| Rated Operational Current (Ie) [A]
|
Ratings for switching AC motors - AC-2, AC-3
|
Auxiliary Contacts
|
|
Cat. No.
|
| 3Æ kW (50 Hz)
|
|
|
| AC-3
|
AC-1
|
400/415V
|
N.O.
|
N.C.
|
| Screw Terminals
|
| 5
|
20
|
2.2
|
1
|
0
|
⋆
|
100-K05Ä10
|
| 0
|
1
|
⋆
|
100-K05Ä01
|
| 9
|
20
|
4
|
1
|
0
|
⋆
|
100-K09Ä10
|
| 0
|
1
|
⋆
|
100-K09Ä01
|
| 12
|
20
|
5.5
|
1
|
0
|
⋆
|
100-K12Ä10
|
| 0
|
1
|
⋆
|
100-K12Ä01
|
| Spring Clamp Terminals
|
| 5
|
10
|
2.2
|
1
|
0
|
⋆
|
100-KR05Ä10
|
| 0
|
1
|
⋆
|
100-KR05Ä01
|
| 9
|
10
|
4
|
1
|
0
|
⋆
|
100-KR09Ä10
|
| 0
|
1
|
⋆
|
100-KR09Ä01
|
|
|
| ⋆ May be ordered in package quantities of 20. Add letter M to the end of the cat. no. Example: 100-K05KF10M.
|
| Ä The Cat. No. as listed is incomplete. Select a standard Coil Voltage Code from the table below to complete the Cat. No. Example: 230V, 50/60 Hz: Cat. No. 100-K05Ä10 becomes Cat. No. 100-K05KF10.
|
| AC Control
|
|
DC Control
|
| Code
|
Description
|
Code
|
Description
|
| KJ
|
24V 50/60 Hz
|
ZJ
|
24V DC
|
| KY
|
48V 50/60 Hz
|
DJ
|
24V DC with integrated diode
|
| D
|
110V 50 Hz
|
ZD
|
110V DC
|
| KF
|
230V 50/60 Hz
|
ZA
|
220V DC
|
| KN
|
400V 50/60 Hz
|
|
|
|
|
| For other voltages visit our website or consult your local sales office.
|
|
|
Description
|
|
|
For Use With
|
|
Cat. No.
|
| N.O.
|
N.C.
|
| Screw Terminals
|
|
Front-Mounted Auxiliary Contacts Auxiliary contact blocks 2- and 4-pole versions Choice of contact configurations Snap on, no tools required Electronic-compatible bifurcated contacts for signals down to 15V/2 mA Mirror Contact performance per IEC 60947-4-1
|
0
|
2
|
100-K05…K12
|
⋆
|
100-KFC02
|
| 1
|
1
|
⋆
|
100-KFC11
|
| 2
|
0
|
⋆
|
100-KFC20
|
| 0
|
4
|
100-K05…K12
|
⋆
|
100-KFC04
|
| 1
|
3
|
⋆
|
100-KFC13
|
| 3
|
1
|
⋆
|
100-KFC31
|
| 2
|
2
|
⋆
|
100-KFC22
|
| 4
|
0
|
⋆
|
100-KFC40
|
| Spring Clamp Terminals
|
|
Front-Mounted Auxiliary Contacts Auxiliary contact blocks 2- and 4-pole versions Choice of contact configurations Snap on, no tools required Electronic-compatible bifurcated contacts for signals down to 15V/2 mA Mirror Contact performance per IEC 60947-4-1
|
0
|
2
|
100-K
|
⋆
|
100-KRFC02
|
| 1
|
1
|
100-K
|
⋆
|
100-KRFC11
|
| 2
|
0
|
100-K
|
⋆
|
100-KRFC20
|
| 0
|
4
|
100-K
|
⋆
|
100-KRFC04
|
| 1
|
3
|
100-K
|
⋆
|
100-KRFC13
|
| 3
|
1
|
100-K
|
⋆
|
100-KRFC31
|
| 2
|
2
|
100-K
|
⋆
|
100-KRFC22
|
| 4
|
0
|
100-K
|
⋆
|
100-KRFC40
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFC02M.
|
|
|
Description
|
For Use With
|
PQ
|
Cat. No.
|
|
Surge Suppressor Plug-in type Limits surge voltage on coil drop-off
|
RC Suppressor
|
| 24…48V AC
|
100/104-K/-KR, 700-K/-KR
|
⋆
|
100-KFSC50
|
| 110…280V AC
|
⋆
|
100-KFSC280
|
| 380…480V AC
|
⋆
|
100-KFSC480
|
| MOV Suppressor
|
| 12…55V AC, 12…77V DC
|
100/104-K/-KR, 700-K/-KR
|
⋆
|
100-KFSV55
|
| 56…136V AC, 78…180V DC
|
⋆
|
100-KFSV136
|
| 137…277V AC, 181…250V DC
|
⋆
|
100-KFSV277
|
| Diode Suppressor
|
| 12…250V DC
|
100/104-K/-KR, 700-K/-KR
|
⋆
|
100-KFSD250
|
|
Mechanical Interlock For interlocking of two adjacent contactors No added width to contactor assembly Front mount plug-in type Optional auxiliary contact blocks and suppressor modules mount onto the interlock
|
100/104-K/-KR, 700-K/-KR
|
|
100-KMCH
|
|
ECO Connecting Module — 12 A For DOL and reversing starters Eco-starters mount on single DIN Rail (140M on DIN Rail) Electrical and mechanical interconnection of 140M and 100-K contactors
|
Connects: 140M-C circuit breakers with 100-K contactors
|
140M-C to 100-K
|
1⋆
|
140M-C-PEK12
|
|
Power Wiring Kit For Reversing and Star/Delta combinations. Star-point bridge not included. Min. interruption time 50 ms
|
—
|
100-K
|
1
|
100-KPR
|
|
Feeder Terminal for Compact Bus Bars Max. current 34 A
|
Supply of compact bus bars
|
100-K
|
1
|
100-KWT
|
|
Three-Phase Compact Bus Bars Max. current 34 A
|
For 100-K, 5…12 A contactors 45 mm spacing (3 connections)
|
100-K
|
1
|
100-KW453
|
For 100-K, 5…12 A contactors 45 mm spacing (4 connections)
|
1
|
100-KW454
|
|
|
| ⋆ May be ordered in package quantities of 10. Add letter M to the end of the cat. no. Example: 100-KFSC50M.
|
| PQ = Package Quantity
|