ArmorStart™ Distributed Motor Controllers
Product Line Overview
|
|
|
||||
| Bulletin | 280D/281D | 280A/281A | 283D | 283A | 284D | 284A |
| Power Range: | ||||||
| 0.18…7.5 kW (0.5…10 Hp) | ü | ü | — | — | — | — |
| 0.37…5.5 kW (0.5…10 Hp) | — | — | ü | ü | — | — |
| 0.4…3.3 kW (0.5…5 Hp) | — | — | — | — | ü | ü |
| Starting Method: | ||||||
| Full Voltage and Reversing | ü | ü | — | — | — | — |
| Current Limit, Soft Start, Soft Stop | — | — | ü | ü | — | — |
| Sensorless Vector Control | — | — | — | — | ü | ü |
| Environmental Rating: | ||||||
| IP67/NEMA Type 4 | ü | ü | ü | ü | ü | ü |
| IP69/NEMA Type 4X | ü | ü | ü | ü | ü | ü |
| Control Voltage Ratings: | ||||||
| 24V DC, 120V AC, and 240V AC | ü | ü | ü | ü | ü | ü |
| Operational Voltage Ratings: | ||||||
| 240 / 480 / 600V AC | ü | ü | ü | ü | ü | ü |
| Network Communications with DeviceNet including DeviceLogix | ü | — | ü | — | ü | — |
| Network Communications via ArmorPoint Distributed I/O | — | ü | — | ü | — | ü |
| I/O Capability: | ||||||
| 4 Inputs and 2 Outputs | ü | — | ü | — | ü | — |
| 2 Outputs | — | ü | — | ü | — | ü |
| I/O Expansion with ArmorPoint Distributed I/O Products | ü | ü | ü | ü | ü | ü |
| LED Status Indication | ü | ü | ü | ü | ü | ü |
| Gland Plate Entry: | ||||||
| Three phase input through cord grip or quick | ü | ü | ü | ü | ü | ü |
| Quick Disconnects (I/O, Communications, Motor Connection, Three Phase and Control Power) | ü | ü | ü | ü | ü | ü |
| Factory Installed Options: | ||||||
| HOA Keypad | ü | ü | ü | ü | ü | ü |
| Safety Monitor | ü | ü | ü | ü | ü | ü |
| Source Brake Contactor | — | — | ü | ü | ü | ü |
| Dynamic Brake Connector | — | — | — | — | ü | ü |
| Output Contactor | — | — | — | — | ü | ü |
| EMI Filter | — | — | — | — | ü | ü |
| Shielded Motor Cable | — | — | — | — | ü | ü |
| 0…10V Analog Input | — | — | — | — | ü | ü |
| Product Selection | See Bulletin 280/281 | See Bulletin 283 | See Bulletin 284 | |||
| This catalog shows main products only. For other versions refer to the detailed documentation or visit our website. | ||||||
Bulletin 280/281
|
- On-Machine starting solution
- Full-Voltage and reversing
- Robust IP67/NEMA Type 4/4X enclosure rating
- Modular plug and play design
- Quick disconnect connections for I/O, communications, motor, three phase and control power
- Gland plate entry: conduit entrance or ArmorConnect™ power media
- 4 inputs and 2 outputs (expandable with ArmorPoint™)
- LED status indication
- DeviceNet™ communications
- DeviceLogix™ component technology
- Connectivity to ArmorPoint distributed I/O products
- ControlNet and EtherNet communications via ArmorPoint
- Factory Installed Options:
- Hand/Off/Auto (HOA) keypad configuration
- Safety monitor
- Hand/Off/Auto (HOA) keypad configuration
Full-voltage and Reversing Starters with DeviceNet™ Communications, Up to 600V AC, IP67
| Current Rating | 400V AC (50 Hz) | 24V DC Control Voltage | |
| Full Voltage Starters | Reversing Starters | ||
| [A] | [kW] | Cat. No. | Cat. No. |
| 0.24…1.2 | 0.37 | 280D-F12Z-10A-CR | 281D-F12Z-10A-CR |
| 0.5…2.5 | 0.75 | 280D-F12Z-10B-CR | 281D-F12Z-10B-CR |
| 1.1…5.5 | 2.2 | 280D-F12Z-10C-CR | 281D-F12Z-10C-CR |
| 3.2…16 | 7.5 | 280D-F23Z-25D-CR | 281D-F23Z-25D-CR |
Options Factory Installed
Other ArmorStart versions available. Please consult publication 280-SG001… for complete product information.
Bulletin 283
|
- On-Machine starting solution
- Solid-State motor control
- Robust IP67/NEMA Type 4/4X enclosure rating
- Modular plug and play design
- Quick disconnect connections for I/O, communications, motor, three phase and control power
- Gland plate entry: conduit entrance or ArmorConnect™ power media
- 4 inputs and 2 outputs (expandable with ArmorPoint™)
- LED status indication
- DeviceNet™ communications
- DeviceLogix™ component technology
- Connectivity to ArmorPoint distributed I/O products
- ControlNet and EtherNet communication via ArmorPoint
- Factory Installed Options:
- HOA keypad configuration
- Source brake contactor
- Safety Monitor
- HOA keypad configuration
Controllers with DeviceNet™ Communications, Up to 480V AC, IP67
| Current Rating | 400V AC (50 Hz) | 24V DC Control Voltage |
| [A] | [kW] | Cat. No. |
| 1.1…3.0 | 1.1 | 283D-FB3Z-10A-CR |
| 3.0…5.5 | 2.2 | 283D-FB9Z-10B-CR |
| 5.3…7.6 | 3 | 283D-FB16Z-10C-CR |
| 6.3…16 | 5.5 | 283D-FB19Z-25D-CR |
Options Factory Installed
| Description | Cat. No. Modification |
| Hand Off-Auto Selector Keypad with JOG Function | -3 |
| Supplied without motor cable | -CRW |
| Source Brake Contactor | -SB |
| Supplied without source brake cable | -SBW |
| Safety Monitor | -SM |
| For factory installed options, please contact your local sales office. | |
Other ArmorStart versions available. Please consult publication 280-SG001… for complete product information.
Bulletin 284
|
- On-Machine starting solution
- Variable frequency AC drive using PowerFlex™ technology
- Power range 0.4…3 kW (0.5…5 Hp)
- Robust IP67/NEMA Type 4/4X enclosure rating
- Modular plug and play design
- Quick disconnect connections for I/O, communications, motor, three phase and control power
- Gland plate entry: conduit entrance or ArmorConnect™ power media
- 4 inputs and 2 outputs (expandable with ArmorPoint™)
- LED status indication
- DeviceNet™ communications
- DeviceLogix™ component technology
- Connectivity to ArmorPoint™ distributed I/O products
- ControlNet and EtherNet communication via ArmorPoint
- Factory Installed Options:
- Hand/Off/Auto (HOA)
- Control brake contactor
- keypad configuration
- Source brake contactor
- EMI filter
- Shielded motor cable
- Dynamic brake connector
- Safety monitor
- Output contactor
- 0…10V analog input
- Hand/Off/Auto (HOA)
Controllers with DeviceNet™ Communications, Sensorless Vector Control, Up to 480V AC, IP67
| Input Voltage | 3-Phase kW Rating | Output Current | 24V DC Control Voltage |
| [A] | Cat. No. | ||
| 200...240V, 50/60 Hz 3-Phase |
0.4 | 2.3 | 284D-FVB2P3Z-10-CR-EMI |
| 0.75 | 5 | 284D-FVB5P0Z-10-CR-EMI | |
| 1.5 | 7.6 | 284D-FVB7P6Z-25-CR-EMI | |
| 380...480V, 50/60 Hz 3-Phase |
0.4 | 1.4 | 284D-FVD1P4Z-10-CR-EMI |
| 0.75 | 2.3 | 284D-FVD2P3Z-10-CR-EMI | |
| 1.5 | 4 | 284D-FVD4P0Z-10-CR-EMI | |
| 2.2 | 6 | 284D-FVD6P0Z-25-CR-EMI | |
| 3 | 7.6 | 284D-FVD7P6Z-25-CR-EMI | |
Options Factory Installed
| Description | Cat. No. Modification | Description | Cat. No. Modification | |
| Hand Off-Auto Selector Keypad with JOG Function | -3 | Supplied without motor cable — Extended motor cable lengths available on request. | -CRW | |
| 0…10V Analog Input | -A10 | Dynamic Brake Connector | -DB | |
| Output Contactor | -OC | Shielded Motor Cable | -CRN | |
| EMI Filter | -EMI | Supplied without source brake cable | -SBW | |
| Control Brake Contactor | -CB | Safety Monitor | -SM | |
| Source Brake Contactor | -SB | |||
| For factory installed options, please contact your local sales office. | ||||
Other ArmorStart versions available. Please consult publication 280-SG001… for complete product information.