Accessories for 100-D, 100S-D

  Description Click to enlarge - 100M-66-3 Click to enlarge - 100M-66-4 For Use With Auxiliary Contact
Standard Bifurcated
N.O. N.C. Cat. No. Cat. No.
Click to enlarge - 100-MCA00_GS Auxiliary Contacts
  • Side-mounted

  • With IEC sequence terminal designations

  • Standard contacts 17V/10 mA

  • Bifurcated contacts for signals down to 5V/2 mA
  • 1 1 100-D left or right inside mounting 100-DS1-11 100-DS1-B11H
    1 1 100-D left or right outside mounting 100-DS2-11 100-DS2-B11H
    1 1L 100-D left or right inside mounting 100-DS1-L11 100-DS1-BL11H
    2 0 100-DS1-20 100-DS1-B20H
    2 0 100-D left or right outside mounting 100-DS2-20 100-DS2-B20H
    Auxiliary Contacts
  • Electronic-compatible auxiliary contacts

  • Ideal for use when switching low-power control circuits

  • With IEC sequence terminal designations

  • Contact ratings:
    AC-12, 250V, 0.1 A
    AC-15, DC-13, 3...125V, 1...100 mA
  • 1 1 100-D left or right inside mounting 100-DS1-B11
      

      Description Suppressor Rating For Use With Cat. No.
    Click to enlarge - 100-DFSC48_GS Suppressor Module for Bul. 100-D Contactors
    •   For limiting surge voltage when coil circuits are interrupted
    •   Supplied as standard on all conventional DC coil contactors and all electronic coil contactors (as part of the supply module or delivered with separate suppressor module)
    RC Module (AC control)
    for contactors with conventional coil
    21...48V, 50 Hz; 24...55V, 60 Hz
    100-D115...100-D180



    100-DFSC48
    95...110V, 50 Hz; 110...127V, 60 Hz 100-DFSC110
    180...277V, 50 Hz; 208...277V, 60 Hz 100-DFSC240
    380...550V, 50 Hz; 440...600V, 60 Hz 100-DFSC550
    Varistor Module
    for contactors with conventional coil
    55V AC
    100-D115...100-D420


    100-DFSV55
    56...136V AC 100-DFSV136
    137...277V AC 100-DFSV277
    278...600V AC 100-DFSV575
    208...277V AC ⋆  100-D115...100-D420 100-DFSV550
      
    ⋆ For overvoltage category IV (IEC 947 for 100-D...-EI) e.g., lightning protection requirements.

      Description For Use With Cat. No.
    Click to enlarge - 100-DMA00_GS Interlock — Mechanical Only
  • No additional space required
  • 100-D115…100-D420 100-DMA00
    Click to enlarge - 100-DMD02 Interlock — Dual Electrical/Mechanical
  • No additional space required

  • Two N.C. auxiliary contacts
  • 100-D115…100-D860 100-DMD02
    Interlock — Dual Electrical/Mechanical
  • Provides interlocking between Bul. 100-C and Bul. 100-D contactors

  • Two N.C. auxiliary contacts
  • 100-C60…100-C97 between 100-D115…100-D180 100-DMC02
    Click to enlarge - 100-DTB_GS Terminal Lugs
  • Set of two

  • Protection class IP2X per IEC 60529 and DIN 40 050
  • 100-D115 100-DTB110
    100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F 100-DTB180
    100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G 100-DTB420
    Click to enlarge - 100D-93-3 Control Circuit Terminal
    2 x 2.5 mm2
    Connects to Cat. Nos. 100-D115...D180 100-DAT1
    Connects to Cat. Nos. 100-D210...D420 100-DAT2
    Click to enlarge - 100D-93-6 Phase Barriers
    Set of 4
    100-D630…D860, 193-EC_H, 193-EE_H 100-DPB860
      

      Description Cross-
    section
    For Use With Terminal
    Connection
    Cat. No.
    100-D
    115…180
    100-D
    210…420
    100-D
    630…860
    Click to enlarge - 100-D180-VLTB_L Reversing: Input Connection
    Wye-Delta: Main-Delta connection
    50 mm2 X     Terminal Blocks
    100-DTB…
    Lugs, 100-DL…
    100-D180-VLTB
    120 mm2   X   100-D420-VLTB
    350 mm2     X Lugs, 100-DL… 100-D860-VL
    Click to enlarge - 100-D180_VT Reversing: Output Connection
    Wye-Delta: Delta-Wye connection
    50 mm2 X     Lugs, 100-DL… 100-D180-VT
    120 mm2   X   100-D420-VT
    350 mm2     X 100-D860-VT
    Click to enlarge - 100-D180_VTTB 50 mm2 X     Terminal Blocks
    100-DTB…
    100-D180-VLTB
    Click to enlarge - 100-D420_VYTB Reversing: Input Connection
    Wye-Delta: Main-Delta connection
    80 mm2   X   100-D420-VLTB
    Click to enlarge - 100-D180_VYU Wye-Delta: Neutral bridge X     100-D180-VYU
      X   100-D420-VYU
        X 100-D860-VYU
    Click to enlarge - 100D_Acc_PowerWiringKits Power Wiring Kits (for contactors using 100-DL lug kits) For 100-D115…D180 Reversing 100-DPW180
    Two-speed, or changeover 100-D180-VLTB
    Wye-Delta/Star-Delta 100-DPY180
    For 100-D210…D420 Reversing 100-DPW420
    Two-speed, or changeover 100-D420-VLTB
    Wye-Delta/Star-Delta 100-DPY420
    For 100-D630…D860 Reversing 100-DPW860
    Two-speed, or changeover 100-D860-VL
    Click to enlarge - 100-DTS_GS Terminal Shields
  • Set of two

  • Protection class IP10 per IEC 60529 and DIN 40 050

  • For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
  • 100-D115…100-D180, 193-FE 100-DTS180
    100-D210...100-D420, 193-FE 100-DTS420
    Click to enlarge - 100D-93-5 Terminal Covers
  • Protection class IP20 per IEC 60529 and DIN 40 050

  • For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
  • 100-D115…100-D180, 193-EC_F, 193-EE_F 100-DTC180
    100-D210...100-D420, 193-EC_G, 193-EE_G 100-DTC420
    100-D630…100-D860, 193-EC_H, 193-EE_H 100-DTC860