Description
|
|
Cat. No.
|
|
Basic Unit Note: The minimum requirements for a complete basic system are one basic unit and one converter module.
|
120…240V AC/DC
|
|
825-PD
|
User Manual Ships separate from Basic Unit. Please consult your local sales office.
|
825-UM004…
|
|
|
|
Converter Module
|
0.5…2.5 A
|
|
825-MCM2
|
| 2.5…20 A
|
|
825-MCM20
|
| 20…180 A
|
|
825-MCM180
|
| 160…630 A
|
|
825-MCM630N
|
|
Core Balance Ground Fault Sensor
|
100:1
|
|
825-CBCT
|
|
RTD Scanner Module 12 RTD input channels with individual programming for 10 W copper, 100 W nickel, 120 W nickel, or 100 W platinum. Fiber optic connection to Basic Unit. Class I, Division 2, Group T48.. Use an up to 500m long Simplex 62.5/125mm fiber optic cable ST/ST (customer suplied).
|
120 / 240V AC
|
|
825-PR12D
|
|
Voltage Input Card Monitoring of VA, VB, VC, and VN
|
300V AC Line to Neutral Max.
|
⋆
|
825-PVS
|
Expansion I/O Card (3) Inputs (4) Output relays (1) 4…20 mA analog output
|
120V AC Rated Inputs
|
⋆
|
825-PIOD
|
| 24V DC Rated Inputs
|
825-PIOR
|
DeviceNet Communication Card DeviceLogix technology, Node address selection switches, ODVA conformance tested.
|
⋆
|
825-PDN
|
DeviceNet User Manual Please consult your local sales office.
|
825-UM005…
|
|
|
| Modbus RTU Communication Card
|
—
|
⋆
|
825-PMB
|
|
|
| ⋆ Please consult your local sales office for factory configurated devices with option cards.
|
|
|
Description
|
Cat. No.
|
|
M8 connections Set of three 4 x 16 x 102 mm (1/8 x 5/8 x 4-1/64 in.) (125 A max.) Universally applicable Weight: 230 g
|
825-MVM
|
M8 connections Set of three 4 x 20 x 117 mm (1/8 x 25/32 x 4-39/64 in.) (180 A max.) Universally applicable
|
825-MVM2
|
|
M6 lower connections Set of three For mounting on Bul. 100-D105 and 100-D110 contactors with conventional coil
|
825-MVS
|
M8 lower connections Set of three For mounting on Bul. 100-D140, 100-D180 conventional and Bul. 100-D105E…100-D180E contactors with electronic coil
|
825-MVS2
|
|
Terminal Shields Set of two Protection class IP10 per IEC 60529 and DIN 40 050 For direct-on-line, reversing, two-speed, and wye-delta/star-delta assemblies
|
100-D115
|
100-DTS110
|
| 100-D115…100-D180, 193-FE
|
100-DTS180
|
| 100-D210...100-D420, 193-FE
|
100-DTS420
|
|
Terminal Lugs Set of two Protection class IP2X per IEC 60529 and DIN 40 050
|
100-D115
|
100-DTB110
|
| 100-D115, 100-D140, 100-D180, 100-D115E…D180E, 193-EC_F, 193-EE_F
|
100-DTB180
|
| 100-D210...100-D420, 193-EC_G, 193-EF2C, 193-EE_G
|
100-DTB420
|
|
Thermal Utilization Meter
|
For display of percent thermal capacity utilized Requires the use of an Expansion I/O Card
|
825-MTUM
|
|
|
Connection Cable (Replacement) Bul. 825-P to Bul. 825-MCM Connection
|
825-MCA
|
|
|