SMC-3 Controller

Smart Motor Controllers SMC-3

Click to enlarge - SMC_3_150_C_4c



Product Selection

Up to 480V AC

Line Connection Delta Connection 100…240V 50/60 Hz
Control
24V AC/DC
Control
Current Rating
⋆ ‡ 
Motor Power @ 400V AC §  Current Rating
⋆ ‡ 
Motor Power @ 400V AC § 
[A] [kW] [A] [kW] Cat. No. Cat. No.
1…3 1.1 1.7…5.1 0.55…2.2 150-C3NBD 150-C3NBR
3…9 4 5.1…16 2.2…7.5 150-C9NBD 150-C9NBR
5.3…16 7.5 9.1…27.6 4…11 150-C16NBD 150-C16NBR
6.3…19 7.5 10.9…32.8 4…15 150-C19NBD 150-C19NBR
9.2…27.7 11 14.3…43 5.5…22 150-C25NBD 150-C25NBR
10…30 15 17.3…52 7.5…22 150-C30NBD 150-C30NBR
12.3…37 18.5 21…64 7.5…30 150-C37NBD 150-C37NBR
14.3…43 22 25…74 11…37 150-C43NBD 150-C43NBR
20…60 30 34.6…104 15…55 150-C60NBD 150-C60NBR
28.3…85 45 50…147 22…75 150-C85NBD 150-C85NBR
27…108 55 47…187 90 150-C108NBD 150-C108NBR
34…135 75 59…234 132 150-C135NBD 150-C135NBR
67…201 95…110 116…348 160 150-C201NBD 150-C201NBR
84…251 95…132 145…435 250 150-C251NBD 150-C251NBR
106…317 95…160 183…549 315 150-C317NBD 150-C317NBR
120…361 110…200 208…625 355 150-C361NBD 150-C361NBR
160…480 160…250 277…831 450 150-C480NBD 150-C480NBR
  
⋆ Motor FLA and Motor Running Current must fall within the running current range of the device to operate properly.
‡  From series letter "B", these units can be used in the inside the delta wiring with a current range 1.73 x higher
§ Calculated using 350 % over current during starting.

Description N.O. N.C. Connection Diagram Cat. No.
Click to enlarge - 150-7_66-1 Auxiliary Contact Blocks for side mounting with sequence terminal designations
1- and 2-pole
Quick and easy mounting without tools
One block per device only
1 0 Click to enlarge - 150-7_66-2 Click to enlarge - 150-7_66-3 Click to enlarge - 150-7_66-4 Click to enlarge - 150-7_66-5 150-CA10
2 0 150-CA20
0 1 150-CA01
1 1 150-CA11
  

Description For Use With Cat. No.
Click to enlarge - 150-7_66-6 Fan
Field installed
150-C3…37 ⋆  150-CF64
Click to enlarge - 150-7-66-7 Connecting modules to 140-M
Electrical interconnection between SMC-3 and 140-M.
Motor protector and SMC must be mounted separately.
Connects 140-M-C to
150-C3…25
150-CC25
Connects 140-M-D to
150-C3…25
150-CD25
Connects 140-M-F to
150-C3…37
150-CF45
Click to enlarge - 150-7-66-8 Connecting modules to 100-C
Electrical interconnection between SMC-3 and 100-C.
Contactor and SMC must be mounted separately.
Connects 100-C09…23 to
150-C3…19
150-CI23
Connects 100-C30…37 to
150-C3…37
150-CI37
Click to enlarge - 150-7_66-9 480V Protective Module 150-C3…37NB 150-C84
150-C43…85NB (line and/or load) 150-C84P
600V Protective Module 150-C3…37NC 150-C86
150-C43…85NC (line and/or load) 150-C86P
IEC Terminal Covers ‡ 
Click to enlarge - 150-7-76-3 IEC line or load terminal covers for 108 and 135 A devices.
Dead front protection
150-TC1
IEC line or load terminal covers for 201…251 A devices.
Dead front protection
150-TC2
IEC line or load terminal covers for 317…480 A devices.
Dead front protection
150-TC3
  
⋆ For devices above this range, the fan is shipped with the device as standard.
‡ One terminal cover is shipped as standard with the SMC-3 controllers from 108…480 A.