| Description
|
Mounts to Contactor
|
Adjustment Range [A]
|
Cat. No.
|
| Three-Phase Devices 193-ED
|
0.1…45 A Current Range Fixed Trip Class 10 Manual Reset
|
100-C09…100-C23
|
0.1…0.5
|
193-ED1AB
|
| 0.2…1.0
|
193-ED1BB
|
| 1.0…5.0
|
193-ED1CB
|
| 3.2…16
|
193-ED1DB
|
| 5.4…27
|
193-ED1EB
|
| 100-C30…100-C43
|
5.4…27
|
193-ED1ED
|
| 9…45
|
193-ED1FD
|
1…27 A Current Range Selectable Trip Class (10, 15, 20 or 30) Selectable Manual/Auto-Manual Reset
|
Integrated panel/DIN Rail mount and pass-thru wiring
|
1.0…5.0
|
193-ED1CP
|
| 3.2…16
|
193-ED1DP
|
| 5.4…27
|
193-ED1EP
|
| Three-Phase Devices 193-EE
|
0.1…800 A Current Range Selectable Trip Class (10, 15, 20 or 30) Selectable Manual/Auto-Manual Reset
|
100-C09…100-C23
|
0.1…0.5
|
193-EEAB
|
| 0.2…1.0
|
193-EEBB
|
| 1.0…5.0
|
193-EECB
|
| 3.2…16
|
193-EEDB
|
| 5.4…27
|
193-EEEB
|
| 100-C30…100-C43
|
5.4…27
|
193-EEED
|
| 9…45
|
193-EEFD
|
| 100-C60…100-C97
|
5.4…27
|
193-EEEE
|
| 9…45
|
193-EEFE
|
| 18…90
|
193-EEGE
|
| 60…120
|
193-EEVE
|
| 100-D115…100-D180
|
60…120 ⋆
|
193-EEVF
|
| 30…150 ⋆
|
193-EEHF
|
| 40…200 ⋆
|
193-EEJF
|
| 100-D210…100-D420
|
40…200 ⋆
|
193-EEJG
|
| 60…300 ⋆
|
193-EEKG
|
| 100-D210…100-D420
|
100…500 ⋆
|
193-EELG
|
| 100-D630…100-D860
|
120…600 ⋆
|
193-EEMH
|
| 100-D630…100-D860
|
160…800 ⋆
|
193-EENH
|
1…27 A Current Range Selectable Trip Class (10, 15, 20 or 30) Selectable Manual/Auto-Manual Reset
|
Integrated panel/DIN Rail mount and pass-thru wiring
|
1.0…5.0
|
193-EECP
|
| 3.2…16
|
193-EEDP
|
| 5.4…27
|
193-EEEP
|
|
|
| ⋆ Rated operating voltage IEC: 1000V AC
|
| Description
|
CT Ratio
|
Adjustment Range [A]
|
Cat. No.
|
| Three-Phase Devices 193-EE_Z for use with external CT's (193-CBCT_)
|
30…800 A Current Range Selectable Trip Class (10, 15, 20 or 30) Selectable Manual/Auto-Manual Reset Require one external CT per phase (not supplied) (Rating for protecting relaying, Secondary current 5 A Secondary load 0.1 VA (overload relay only) Accuracy >= 2 % over operating range) Require the use of the panel adapter 193-EPB
|
150:5
|
30…150
|
193-EEHZ
|
| 200:5
|
40…200
|
193-EEJZ
|
| 300:5
|
60…300
|
193-EEKZ
|
| 400:5
|
80…400
|
193-EEWZ
|
| 500:5
|
100…500
|
193-EELZ
|
| 600:5
|
120…600
|
193-EEMZ
|
| 800:5
|
160…800
|
193-EENZ
|
|
|
| Description
|
Mounts to Contactor
|
Adjustment Range [A]
|
Cat. No.
|
| Single-Phase Devices 193-EE
|
1…90 A Current Range Selectable Trip Class (10, 15, 20 or 30) Selectable Manual/Auto-Manual Reset
|
100-C09…100-C23
|
1.0…5.0
|
193S-EEPB
|
| 3.2…16
|
193S-EERB
|
| 5.4…27
|
193S-EESB
|
| 100-C30…100-C43
|
9…45
|
193S-EETD
|
| 100-C60…100-C97
|
18…90
|
193S-EEUE
|
1…27 A Current Range Selectable Trip Class (10, 15, 20 or 30) Selectable Manual/Auto-Manual Reset
|
Integrated panel/DIN Rail mount and pass-thru wiring
|
1.0…5.0
|
193S-EEPP
|
| 3.2…16
|
193S-EERP
|
| 5.4…27
|
193S-EESP
|
|
|
|
|
Description
|
For Use With
|
PQ
|
Cat. No.
|
|
DIN Rail/Panel Adapter For separate mounting can be mounted to top-hat rail EN 50 022-35
|
193-ED1_B, 193-EE_B, 193S-EE_B, 193-EE_Z
|
1
|
193-EPB
|
| 193-ED1_D, 193-EE_D, 193S-EE_D
|
193-EPD
|
| 193-EE_E, 193S-EE_E
|
193-EPE
|
|
Current Adjustment Shield Prevents inadvertent adjustment of the current setting. Must be ordered in multiples of package quantities.
|
193-ED (all), 193-EE (all)
|
10
|
193-BC8
|
|
External Reset Adapter For enclosed, through-the-door reset applications. Use with external reset button.
|
193-ED (all) 193-EE_B, 193-EE_D, 193-EE_E, 193-EE_P, 193-EE_Z
|
1
|
193-ERA
|
|
External Reset Button For enclosed, through-the-door reset applications. Metal construction, IP66, non-illuminated. Refer to the 800F selection information for additional types.
|
All
|
1
|
800FM-R611
|
|
Reset Rod Length 142 mm, adjustable range 141…159 mm
|
All
|
1
|
800F-ATR08
|
|
|
| PQ = Package Quantity
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
E1 Plus DeviceNet and Protection Module Communicates motor diagnostic data via DeviceNet, includes additional I/O, and provides enhanced motor protection options.
|
193-EE (all), 193S-EE (all)
|
193-EDN
|
|
E1 Plus EtherNet/IP and Protection Module Communicates motor diagnostic data via EtherNet/IP, includes additional I/O, and provides enhanced motor protection options.
|
193-ETN
|
|
E1 Plus PROFIBUS and Protection Module Communicates motor diagnostic data via PROFIBUS, includes additional I/O, and provides enhanced motor protection options.
|
193-EPRB
|
|
E1 Plus Ground Fault/Jam Module Provides adjustable 20 mA…5 A ground fault and fixed jam protection. The module also provides an input to allow remote reset of a trip.⋆
|
193-EGJ
|
|
E1 Plus Ground Fault Module Provides adjustable 20 mA…5 A ground fault protection. The module also provides an input to allow remote reset of a trip.⋆
|
193-EGF
|
|
E1 Plus Jam Protection Module Provides Jam protection with adjustable trip level and trip delay setting. The module also provides an input to allow remote reset of a trip.
|
193-EJM
|
|
E1 Plus PTC Module Provides terminals for connection up to six PTC thermistor sensors. Sensors react to actual temperature and therefore provide enhanced motor protection. Module also provides an input to allow remote reset of a trip.
|
193-EPT
|
|
E1 Plus Remote Reset Module Provides an input to allow remote reset of a trip.
|
193-ERR
|
|
E1 Plus Remote Indicator Display Displays the status of an E1 Plus from the front of a panel and features a reset button. Mounts in a standard 22 mm push button cutout.
|
193-EGF, 193-EJM, 193-EGJ, 193-PTC, 193-ERR (Ser. B or later)
|
193-ERID
|
|
|
Replacement Connectors for Cat. No. 193-ERID
|
193-ERID
|
193-NCRID
|
|
|
| ⋆ Requires external ground fault sensor, Cat. No. 193-CBCT_.
|
| Only one module may be added.
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Core Balanced Ground Fault Sensor Required when using either an E1 Plus Ground Fault Protection or Ground Fault/Jam Module Required for ground fault protection with the Cat. No. 193-EC3 overload relay
|
20 mm (0.79 in.)
|
100-C09…100-C37
|
193-CBCT1
|
| 40 mm (1.57 in.)
|
100-C09…100-C97
|
193-CBCT2
|
| 63 mm (2.5 in.)
|
100-C09…100-C97, 100-D115…100-D180
|
193-CBCT3
|
| 82 mm (3.25 in.)
|
100-C09…100-C97, 100-D115…100-D420
|
193-CBCT4
|
|
DeviceNet Configuration Terminal Used to interface with objects on a DeviceNet network. Includes 1 m communications cable (193-CB1).
|
DeviceNet
|
193-DNCT
|
| 1 meter communication cable, color-coded bare leads
|
193-DNCT
|
193-CB1
|
| 1 meter communication cable, microconnector (male)
|
193-CM1
|
| Panel Mount Adapter/Door Mount Bezel Kit
|
193-DNCT-BZ1
|
|
Remote Reset Solenoid
|
24V AC, 50/60 Hz
|
E1 Plus (Series C and later)
|
193-EMRJ
|
| 110/120V AC, 50/60 Hz
|
193-EMRD
|
| 220/240V AC, 50/60 Hz
|
193-EMRA
|
| 24V DC
|
193-EMRZ24
|
| 48V DC
|
193-EMRZ48
|
| 115V DC
|
193-EMRZ01
|
|
|
|
|
Description
|
For Use With
|
Cat. No.
|
|
Terminal Lugs Set of two Protection class IP2X per IEC 60529 and DIN 40 050
|
100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F
|
100-DTB180
|
| 100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G
|
100-DTB420
|
|
Terminal Covers Protection class IP20 per IEC 60529 and DIN 40 050 For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
|
100-D115…100-D180, 193-EC_F, 193-EE_F
|
100-DTC180
|
| 100-D210...100-D420, 193-EC_G, 193-EE_G
|
100-DTC420
|
| 100-D630…100-D860, 193-EC_H, 193-EE_H
|
100-DTC860
|
| 100-D630…100-D860, 193-EC_H, 193-EE_H
|
100-DTCS860
|
|
Terminal Lugs (UL/CSA), Copper Frame Set of three
|
100-D115, 100-D140, 100-D180, 193-EC_F, 193-EE_F
|
100-DL180
|
| 100-D210…100-D420, 193-EC_G, 193-EE_G
|
100-DL420
|
| 100-D630, 100-D860, 193-EC_H, 193-EE_H
|
100-DL630
|
| 100-D630, 100-D860, 193-EC_H, 193-EE_H
|
100-DL860
|
|
|