Description
|
|
|
For Use With
|
Auxiliary Contact
|
| Standard
|
Bifurcated
|
| N.O.
|
N.C.
|
Cat. No.
|
Cat. No.
|
|
Auxiliary Contacts Side-mounted With IEC sequence terminal designations Standard contacts 17V/10 mA Bifurcated contacts for signals down to 5V/2 mA
|
1
|
1
|
100-D left or right inside mounting
|
100-DS1-11
|
100-DS1-B11H
|
| 1
|
1
|
100-D left or right outside mounting
|
100-DS2-11
|
100-DS2-B11H
|
| 1
|
1L
|
100-D left or right inside mounting
|
100-DS1-L11
|
100-DS1-BL11H
|
| 2
|
0
|
100-DS1-20
|
100-DS1-B20H
|
| 2
|
0
|
100-D left or right outside mounting
|
100-DS2-20
|
100-DS2-B20H
|
Auxiliary Contacts Electronic-compatible auxiliary contacts Ideal for use when switching low-power control circuits With IEC sequence terminal designations Contact ratings: AC-12, 250V, 0.1 A AC-15, DC-13, 3...125V, 1...100 mA
|
1
|
1
|
100-D left or right inside mounting
|
100-DS1-B11
|
—
|
|
|
|
|
Description
|
Suppressor Rating
|
For Use With
|
Cat. No.
|
|
Suppressor Module for Bul. 100-D Contactors For limiting surge voltage when coil circuits are interrupted Supplied as standard on all conventional DC coil contactors and all electronic coil contactors (as part of the supply module or delivered with separate suppressor module)
|
RC Module (AC control) for contactors with conventional coil 21...48V, 50 Hz; 24...55V, 60 Hz
|
100-D115...100-D180
|
100-DFSC48
|
| 95...110V, 50 Hz; 110...127V, 60 Hz
|
100-DFSC110
|
| 180...277V, 50 Hz; 208...277V, 60 Hz
|
100-DFSC240
|
| 380...550V, 50 Hz; 440...600V, 60 Hz
|
100-DFSC550
|
Varistor Module for contactors with conventional coil 55V AC
|
100-D115...100-D420
|
100-DFSV55
|
| 56...136V AC
|
100-DFSV136
|
| 137...277V AC
|
100-DFSV277
|
| 278...600V AC
|
100-DFSV575
|
| 208...277V AC ⋆
|
100-D115...100-D420
|
100-DFSV550
|
|
|
| ⋆ For overvoltage category IV (IEC 947 for 100-D...-EI) e.g., lightning protection requirements.
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Interlock — Mechanical Only No additional space required
|
100-D115…100-D420
|
100-DMA00
|
|
Interlock — Dual Electrical/Mechanical No additional space required Two N.C. auxiliary contacts
|
100-D115…100-D860
|
100-DMD02
|
Interlock — Dual Electrical/Mechanical Provides interlocking between Bul. 100-C and Bul. 100-D contactors Two N.C. auxiliary contacts
|
100-C60…100-C97 between 100-D115…100-D180
|
100-DMC02
|
|
Terminal Lugs Set of two Protection class IP2X per IEC 60529 and DIN 40 050
|
100-D115
|
100-DTB110
|
| 100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F
|
100-DTB180
|
| 100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G
|
100-DTB420
|
|
Control Circuit Terminal 2 x 2.5 mm2
|
Connects to Cat. Nos. 100-D115...D180
|
100-DAT1
|
| Connects to Cat. Nos. 100-D210...D420
|
100-DAT2
|
|
Phase Barriers Set of 4
|
100-D630…D860, 193-EC_H, 193-EE_H
|
100-DPB860
|
|
|
|
|
Description
|
Cross- section
|
For Use With
|
Terminal Connection
|
Cat. No.
|
100-D 115…180
|
100-D 210…420
|
100-D 630…860
|
|
Reversing: Input Connection Wye-Delta: Main-Delta connection
|
50 mm2
|
X
|
|
|
Terminal Blocks 100-DTB… Lugs, 100-DL…
|
100-D180-VLTB
|
| 120 mm2
|
|
X
|
|
100-D420-VLTB
|
| 350 mm2
|
|
|
X
|
Lugs, 100-DL…
|
100-D860-VL
|
|
Reversing: Output Connection Wye-Delta: Delta-Wye connection
|
50 mm2
|
X
|
|
|
Lugs, 100-DL…
|
100-D180-VT
|
| 120 mm2
|
|
X
|
|
100-D420-VT
|
| 350 mm2
|
|
|
X
|
100-D860-VT
|
|
50 mm2
|
X
|
|
|
Terminal Blocks 100-DTB…
|
100-D180-VLTB
|
|
Reversing: Input Connection Wye-Delta: Main-Delta connection
|
80 mm2
|
|
X
|
|
100-D420-VLTB
|
|
Wye-Delta: Neutral bridge
|
—
|
X
|
|
|
—
|
100-D180-VYU
|
| —
|
|
X
|
|
—
|
100-D420-VYU
|
| —
|
|
|
X
|
—
|
100-D860-VYU
|
|
Power Wiring Kits (for contactors using 100-DL lug kits)
|
For 100-D115…D180
|
Reversing
|
100-DPW180
|
| Two-speed, or changeover
|
100-D180-VLTB
|
| Wye-Delta/Star-Delta
|
100-DPY180
|
| For 100-D210…D420
|
Reversing
|
100-DPW420
|
| Two-speed, or changeover
|
100-D420-VLTB
|
| Wye-Delta/Star-Delta
|
100-DPY420
|
| For 100-D630…D860
|
Reversing
|
100-DPW860
|
| Two-speed, or changeover
|
100-D860-VL
|
|
Terminal Shields Set of two Protection class IP10 per IEC 60529 and DIN 40 050 For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
|
100-D115…100-D180, 193-FE
|
100-DTS180
|
| 100-D210...100-D420, 193-FE
|
100-DTS420
|
|
Terminal Covers Protection class IP20 per IEC 60529 and DIN 40 050 For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
|
100-D115…100-D180, 193-EC_F, 193-EE_F
|
100-DTC180
|
| 100-D210...100-D420, 193-EC_G, 193-EE_G
|
100-DTC420
|
| 100-D630…100-D860, 193-EC_H, 193-EE_H
|
100-DTC860
|
|
|