Description
|
Frame Size
|
Cat. No.
|
|
Auxiliary Contact (AX) Electrically indicates "ON/OFF" status of breakers
|
1 C/O
|
H, J, L
|
140U-H-EA1
|
| M
|
140U-M-EA1
|
| N
|
140U-N-EA1
|
| 2 C/O
|
H, J, L
|
140U-H-EA2
|
| M
|
140U-M-EA2
|
| N
|
140U-N-EA2
|
Alarm Contact (AL) Electrically indicates when the breaker is in the "TRIPPED" state
|
1 C/O (E.M./L.B.)
|
H
|
140U-H-ER1
|
| J, L
|
140U-J-ER1
|
| M
|
140U-M-ER1
|
| N
|
140U-N-ER1
|
|
Auxiliary/Alarm Contact (AX/AL) Combination Combination of auxiliary contact and alarm contact
|
1 C/O (E.M./L.B.)
|
H
|
140U-H-EA1R1
|
| J, L
|
140U-J-EA1R1
|
| M
|
140U-M-EA1R1
|
| N
|
140U-N-EA1R1
|
|
Shunt Trip (SNT) Provides remote tripping of the circuit breaker Undervoltage trip not available when shunt trip is used
|
24…60 V, 50/60/DC
|
H, J, L
|
140U-H-SNJ
|
| 110…240V, 50/60/DC
|
140U-H-SND
|
| 380…440V AC, 220…250V DC
|
140U-H-SNN
|
| 380…600V, 50/60 Hz
|
140U-H-SNB
|
| 12…24V, 50/60/DC
|
M
|
140U-M-SNJ
|
| 110…240V AC, 110…125V DC
|
140U-M-SND
|
| 380…440V AC, 220…250V DC
|
140U-M-SNN
|
| 480…600V, 50/60 Hz
|
140U-M-SNB
|
| 12…24V, 50/60/DC
|
N
|
140U-N-SNJ
|
| 110…240V AC
|
140U-N-SND
|
| 380…440V AC, 220…250V DC
|
140U-N-SNN
|
| 480…600V, 50/60 Hz
|
140U-N-SNB
|
Undervoltage Release (UVT) Automatically trips breaker when voltage falls between preset value, 35…70% Shunt trip is not available when undervoltage release is used
|
24V, 50/60Hz AC; 24V DC
|
H, J, L
|
140U-H-UJ
|
| 110…127V, 50/60 Hz
|
140U-H-UD
|
| 208…240V, 50/60 Hz
|
140U-H-UA
|
| 380…500V, 50/60 Hz
|
140U-H-UB
|
| 24V, 50/60 Hz
|
M
|
140U-M-UJ
|
| 110…127V, 50/60 Hz
|
140U-M-UD
|
| 208…240V, 50/60 Hz
|
140U-M-UA
|
| 380…500V, 50/60 Hz
|
140U-M-UB
|
| 24V, 50/60 Hz
|
N
|
140U-N-UJ
|
| 110…127V, 50/60 Hz
|
140U-N-UD
|
| 208…240V, 50/60 Hz
|
140U-N-UA
|
| 380…500V, 50/60 Hz
|
140U-N-UB
|
|
|
|
|
Description
|
Frame Size
|
PQ
|
Cat. No.
|
|
Terminal Shields IP20 Ingress Protection Rating
|
3-pole MCCBs
|
H
|
1
|
140U-H-TS
|
| I
|
140U-I-TS1
|
| J
|
140U-J-TS
|
| L
|
140U-L-TS
|
|
Phase Barriers Provides additional phase clearance when special connections that extend past the circuit breaker housing are required
|
3-pole MCCBs
|
H
|
2
|
140U-H-PB
|
| I
|
140U-I-PB
|
| J
|
140U-J-PB
|
| L
|
140U-L-PB
|
| M
|
140U-M-PB
|
| N
|
140U-N-PB
|
|
Rotary, Direct Couple Operating Mechanism Rotary handle - IP42 UL Type 1 Breaker mounted
|
Black Handle
|
H
|
1
|
140U-H-RCB
|
| I
|
140U-I-RCB
|
| J
|
140U-J-RCB
|
| L
|
140U-L-RCB
|
| Red/Yellow Handle
|
H
|
1
|
140U-H-RCR
|
| J
|
140U-J-RCR
|
| L
|
140U-L-RCR
|
|
Rotary, Variable-Depth Operating Mechanism Rotary handle - IP66, UL Type 3/12/4/4X 12 in. (30.48 cm) operating rod Operating rod 30.5 cm
|
Black Handle
|
H
|
1
|
140U-H-RVM12B
|
| J
|
140U-J-RVM12B
|
| L
|
140U-L-RVM12B
|
| M
|
140U-M-RVM12B
|
| N
|
140U-N-RM12B
|
| Red/Yellow Handle
|
H
|
1
|
140U-H-RVM12R
|
| J
|
140U-J-RVM12R
|
| L
|
140U-L-RVM12R
|
| M
|
140U-M-RVM12R
|
Rotary, Variable-Depth Operating Mechanism Rotary handle - IP66, UL Type 3/12/4/4X 21 in. (53.34 cm) operating rod Operating rod 53 cm
|
Black Handle
|
H
|
1
|
140U-H-RVM21B
|
| J
|
140U-J-RVM21B
|
| L
|
140U-L-RVM21B
|
| M
|
140U-M-RVM21B
|
| Red/Yellow Handle
|
H
|
1
|
140U-H-RVM21R
|
| J
|
140U-J-RVM21R
|
| L
|
140U-L-RVM21R
|
| M
|
140U-M-RVM21R
|
|
End Cap Kit Provides three-phase connections for terminal or bolt-on connections Metric hardware provided
|
3-pole MCCBs
|
H
|
1
|
140U-H-ECM
|
| I
|
1
|
140U-I-ECM
|
| J
|
1
|
140U-J-ECM
|
| L
|
1
|
140U-L-ECM
|
|
Replacement Mounting Hardware (4) M4 - 0.7 x 75 mm
|
3- or 4-pole MCCBs
|
H
|
1
|
140U-H-MHM
|
| I
|
1
|
140U-I-MHM
|
| J
|
1
|
140U-J-MHM
|
| L
|
1
|
140U-L-MHM
|
| M, N
|
1
|
140U-M-MHM
|
|
|
| PQ = Package Quantity
|