Product Line Overview
Residual Current Devices 1492-RCDMiniature Circuit Breakers 1492-SP
|
|
|
| Bulletin | 1492-RCD | 1492-SP |
| Type | Residual Current Device | Miniature Circuit Breaker |
| Features | ||
| Number of Poles | 2 pole (1 + N) 4 pole (3 + N) |
1, 2, 3 pole 1 pole + neutral, 3 pole + neutral |
| Rated voltage | 230V AC (1+N), 400V AC (3+N) | 230/400V AC, 240/415V AC |
| Tripping characteristic reference temperature |
— | 30 °C |
| Rated tripping current | 30, 100, 300, 500 mA | — |
| Sensitivity | AC and pulsating DC | — |
| Rated short circuit capability |
10 kA with 63 A gG/gL back-up fuse for up to 63 A 10 kA with 80 A gG/gL back-up fuse for 80 A |
10 kA |
| Max. back-up fuse for short circuit protection |
63 A gG/gL for up to 63 A 80 A gG/gL for 80 A |
100 A gG/gL |
| Maximum back-up fuse for overload protection |
25 A gG/gL (25 A and 40 A devices) 40 A gG/gL (63 A devices) 50 A gG/gL (80 A devices) |
— |
| Degree of protection | IP20 | IP20 |
| Mechanical life | ³10000 changeovers | ³6000 changeovers |
| Mounting | 35 mm hut (DIN) rail | 35 mm hut (DIN) rail |
| Operating temperature | -5°C…+40°C | -5°C…+40°C (reduction factors are required for higher temperatures ) |
| Wire size | 1.5…35 mm2 | 1…25 mm2 |
| Terminal torque | 2.4 N.m £40 A, 3.0 N.m ³63 A | 2.4 N.m |
| Standards and Approvals | IEC/EN 61008 VDE, CE |
IEC/EN 60889 CE, VDE, UL 1077, CSA 22.2 No. 235 |
| Product Selection | See Residual Current Devices Bulletin 1492-RCD | See Miniature Circuit Breakers Bulletin 1492-SP |
Miniature Circuit Breakers 1489
Fuse Holders 1492-FB
|
|
|
|||||||
| Bulletin | 1489 | 1492-FB | ||||||
| Type | 480Y/277V AC | 240V AC | For Class CC Fuse | For Class J Fuse | For Midget Fuse | |||
| 0.5…25 A | 0.5…40 A | 30 A | 30 A | 60 A | 30 A | |||
| Features | - 0.5...40 A @ 240, 415V AC - 15,000 A interrupting |
|||||||
| Certifications | UL 489 Listed (CSA C22.2 No. 5.1), UL File Number E197878 VDE (SEC 60 947-2) |
CE, ULus, CSA | CE, URus, CSA | |||||
| Maximum Voltage Rating | 480Y/277V AC | 600V AC/DC | ||||||
| Shock | 25 G Half Sine Wave for 11 ms (Three Axes) | 25 G Half Sine Wave for 11 ms (Three Axes) | ||||||
| Tripping Characteristic Reference Temperature | 40°C (UL/CSA) 30°C (IEC) |
NA | ||||||
| Tripping Characteristic | C Curve: 5…10 D Curve: 10…20 |
NA | ||||||
| Vibration | 100...500 Hz for 1 hour Amplitude — 10...57 Hz; 0.030 inches peak to peak; 57...500 Hz; 5 G peak |
5 G peak or 0.030 "peak-to-peak" displacement for 2 hours in each perpendicular direction. Vibration sweep 10 to 2000 to 10 Hz (15 minutes long) | ||||||
| Operating Temperature | -13...140°F (-25...+55°C), non-condensing |
-4...130°F (20…+55°C) | ||||||
| Housing Material | Nylon | Nylon | ||||||
| Working Voltage | — | 110…600V AC/DC or 12…72V AC/DC | 110…600V AC/DC | 110…600V AC/DC or 12…72V AC/DC | ||||
| With Indicator | Leakage Current | LED | — | 2.0 mA | ||||
| Wire Size | 0.8...13 mm2/#18...6 AWG Cu | #16…4 AWG Cu | #14…1 AWG Cu | #10…1 AWG Cu | #16…4 AWG Cu | |||
| Interrupt Rating | 10 kA @ 240V AC and 480Y/277V AC (UL/CSA) |
200 kA | 50 kA | |||||
| Product Selection | See Miniature Circuit Breakers Bulletin 1489 | See DIN Rail Mounting Fuse Holders 1492-FB | ||||||
Fuse Holders 140F
|
|
| Bulletin | 140F |
| Type | MCS Fuse Holders |
| Features | |
| Product Selection | See MCS Fuse Holders 140F |