
| 2
|
0
|
100-C §
|
100-SB20
|
| 1L
|
1L
|
100-C §
|
100-SBL11
|
|
|
⋆ Max. number of auxiliary contacts that may be mounted: AC coil contactors — max. 4 N.O. contacts on the front of the contactor, 2 N.O. contacts on the side, 4 N.C. front or side, 6 total. DC coil contactors — max. 4 N.O. contacts on the front of the contactor or max 2 N.O. contacts on the side, 4 N.C. front or side, 4 total.
|
| May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-SB01M).
|
| § Double numbering — Left-side mounting only is recommended for cat. no. 100-C09…100-C23 due to double numbering.
|
|
|
Description
|
Voltage Range
|
For Use With
|
Cat. No.
|
|
Mechanical Interlocks For interlocking of two contactors. Common interlock for all Bul. 100-C contactor sizes Interlocking of different sizes possible Mechanical and electrical interlocking possible in one module by means of integrated auxiliary contacts 9 mm dovetail connector included
|
Mechanical only, without auxiliary contacts
|
100-C (except 100-C40, -C90)
|
100-MCA00
|
| Mechanical/ electrical interlock with 2 N.C. auxiliary contacts
|
100-MCA02
|
|
Mechanical Latch Following contactor latching, the contactor coil is immediately de-energized (off) by the N.C. auxiliary contact (65-66). Electrical or manual release 1 N.O. + 1 N.C. auxiliary contacts Suitable for all Bul. 100-C contactor sizes, 9…97 A
|
Maximum command duration 0.03…10 s
|
100-C with AC or 24V DC electronic coils (except 100-C90)
|
100-FL11Ä
|
|
|
| AC Control
|
|
AC Control
|
|
AC Control
|
| Code
|
Description
|
Code
|
Description
|
Code
|
Description
|
| KJ
|
24V 50/60 Hz
|
KD
|
110V 50/60 Hz
|
KN
|
400V 50/60 Hz
|
| KY
|
48V 50/60 Hz
|
KF
|
230V 50/60 Hz
|
|
|
|
|
| For other AC voltages visit our website or consult your local sales office.
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Pneumatic Timing Modules Pneumatic timing element contacts switch after the delay time. The contacts on the main control relay continue to operate without delay.
|
On-Delay 0.3…30 s Range
|
100-C or 700-CF with AC coils or DC electronic coils
|
100-FPTA30
|
| 2…180 s Range
|
100-FPTA180
|
Off-Delay 0.3…30 s Range
|
100-C all, 700-CF all
|
100-FPTB30
|
| 2…180 s Range
|
100-FPTB180
|
|
Electronic Timing Modules — On-Delay Delay of the contactor or control relay solenoid. The contactor or control relay is energized at the end of the delay time.
|
On-Delay 0.1…3 s Range
|
100-C or 700-CF with 110…240V, 50/60 Hz or 110…250V DC coils
|
100-ETA3
|
| 1…30 s Range
|
100-ETA30
|
| 10…180 s Range
|
100-ETA180
|
110…240V, 50/60 Hz 110…250V DC
|
|
| On-Delay
|
100-C or 700-CF with 24…48V DC coils
|
|
| 0.1…3 s Range
|
100-ETAZJ3
|
| 1…30 s Range
|
100-ETAZJ30
|
| 10…180 s Range
|
100-ETAZJ180
|
24…48V DC
|
|
|
Electronic Timing Modules — Off-Delay Delay of the contactor or control relay solenoid. After interruption of the control signal, the contactor or control relay is de-energized at the end of the delay time.
|
Off-Delay
|
100-C or 700-CF with 110…240V 50/60 Hz coils
|
|
| 0.3…3 s Range
|
100-ETB3
|
| 1…30 s Range
|
100-ETB30
|
| 10…180 s Range
|
100-ETB180
|
110…240V, 50/60 Hz
|
|
| Off-Delay
|
100-C09…C37 or 700-CF with 24V 50/60 Hz coils
|
|
| 0.3…3 s Range
|
100-ETBKJ3
|
| 1…30 s Range
|
100-ETBKJ30
|
| 10…180 s Range
|
100-ETBKJ180
|
24V, 50/60 Hz
|
|
|
Electronic Timing Modules Delay of the contactor solenoid. Contactor K 3 (Y) is de-energized (off) and K 2 (D) is energized (on) after the end of the set Y end time. (Switching delay at 50 ms.) Continuous adjustment range High repeat accuracy
|
Transition Time Y Contactor 1…30 s Range
110…240V, 50/60 Hz
|
100-C with 110…240V, 50/60 Hz coils
|
100-ETY30
|
|
Electronic Star-Delta Timing Relay Output Y picks up when the supply voltage is applied and resets again after time t. After a fixed changeover time tu, output relay D picks up and remains energized until the supply voltage is interrupted.
|
22.5 mm width 24…48V DC, 24…240V AC, 50/60 Hz
|
100-K, 100-C, 100-D
|
700-FSY2DU23
|
22.5 mm width 346…440V AC, 50/60 Hz
|
700-FSY2DA40
|
17.5 mm width 24…48V DC 24…240V AC. 50/60 Hz
|
100-K, 100-C, 100-D
|
700-FEY2QU23
|
|
|
|
|
Description
|
Voltage Range
|
For Use With
|
|
Cat. No.
|
|
DC Interface (Electronic) Interface between the DC control signal (PLC) and the AC operating mechanism of the contactor. Requires no additional surge suppression on the relay coils
|
Input: 12V DC Output: 110…240V AC
|
100-C with AC coils 110…240V AC
|
|
100-JE12
|
Input: 18…30V DC Output: 110…240V AC
|
|
100-JE
|
Input: 48V DC Output: 110…240V AC
|
|
100-JE48
|
| Screw Terminals
|
|
Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted. Suitable for 100-C contactor sizes, 9…97 A. RC, varistor and diode Versions.
|
RC Module AC Operating Mechanism
|
| 24…48V AC, 50/60 Hz
|
100-C with AC coils
|
⋆
|
100-FSC48
|
| 110…280V AC, 50/60 Hz
|
⋆
|
100-FSC280
|
| 380…480V AC, 50/60 Hz
|
⋆
|
100-FSC480
|
| Varistor Module AC/DC Operating Mechanism
|
| 12…55V AC/ 12…77V DC
|
100-C with AC coils or 100-C09…-C43 with DC coils
|
⋆
|
100-FSV55
|
| 56…136V AC/ 78…180V DC
|
⋆
|
100-FSV136
|
| 137…277V AC/ 181…350V DC
|
⋆
|
100-FSV277
|
| 278…575V AC
|
⋆
|
100-FSV575
|
| Diode Module DC Operating Mechanism
|
| 12…250V DC
|
100-C09…-C43 with DC coils
|
⋆
|
100-FSD250
|
| Spring Clamp Terminals
|
|
Surge Suppressors For limitation of coil switching transients. Plug-in, coil mounted. Suitable for 100-C contactor sizes, 9…97 A. RC, varistor and diode Versions.
|
RC Module AC Operating Mechanism
|
| 24…48V AC, 50/60 Hz
|
100-CR, 700-CRF
|
⋆
|
100-CRFSC48
|
| 110…280V AC, 50/60 Hz
|
⋆
|
100-CRFSC280
|
| 380…480V AC, 50/60 Hz
|
⋆
|
100-CRFSC480
|
| Varistor Module AC/DC Operating Mechanism
|
| 12…55V AC/ 12…77V DC
|
100-CR, 700-CRF
|
⋆
|
100-CRFSV55
|
| 56…136V AC/ 78…180V DC
|
⋆
|
100-CRFSV136
|
| 137…277V AC/ 181…350V DC
|
⋆
|
100-CRFSV277
|
| 278…575V AC
|
⋆
|
100-CRFSV575
|
| Diode Module DC Operating Mechanism
|
| 12…250V DC
|
100-CR, 700-CRF
|
⋆
|
100-CRFSD250
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-FSC48M.
|
| Not for use with 100-CxxE…
|
| 3-Phase Rating (50 Hz)
|
Use with Cat. No. 100-...
|
Cat. No.
|
| 230V
|
380/415V
|
500V
|
690V
|
Delta
|
Star
|
| [kW]
|
1M
|
2M
|
1S
|
| 5.5
|
8
|
8
|
8
|
C09
|
C09
|
C09
|
170-PW23
|
| 7.5
|
11
|
11
|
11
|
C12
|
C12
|
C09
|
| 10
|
14
|
15
|
14
|
C16
|
C16
|
C12
|
| 14
|
21
|
21
|
19
|
C23
|
C23
|
C12
|
| 18
|
28
|
28
|
28
|
C30
|
C30
|
C16
|
170-PW37
|
| 19
|
35
|
35
|
32
|
C37
|
C37
|
C23
|
| 23
|
40
|
40
|
41
|
C43
|
C43
|
C30
|
170-PW43
|
| 33
|
58
|
60
|
56
|
C60
|
C60
|
C37
|
170-PW72
|
| 39
|
69
|
67
|
70
|
C72
|
C72
|
C43
|
| 47
|
82
|
82
|
81
|
C85
|
C85
|
C60
|
170-PW85
|
| 50
|
90
|
90
|
90
|
C97
|
C97
|
C72
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Reversing Power Wiring Kits For reversing connection with a solid-state or thermal overload relay
|
100-C09…C23
|
105-PW23
|
| 100-C30…C37
|
105-PW37
|
| 100-C43
|
105-PW43
|
| 100-C60…C97
|
105-PW85
|
|
|
|
|
Description
|
PQ
|
Cat. No.
|
|
Label Sheet 105 self-adhesive paper labels each, 6 x 17 mm
|
10
|
100-FMS
|
|
Marking Tag Sheet 160 perforated paper labels each, 6 x 17 mm, to be used with a transparent cover
|
10
|
100-FMP
|
Transparent Cover To be used with marking tag sheets
|
100
|
100-FMC
|
|
Snap-In Marker Card
|
6 x 12 mm (120 markers/card) For mini-contactors, circuit breakers 140M-C, -D, -F
|
5
|
1492-M6X12
|
10 x 17 mm (40 markers/card) For contactors, mini-contactors, circuit breakers
|
5
|
1492-MS10X17
|
|
|
| PQ = Package Quantity
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Plastic Enclosures for DOL Starters For Bulletin 100-C09…C23 contactors with overload relays Bulletin 193-ED, -EE or -T1 Protection class IP66 Prestampings for two pilot lights
|
|
|
| Material: ABS V-0
|
With blue RESET push button
|
100-C09…C23 + 193-ED, -EE, -CT
|
198E-A0S1
|
| With green START and raised red STOP/RESET push buttons, START contact kit included.
|
198E-A0S4
|
| Material: PC V-0
|
With blue RESET push button
|
100-C09…C23 + 193-ED, -EE, -CT
|
198E-C0S1
|
| With green START and raised red STOP/RESET push buttons, START contact kit included.
|
198E-C0S4
|
|
Pushbutton Latch For maintained contact control, enclosures with START/STOP push buttons.
|
198E-A0S4, 198E-C0S4
|
198E-PLA
|
|
Neutral Terminal
|
198E-A…, 198E-C…
|
198E-PNT
|
|
START Contact Kit Included in the enclosure, as spare part only.
|
198E-A0S4, 198E-C0S4
|
198E-PCK
|
|
|
Pilot Lights, see 140A Pilot Lights with Integrated LED Modules (Screw Terminal Connections)
|
|
|
| Description
|
For Use With
|
Cat. No.
|
|
Enclosure for DOL Starters with Electronic Overload Relay Installation of 193-E* extension modules possible. Operating units and starter components sold separately.
|
Enclosure with Cutouts for Start - Stop and Reset Operators Neutral, Ground (PE) terminal and socket for contact blocks included.
|
100-C09…C23 + 193-ED, -EE, -CT
|
198E-C2S4
|
Enclosure for Reversing Starters with Electronic Overload Relay Also suitable for DOL Starters. Installation of 193-E* extension modules possible. Operating units and starter components sold separately.
|
Enclosure with Cutouts for Start - Stop and Reset Operators Ground (PE) terminal and socket for Contact Blocks included.
|
100-C09…C23 + 193-ED, -EE, -CT
|
198E-C0S4R
|
Enclosure for DOL or Reversing Starters with Motor Protection Circuit Breaker Operating units and starter components sold separately.
|
Enclosure with Cutouts for Start - Stop Operator and Circuit Breaker Operating Handle Ground (PE) terminal and socket for Contact Blocks included.
|
140M-C, 140M-D + 100-C09…-C23
|
198E-C0C4R
|
ECO Connecting Module — 25 A Electrical and mechanical connection between 140M and 100-C
|
140M-C, 140M-D to 100-C09…C23
|
140M-C-PEC23A
|
|
|