Motor Protection

Catalogs > Essential Components Catalog (Europe) > Power > Motor Protection > Electronic Overload Relays 193-ED, 193-EE

Electronic Overload Relays 193-ED, 193-EE

Introduction Product Selection Accessories for Overload Relays
Description Mounts to Contactor Adjustment Range [A] Cat. No.
Three-Phase Devices 193-ED
  • 0.1…45 A Current Range

  • Fixed Trip Class 10

  • Manual Reset
  • 100-C09…100-C23 0.1…0.5 193-ED1AB
    0.2…1.0 193-ED1BB
    1.0…5.0 193-ED1CB
    3.2…16 193-ED1DB
    5.4…27 193-ED1EB
    100-C30…100-C43 5.4…27 193-ED1ED
    9…45 193-ED1FD
  • 1…27 A Current Range

  • Selectable Trip Class (10, 15, 20 or 30)

  • Selectable Manual/Auto-Manual Reset
  • Integrated panel/DIN Rail mount and pass-thru wiring 1.0…5.0 193-ED1CP
    3.2…16 193-ED1DP
    5.4…27 193-ED1EP
    Three-Phase Devices 193-EE
  • 0.1…800 A Current Range

  • Selectable Trip Class (10, 15, 20 or 30)

  • Selectable Manual/Auto-Manual Reset
  • 100-C09…100-C23 0.1…0.5 193-EEAB
    0.2…1.0 193-EEBB
    1.0…5.0 193-EECB
    3.2…16 193-EEDB
    5.4…27 193-EEEB
    100-C30…100-C43 5.4…27 193-EEED
    9…45 193-EEFD
    100-C60…100-C97 5.4…27 193-EEEE
    9…45 193-EEFE
    18…90 193-EEGE
    60…120 193-EEVE
    100-D115…100-D180 60…120 ⋆  193-EEVF
    30…150 ⋆  193-EEHF
    40…200 ⋆  193-EEJF
    100-D210…100-D420 40…200 ⋆  193-EEJG
    60…300 ⋆  193-EEKG
    100-D210…100-D420 100…500 ⋆  193-EELG
    100-D630…100-D860 120…600 ⋆  193-EEMH
    100-D630…100-D860 160…800 ⋆  193-EENH
  • 1…27 A Current Range

  • Selectable Trip Class (10, 15, 20 or 30)

  • Selectable Manual/Auto-Manual Reset
  • Integrated panel/DIN Rail mount and pass-thru wiring 1.0…5.0 193-EECP
    3.2…16 193-EEDP
    5.4…27 193-EEEP
      
    ⋆ Rated operating voltage IEC: 1000V AC

    Description CT Ratio Adjustment Range [A] Cat. No.
    Three-Phase Devices 193-EE_Z for use with external CT's (193-CBCT_)
  • 30…800 A Current Range

  • Selectable Trip Class (10, 15, 20 or 30)

  • Selectable Manual/Auto-Manual Reset

  • Require one external CT per phase (not supplied)

  •         (Rating for protecting relaying,
            Secondary current 5 A
            Secondary load 0.1 VA (overload relay only)
            Accuracy >= 2 % over operating range)
  • Require the use of the panel adapter 193-EPB
  • 150:5 30…150 193-EEHZ
    200:5 40…200 193-EEJZ
    300:5 60…300 193-EEKZ
    400:5 80…400 193-EEWZ
    500:5 100…500 193-EELZ
    600:5 120…600 193-EEMZ
    800:5 160…800 193-EENZ
      

    Description Mounts to Contactor Adjustment Range [A] Cat. No.
    Single-Phase Devices 193-EE
  • 1…90 A Current Range

  • Selectable Trip Class (10, 15, 20 or 30)

  • Selectable Manual/Auto-Manual Reset
  • 100-C09…100-C23 1.0…5.0 193S-EEPB
    3.2…16 193S-EERB
    5.4…27 193S-EESB
    100-C30…100-C43 9…45 193S-EETD
    100-C60…100-C97 18…90 193S-EEUE
  • 1…27 A Current Range

  • Selectable Trip Class (10, 15, 20 or 30)

  • Selectable Manual/Auto-Manual Reset
  • Integrated panel/DIN Rail mount and pass-thru wiring 1.0…5.0 193S-EEPP
    3.2…16 193S-EERP
    5.4…27 193S-EESP