Catalogs > Essential Components Catalog (Europe) > Logic > Solid State Devices > Hockey Puck Relays 700-SH
Hockey Puck Relays 700-SH
| Input-to-Output Isolation Method | Zero Cross Function | Status Indicator | Output (Load) Max. Continuous Current and Rated Voltage Range ⋆ | Rated Input Control Voltage | Cat. No. |
| Optocoupler | Yes | Yes | 10 A @ 42…265V AC | 3…32V DC | 700-SH10JZ24 |
| 200…260V AC | 700-SH10JA22 | ||||
| 10 A @ 42…530V AC | 4…32V DC | 700-SH10HZ25 | |||
| 25 A @ 42…530V AC | 700-SH25HZ25 | ||||
| 25 A @ 24…265V AC | 3…32V DC | 700-SH25GZ24 | |||
| 20…280V AC/22…48V DC | 700-SH25GA24 | ||||
| 50 A @ 24…265V AC | 3…32V DC | 700-SH50GZ24 | |||
| 20…280V AC/22…48V DC | 700-SH50GA24 | ||||
| 50 A @ 42…530V AC | 4…32V DC | 700-SH50HZ25 | |||
| 25 A @ 42…660V AC | 700-SH25VZ25 | ||||
| 20…280V AC/22…48V DC | 700-SH25VA24 | ||||
| 50 A @ 42…660V AC | 4…32V DC | 700-SH50VZ25 | |||
| 20…280V AC/22…48V DC | 700-SH50VA24 | ||||
| 75 A @ 42…530V AC | 4…32V DC | 700-SH75HZ25 | |||
| 75 A @ 42…660V AC | 700-SH75VZ25 | ||||
| 75 A @ 42…530V AC | 20…280V AC/22…48V DC | 700-SH75HA24 | |||
| 75 A @ 42…660V AC | 700-SH75VA24 | ||||
| 100 A @ 42…530V AC | 4…32V DC | 700-SH100HZ25 | |||
| 20…280V AC/22…48V DC | 700-SH100HA24 | ||||
| 100 A @ 42…660V AC | 4…32V DC | 700-SH100VZ25 | |||
| 20…280V AC/22…48V DC | 700-SH100VA24 | ||||
| DC | No | 5A @ 3...60V DC | 3…32V DC | 700-SH5FZ24 | |
| Analog | Yes | 25 A @ 90…280V AC | 4…20 mA DC | 700-SH25WA25 | |
| 50 A @ 90…280V AC | 700-SH50WA25 | ||||
| ⋆ This type is also called Phase Angle 0 when used with heat sink. | |||||