Connectivity

Catalogs > Essential Components Catalog (Europe) > Connectivity > Distributed I/O

Distributed I/O

Quick Selection ArmorBlock Digital I/O Blocks
ArmorBlock Digital I/O Blocks

Click to enlarge - 1732_4c



ArmorBlock I/O — DeviceNet

Description Cat. No.
DeviceNet, Input Module, 8 Sink Inputs, Pico (M8) connector 1732D-IB8M8
DeviceNet, Input Module, 8 Sink Inputs, DC Micro (M12) connector 1732D-IB8M12
DeviceNet, Input Module, 16 Sink Inputs, DC Micro (M12) connector 1732D-IB16M12M12
DeviceNet, Input Module, 16 Sink Inputs, DC Micro (Mini) connector 1732D-IB16M12MINI
DeviceNet, Output Module, 8 Source Outputs, Pico (M8) connector 1732D-OB8EM8
DeviceNet, Output Module, 8 Source Outputs, DC Micro (M12) connector 1732D-OB8EM12
DeviceNet, Output Module, 16 Source Outputs, DC Micro (M12) connector 1732D-OB16M12M12
DeviceNet, Output Module, 16 Source Outputs, DC Micro (Mini) connector 1732D-OB16M12MINI
DeviceNet, Self-configuring Module, 8 point I/O, Pico (M8) connector 1732D-8CFGM8
DeviceNet, Self-configuring Module, 8 point I/O, DC Micro (M12) connector 1732D-8CFGM12
DeviceNet, Self-configuring Module, 16 point I/O, DC Micro (M12) connector 1732D-16CFGM12M12
DeviceNet, Self-configuring Module, 16 point I/O, DC Micro (Mini) connector 1732D-16CFGM12MN
  

ArmorBlock I/O — EtherNet/IP

Description Cat. No.
EtherNet, Input module, 16 points, DC Micro (M12) connector 1732E-IB16M12
EtherNet, Output module, 16 points, DC Micro (M12) connector 1732E-OB16M12
EtherNet, Self-configuring, 16 points, DC Micro (M12) connector 1732E-16CFGM12
  

ArmorBlock I/O — EtherNet/IP Dual Port

Description Cat. No.
EtherNet/IP Dual Port, Input Module, 16 points, DC Micro(M12) connector 1732E-IB16M12R
EtherNet/IP Dual Port, Input Module, 16 points, Diagnostics, DC Micro(M12) connector 1732E-IB16M12DR
EtherNet/IP Dual Port, 8 Inputs, 8 Outputs, Diagnostics, DC Micro(M12) connector 1732E-8X8M12DR
EtherNet/IP Dual Port, Output Module, 16 points, DC Micro(M12) connecto 1732E-OB16M12R
EtherNet/IP Dual Port, Output Module, 16 points, Diagnostics, DC Micro(M12) connector 1732E-OB16M12DR
EtherNet/IP Dual Port, Self-configuring Module, 16 points, DC Micro(M12) connector 1732E-16CFGM12R
  

Cables and Cordsets

The Cable and Cordset tables list the most common cable, patchcords, and cordsets for the I/O module.

You can also find additional information on selecting cables and cordsets for ArmorBlock I/O in these publications:



ArmorBlock I/O Cables

For Using: Recommended Patchcord
(double-ended)
Recommended Male Cordset
(single-ended)
Cat. No.
2 inputs per connector 879D-F4ACDM-x 879-C3AEDM4-5 1732D-IB8M12
1 input per connector 889D-F4ACDM-x 889D-M4AC-x
3-pin pico connectors 889P-F3ABPM-x 889P-M3AB-y 1732D-IB8M8
4-pin pico connectors 889P-F4ABPM3-x
2 inputs per connector 879D-F4ACDM-x 879-C3AEDM4-5 1732D-OB8EM12
1 input per connector 889D-F4ACDM-x
3-pin pico connectors 889P-F3ABPM-x 889P-M3AB-y 1732D-OB8EM8
4-pin pico connectors 889P-F4ABPM3-x 889P-M3AB-y
2 inputs per connector 879D-F4ACDM-x 879-C3AEDM4-5 1732D-8CFGM12
1 input per connector 889D-F4ACDM-x 889D-M4AC-x
3-pin pico connectors 889P-F3ABPM-x 889P-M3AB-y 1732D-8CFGM8
4-pin pico connectors 889P-F4ABPM3-x
  
x = length in meters (1, 2, 3, 5, and 10 standard).
y = length in meters (2, 5, and 10 standard).

ArmorBlock DeviceNet and Auxiliary Power Cables

Recommended DeviceNet Cable Recommended Auxiliary Power Cables Cat. No.
KwikLink Flat Media system standard drop cable:
1485K-PzF5-R5
Thick Round system standard drop cable:
1485R-PzM5-R5
Thin Round system standard drop or trunk:
1485R-PzR5-D5
Standard Cordset (single-ended):
889D-F4AC-y
Standard Patchcord (double-ended):
889D-F4ACDM-x
1732D-IB8M12
1732D-IB8M8
1732D-OB8EM12
1732D-OB8EM8
1732D-8CFGM12
1732D-8CFGM8
  
x = length in meters (1, 2, 3, 5, and 10 standard).
y = length in meters (2, 5, and 10 standard).