| Rated Operational Current (Ie) [A]
|
Ratings for Switching AC Motors — AC-2, AC-3, AC-4
|
Auxiliary Contacts
|
|
Standard Auxiliary Contact
|
Bifurcated Auxiliary Contact
|
| 60 °C
|
40 °C
|
3Æ kW (50 Hz)
|
|
|
| AC-3
|
AC-1
|
400/415V
|
N.O.
|
N.C. ⋆
|
Cat. No.
|
Cat. No.
|
| 3-Pole AC-Operated Contactors
|
| 115
|
250
|
63
|
2
|
2
|
|
100S-D115Ä22C
|
100S-D115Ä22BC
|
| 140
|
250
|
78
|
2
|
2
|
|
100S-D140Ä22C
|
100S-D140Ä22BC
|
| 180
|
250
|
101
|
2
|
2
|
|
100S-D180Ä22C
|
100S-D180Ä22BC
|
| 210
|
350
|
118
|
2
|
2
|
|
100S-D210Ä22C
|
100S-D210Ä22BC
|
| 250
|
350
|
140
|
2
|
2
|
|
100S-D250Ä22C
|
100S-D250Ä22BC
|
| 300
|
450
|
170
|
2
|
2
|
|
100S-D300Ä22C
|
100S-D300Ä22BC
|
| 420
|
540
|
238
|
2
|
2
|
|
100S-D420Ä22C
|
100S-D420Ä22BC
|
| 630
|
800
|
355
|
2
|
2
|
|
100S-D630Ä22C
|
100S-D630Ä22BC
|
| 860
|
1000
|
500
|
2
|
2
|
|
100S-D860Ä22C
|
100S-D860Ä22BC
|
| 3-Pole DC-Operated Contactors
|
| 115
|
250
|
63
|
3
|
2/1L
|
|
100S-D115Ä33LC
|
—
|
| 2
|
2
|
|
100S-D115Ä22C
|
100S-D115Ä22BC
|
| 140
|
250
|
78
|
3
|
2/1L
|
|
100S-D140Ä33LC
|
—
|
| 2
|
2
|
|
100S-D140Ä22C
|
100S-D140Ä22BC
|
| 180
|
250
|
101
|
3
|
2/1L
|
|
100S-D180Ä33LC
|
—
|
| 2
|
2
|
|
100S-D180Ä22C
|
100S-D180Ä22BC
|
| 210
|
350
|
118
|
2
|
2
|
|
100S-D210Ä22C
|
100S-D210Ä22BC
|
| 250
|
350
|
140
|
2
|
2
|
|
100S-D250Ä22C
|
100S-D250Ä22BC
|
| 300
|
450
|
170
|
2
|
2
|
|
100S-D300Ä22C
|
100S-D300Ä22BC
|
| 420
|
540
|
238
|
2
|
2
|
|
100S-D420Ä22C
|
100S-D420Ä22BC
|
| 630
|
800
|
355
|
2
|
2
|
|
100S-D630Ä22C
|
100S-D630Ä22BC
|
| 860
|
1000
|
500
|
2
|
2
|
|
100S-D860Ä22C
|
100S-D860Ä22BC
|
|
|
| ⋆ The N.C. contacts meet IEC 60947-4 Annex F requirements to mirror contact performance. The N.C. mirror contacts are wired in series or parallel and must be used as monitoring contacts with feedback to the safety circuit.
|
| Conventional Coil: The pickup winding must be interconnected with the N.C. late-breaking auxiliary contact.
|
| Electronic Coil w/ EI Interface ⋆
|
[V]
|
24
|
42-64
|
110-130
|
208-277
|
380-415
|
440-480
|
380-500
|
| -D115…-D300
|
50/60 Hz
|
EJ
|
EY
|
ED
|
EA
|
—
|
—
|
EN
|
| -D420
|
50/60 Hz
|
—
|
—
|
ED
|
EA
|
—
|
—
|
EN
|
| -D630…-D860
|
50/60 Hz
|
—
|
—
|
ED
|
EA
|
EN
|
EB
|
—
|
|
|
| Electronic Coil w/ EI Interface ⋆
|
[V]
|
24
|
48-72
|
110-130
|
200-255
|
| -D115…-D300
|
DC
|
EZJ
|
EZY
|
EZD
|
EZA
|
| -D420
|
DC
|
—
|
—
|
EZD
|
EZA
|
| -D630…-D860
|
DC
|
—
|
—
|
ED
|
EA
|
|
|
⋆ Signal voltage of the electronic interface (100-D…, 100S-D…): nominal Ue: 24V DC/Ie: 15 mA Pickup voltage: 13.0V DC…30.2V DC Dropout Voltage: 3.0V DC…+5.0V DC.
|
| Not available with 100(S)-D300
|
| § For conventional DC coils, the pickup winding must be interconnected with the N.C. late-breaking auxiliary contact(s).
|