Motor Current [A] 400V [kW] Motor Current [A] 400V [kW] Cat. No. Cat. No.
1…5 2.2 1.7…8.7 4 150-F5NBD 150-F5NBDB
5...25 11 8.7…43 22 150-F25NBD 150-F25NBDB
8.6...43 22 14.9…74 37 150-F43NBD 150-F43NBDB
12...60 30 20.8…104 55 150-F60NBD 150-F60NBDB
17...85 45 29.4…147 75 150-F85NBD 150-F85NBDB
27…108 55 47…187 90 150-F108NBD 150-F108NBDB
34…135 75 59…234 132 150-F135NBD 150-F135NBDB
67…201 110 116…348 160 150-F201NBD 150-F201NBDB
84…251 132 145…435 250 150-F251NBD 150-F251NBDB
106…317 160 183…549 315 150-F317NBD 150-F317NBDB
120…361 200 208…625 355 150-F361NBD 150-F361NBDB
160…480 250 277…831 450 150-F480NBD 150-F480NBDB
208…625 355 283…850 500 150-F625NBA 150-F625NBAB
260…780 450 300…900 500 150-F780NBA 150-F780NBAB
323…970 560 400…1200 710 150-F970NBA 150-F970NBAB
416…1250 710 533…1600 900 150-F1250NBA 150-F1250NBAB
  
⋆ Controllers rated 108 A and greater are not equipped with line and load terminal lugs.
‡ Motor FLA and motor running current must fall within the running current range of the device to operate properly.
§ Utilization category: 5…480 A: AC-53b: 3-50: 1750 / 625…1250 A: AC-53b: 3.0-50: 3550
♣ Reduced control voltage range for devices from 625…1250 A. See configuration table in section "b".

Optional Configurations

150-F108N B D B
  a b c

a
Options Voltage Range
B Up to 480V AC
C Up to 600V AC
Z Up to 690V AC (108…1250 A types only)

b
Options Control Voltage
D 100…240V AC 50/60 Hz (5…480 A units)
R 24 V AC/DC (5…480 A units)
E 110/120 V AC (625…1250 A units)
A 230/240 V AC (625…1250 A units)

c
Options Description
Blank Standard
B Pump Control
Provides smooth motor acceleration and deceleration, reducing surges caused by the starting and stopping of centrifugal pumps. Starting time is adjustable from 0…30 seconds, and stopping time is adjustable from 0…120 seconds.
D Braking Control
Provides Smart Motor Braking (SMB), Accu-Stop, and Slow Speed with Braking. Prices on request.

Description Cat. No.
Protective Modules ⋆ 
Click to enlarge - 150-7-76-1 480V Protective Module 5…85 A 150-F84
90...180 A 150-F84L
600V Protective Module 5…85 A 150-F86
108…1250 A 150-F86L
IEC Terminal Covers ‡ 
Click to enlarge - 150-7-76-3 IEC line or load terminal covers for 108 and 135 A devices.
Dead front protection
150-TC1
IEC line or load terminal covers for 201…251 A devices.
Dead front protection
150-TC2
IEC line or load terminal covers for 317…480 A devices.
Dead front protection
150-TC3
Human Interface Modules
Click to enlarge - 150-7-76-4 Hand Held
Human Interface Modules
LCD Display, Full Numeric Keypad  §  20-HIM-A3
LCD Display, Programmer Only  §  20-HIM-A5
Enhanced, LCD Display, Full Numeric Keypad §  20-HIM-A6
Door Mounted
Human Interface Modules
Remote (Panel Mount) LCD Display, Full Numeric Keypad 20-HIM-C3S
Remote (Panel Mount) LCD Display, Programmer Only 20-HIM-C5S
Enhanced, Remote (Panel Mount) LCD Display, Full Numeric Keypad 20-HIM-C6S
Human Interface Module
Interface Cables
PowerFlex HIM Interface Cable, 1 m (39 in) 20-HIM-H10
Communication Modules
Click to enlarge - 20-comm-d Communication Modules (IP30/Type 1) RS485 DF1 Communication Adapter 20-COMM-S
PROFIBUS™ DP Communication Adapter 20-COMM-P
HVAC Communication Adapter 20-COMM-H
ControlNet™ Communication Adapter (Fiber) 20-COMM-Q
ControlNet™ Communication Adapter (Coax) 20-COMM-C
DeviceNet™ Communication Adapter 20-COMM-D
EtherNet/IP™ Communication Adapter 20-COMM-E
Core Balance Transformer
Click to enlarge - 825-CBCT_CoreBal_4c Core Balance Ground Fault Sensor 100:1 825-CBCT
  
⋆ The same protective module mounts on the line or load side of the SMC-Flex. For applications requiring both line and load side protection, two protective modules must be ordered.
‡ One terminal cover is shipped as standard with the SMC-Flex controllers from 108…480 A.
§ Requires a 20-HIM-H10 cable to connect to the SMC-Flex.