Bimetallic Overload Relays 193-T1
Bimetallic Overload Relays 193-T1
|
- Overload protection trip class 10 / 10A
- Phase loss protection
- Ambient temperature compensation
- Auxiliary contacts (1 N.O. and 1 N.C.)
- Manual/automatic reset mode selectable
- Test function for auxiliary contacts
- Stop button
- Trip Indicator
- Optional remote reset solenoid and external reset accessories
| For Use With ⋆ | Setting Range [A] § |
Max. Back-up gL/gG fuse [A] 50 kA, 690V AC IEC/EN 60947-4-1 Coordination |
Cat. No. | |
| Type 1 | Type 2 | |||
| 100-C09…100-C23 | 0.1…0.16 | 50 | — | 193-T1AA16 |
| 0.16…0.25 | 50 | — | 193-T1AA25 | |
| 0.25…0.40 | 50 | 2 | 193-T1AA40 | |
| 0.35…0.50 | 50 | 2 | 193-T1AA50 | |
| 0.45…0.63 | 50 | 2 | 193-T1AA63 | |
| 0.55…0.80 | 50 | 4 | 193-T1AA80 | |
| 0.75…1.0 | 50 | 4 | 193-T1AB10 | |
| 0.90…1.3 | 50 | 6 | 193-T1AB13 | |
| 1.1…1.6 | 50 | 6 | 193-T1AB16 | |
| 1.4…2.0 | 50 | 10 | 193-T1AB20 | |
| 1.8…2.5 | 50 | 16 | 193-T1AB25 | |
| 2.3…3.2 | 50 | 16 | 193-T1AB32 | |
| 2.9…4.0 | 50 | 16 | 193-T1AB40 | |
| 3.5…4.8 | 50 | 16 | 193-T1AB48 | |
| 4.5…6.3 | 50 | 20 | 193-T1AB63 | |
| 5.5…7.5 | 50 | 25 | 193-T1AB75 | |
| 7.2…10 | 50 | 25 | 193-T1AC10 | |
| 9.0…12.5 | 50 | 35 | 193-T1AC12 | |
| 100-C12…100-C23 | 11.3…16 | 50 | 35 | 193-T1AC16 |
| 100-C16…100-C23 | 15…20 | 80 | 40 | 193-T1AC20 |
| 17.5…21.5 | 80 | 50 | 193-T1AC21 | |
| 100-C23 | 21…25 | 80 | 50 | 193-T1AC25 |
| 100-C30…100-C37 | 15…20 | 80 | 40 | 193-T1BC20 |
| 17.5…21.5 | 80 | 50 | 193-T1BC21 | |
| 21…25 | 80 | 50 | 193-T1BC25 | |
| 24.5…30 | 100 | 63 | 193-T1BC30 | |
| 29…36 | 125 | 63 | 193-T1BC36 | |
| 100-C37 | 33…38 | 125 | 63 | 193-T1BC38 |
| 100-C43 | 17…25 | 100 | 50 | 193-T1CC25 |
| 24.5…36 | 125 | 80 | 193-T1CC36 | |
| 35…47 | 160 | 100 | 193-T1CC47 | |
| 100-C60…100-C97 | 35…47 | 160 | 100 | 193-T1DC47 |
| 45…60 | 200 | 125 | 193-T1DC60 | |
| 100-C72…100-C97 | 58…75 | 200 | 125 | 193-T1DC75 |
| 100-C85…100-C97 | 72…90 | 250 | 160 | 193-T1DC90 |
| ⋆ Bulletin 193-T1 overload relays shall not be used with conventional DC controlled contactors. Use electronic controlled DC versions. | ||||
| To select the setting range for use in Y-D Starters, multiply the rated operating current of the motor by a factor of 0.58. | ||||
| § For motors with service factor of 1.15 or greater, use motor nameplate full load current. For motors with service factor of 1.0, use 90% of the motor nameplate full load current. | ||||
| For Use With ⋆ | Setting Range [A] § |
Max. Back-up gL/gG fuse [A] 50 kA, 690V AC IEC/EN 60947-4-1 Coordination |
Cat. No. | |
| Type 1 | Type 2 | |||
| Separate mounting required (Panel-mounted device) | 35…47 | 160 | 100 | 193-T1DC47P |
| 45…60 | 200 | 125 | 193-T1DC60P | |
| 58…75 | 200 | 125 | 193-T1DC75P | |
| 72…90 | 250 | 160 | 193-T1DC90P | |
| ⋆ Bulletin 193-T1 overload relays shall not be used with conventional DC controlled contactors. Use electronic controlled DC versions. | ||||
| To select the setting range for use in Y-D Starters, multiply the rated operating current of the motor by a factor of 0.58. | ||||
| § For motors with service factor of 1.15 or greater, use motor nameplate full load current. For motors with service factor of 1.0, use 90% of the motor nameplate full load current. | ||||
Add-On Modules
Ä Coil Voltage Codes for Remote Reset Solenoid
| [V] | 24 | 48 | 110 | 120 | 125 | 220…240 | |
| 50 Hz | — | — | D | — | — | — | |
| 60 Hz | — | — | — | D | — | — | |
| 50/60 Hz | KJ | KY | — | — | — | KF | |
| DC | ZJ | ZY | ZD | — | ZS | — | |