Motor Protection

Catalogs > Essential Components Catalog (Europe) > Power > Motor Protection > Electronic Overload Relays 193-ED, 193-EE

Electronic Overload Relays 193-ED, 193-EE

Introduction Product Selection Accessories for Overload Relays
Accessories for Overload Relays

  Description For Use With PQ Cat. No.
Click to enlarge - ab_1 Adpt_006538 DIN Rail/Panel Adapter
For separate mounting – can be mounted to top-hat rail EN 50 022-35
193-ED1_B, 193-EE_B, 193S-EE_B, 193-EE_Z 1 193-EPB
193-ED1_D, 193-EE_D, 193S-EE_D 193-EPD
193-EE_E, 193S-EE_E 193-EPE
Click to enlarge - ab_4 timer cover_006550 Current Adjustment Shield
Prevents inadvertent adjustment of the current setting.
Must be ordered in multiples of package quantities.
193-ED (all),
193-EE (all)
10 193-BC8
Click to enlarge - ab_3 reset cover_006549 External Reset Adapter
For enclosed, through-the-door reset applications. Use with external reset button.
193-ED (all)
193-EE_B,
193-EE_D,
193-EE_E,
193-EE_P,
193-EE_Z
1 193-ERA
Click to enlarge - 800FP-R611_whiteR_4c External Reset Button
For enclosed, through-the-door reset applications. Metal construction, IP66, non-illuminated. Refer to the 800F selection information for additional types.
All 1 800FM-R611
Click to enlarge - 800F_reset_rod_4c Reset Rod
Length 142 mm, adjustable range 141…159 mm
All 1 800F-ATR08
  
PQ = Package Quantity

  Description For Use With Cat. No.
Click to enlarge - devicenet_193EDN_cmyk E1 Plus DeviceNet and Protection Module
Communicates motor diagnostic data via DeviceNet, includes additional I/O, and provides enhanced motor protection options.‡ 
193-EE (all),
193S-EE (all)
193-EDN
Click to enlarge - 193_ETN_A_right E1 Plus EtherNet/IP and Protection Module
Communicates motor diagnostic data via EtherNet/IP, includes additional I/O, and provides enhanced motor protection options.‡ 
193-ETN
Click to enlarge - 193-EPRB_right_4c E1 Plus PROFIBUS and Protection Module
Communicates motor diagnostic data via PROFIBUS, includes additional I/O, and provides enhanced motor protection options.‡ 
193-EPRB
Click to enlarge - 193_EGJ_right E1 Plus Ground Fault/Jam Module
Provides adjustable 20 mA…5 A ground fault and fixed jam protection. The module also provides an input to allow remote reset of a trip.⋆ ‡ 
193-EGJ
Click to enlarge - 193_EGF_right E1 Plus Ground Fault Module
Provides adjustable 20 mA…5 A ground fault protection. The module also provides an input to allow remote reset of a trip.⋆ ‡ 
193-EGF
Click to enlarge - 193_EJM_4c E1 Plus Jam Protection Module
Provides Jam protection with adjustable trip level and trip delay setting. The module also provides an input to allow remote reset of a trip.‡ 
193-EJM
Click to enlarge - 193_EPT_right E1 Plus PTC Module
Provides terminals for connection up to six PTC thermistor sensors. Sensors react to actual temperature and therefore provide enhanced motor protection. Module also provides an input to allow remote reset of a trip.‡ 
193-EPT
Click to enlarge - 193_ERR_right E1 Plus Remote Reset Module
Provides an input to allow remote reset of a trip.‡ 
193-ERR
Click to enlarge - 193_ERID_AB_right E1 Plus Remote Indicator Display
Displays the status of an E1 Plus from the front of a panel and features a reset button. Mounts in a standard 22 mm push button cutout.‡ 
193-EGF,
193-EJM,
193-EGJ,
193-PTC,
193-ERR (Ser. B or later)
193-ERID
  Replacement Connectors for Cat. No. 193-ERID 193-ERID 193-NCRID
  
⋆ Requires external ground fault sensor, Cat. No. 193-CBCT_.
‡ Only one module may be added.

  Description For Use With Cat. No.
Click to enlarge - 193_CBCT2_right Core Balanced Ground Fault Sensor
  • Required when using either an E1 Plus Ground Fault Protection or Ground Fault/Jam Module

  • Required for ground fault protection with the Cat. No. 193-EC3 overload relay
  • 20 mm (0.79 in.) 100-C09…100-C37 193-CBCT1
    40 mm (1.57 in.) 100-C09…100-C97 193-CBCT2
    63 mm (2.5 in.) 100-C09…100-C97, 100-D115…100-D180 193-CBCT3
    82 mm (3.25 in.) 100-C09…100-C97, 100-D115…100-D420 193-CBCT4
    Click to enlarge - 193DNCT_10_4c DeviceNet Configuration Terminal
    Used to interface with objects on a DeviceNet network. Includes 1 m communications cable (193-CB1).
    DeviceNet 193-DNCT
    1 meter communication cable, color-coded bare leads 193-DNCT 193-CB1
    1 meter communication cable, microconnector (male) 193-CM1
    Panel Mount Adapter/Door Mount Bezel Kit 193-DNCT-BZ1
    Click to enlarge - Reset_right-4c Remote Reset Solenoid 24V AC, 50/60 Hz E1 Plus (Series C and later) 193-EMRJ
    110/120V AC, 50/60 Hz 193-EMRD
    220/240V AC, 50/60 Hz 193-EMRA
    24V DC 193-EMRZ24
    48V DC 193-EMRZ48
    115V DC 193-EMRZ01
      

      Description For Use With Cat. No.
    Click to enlarge - 100-DTB_GS Terminal Lugs
  • Set of two

  • Protection class IP2X per IEC 60529 and DIN 40 050
  • 100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F 100-DTB180
    100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G 100-DTB420
    Click to enlarge - 100D-93-5 Terminal Covers
  • Protection class IP20 per IEC 60529 and DIN 40 050

  • For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
  • 100-D115…100-D180, 193-EC_F, 193-EE_F 100-DTC180
    100-D210...100-D420, 193-EC_G, 193-EE_G 100-DTC420
    100-D630…100-D860, 193-EC_H, 193-EE_H 100-DTC860
    100-D630…100-D860, 193-EC_H, 193-EE_H 100-DTCS860
    Click to enlarge - 100D-93-2 Terminal Lugs (UL/CSA), Copper Frame
    Set of three
    100-D115, 100-D140, 100-D180, 193-EC_F, 193-EE_F 100-DL180
    100-D210…100-D420, 193-EC_G, 193-EE_G 100-DL420
    100-D630, 100-D860, 193-EC_H, 193-EE_H 100-DL630
    100-D630, 100-D860, 193-EC_H, 193-EE_H 100-DL860
      

    Note:For labeling materials, see Marking Systems.