| Process Connection
|
Pressure Range (psig)
|
Set Point Range (psig)
|
Reset Point Range (psig)
|
Maximum Working Pressure (psig)⋆
|
Cat. No.
|
| 1/4 inch NPT (female)
|
-15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DA1CC1D4
|
| 0…60
|
0.30…60
|
0…59.70
|
160.5
|
836E-DA1EL1D4
|
| 0…150
|
0.75…150
|
0…149.25
|
400.5
|
836E-DA1EN1D4
|
| 0…600
|
3.00…600
|
0…597.00
|
1600.5
|
836E-DA1EQ1D4
|
| 0…1,500
|
7.50…1,500
|
0…1,492.50
|
1600.5
|
836E-DA1ER1D4
|
| 0…400 (bar)
|
2.07…413.79 (bar)
|
0…400 (bar)
|
400 (bar)
|
836E-DA1EU1D4
|
| SAE 7/16-20 UNF (female)
|
-15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DA1CC2D4
|
| 0…60
|
0.30…60
|
0…59.70
|
160.5
|
836E-DA1EL2D4
|
| 0…150
|
0.75…150
|
0…149.25
|
400.5
|
836E-DA1EN2D4
|
| 0…600
|
3.00…600
|
0…597.00
|
1600.5
|
836E-DA1EQ2D4
|
| 0…1,500
|
7.50…1,500
|
0…1,492.50
|
1600.5
|
836E-DA1ER2D4
|
| -15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DA1EU2D4
|
| G1/4 BSPP (female)
|
-1…1 (bar)
|
-1.0…+1.03 (bar)
|
-1.03…1 (bar)
|
2.7 (bar)
|
836E-DA1CC3D4
|
| 0…4 (bar)
|
0.02…4.14 (bar)
|
0…4 (bar)
|
10.7 (bar)
|
836E-DA1EL3D4
|
| 0…10 (bar)
|
0.05…10.30 (bar)
|
0…10 (bar)
|
26.7 (bar)
|
836E-DA1EN3D4
|
| 0…40 (bar)
|
0.21…41.38 (bar)
|
0…40 (bar)
|
106.7 (bar)
|
836E-DA1EQ3D4
|
| 0…100 (bar)
|
0.52…103.45 (bar)
|
0…100 (bar)
|
106.7 (bar)
|
836E-DA1ER3D4
|
| -15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DA1EU3D4
|
| Recommended Cordset: 2 m (6.5 ft) 4-pin DC Micro QD / M12 (straight)
|
889D-F4AC-2
|
| Recommended Cordset: 2 m (6.5 ft) 4-pin DC Micro QD / M12 (right angle)
|
889D-R4AC-2
|
|
|
| ⋆ Maximum working pressure (MWP) is the maximum pressure a switch can tolerate for an indefinite period of time. Over pressure limit is the maximum pressure a switch can tolerate for a short period of time without sustaining permanent damage. Burst pressure limit is the maximum pressure a switch can tolerate without sustaining permanent damage or leakage.
|
| Other cable lengths are available. Shielded cables may be required for some analog output applications. Refer to the On-Maschine Connectivity catalog for additional information.
|
| Process Connection
|
Pressure Range (psig)
|
Set Point Range (psig)
|
Reset Point Range (psig)
|
Maximum Working Pressure (psig)⋆
|
Cat. No.
|
| 1/4 inch NPT (female)
|
-15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DC1CC1D4
|
| 0…60
|
0.30…60
|
0…59.70
|
160.5
|
836E-DC1EL1D4
|
| 0…150
|
0.75…150
|
0…149.25
|
400.5
|
836E-DC1EN1D4
|
| 0…600
|
3.00…600
|
0…597.00
|
1600.5
|
836E-DC1EQ1D4
|
| 0…6,000
|
30…6000
|
0…5,970.00
|
6000
|
836E-DC1ER1D4
|
| 0…6,000
|
0.30…6000
|
0…5,970.00
|
6,000
|
836E-DC1EU1D4
|
| SAE 7/16-20 UNF (female)
|
-15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DC1CC2D4
|
| 0…60
|
0.30…60
|
0…59.70
|
160.5
|
836E-DC1EL2D4
|
| 0…150
|
0.75…150
|
0…149.25
|
400.5
|
836E-DC1EN2D4
|
| 0…600
|
3.00…600
|
0…597.00
|
1600.5
|
836E-DC1EQ2D4
|
| 0…400 (bar)
|
2.07…413.79 (bar)
|
0…400 (bar)
|
400 (bar)
|
836E-DC1ER2D4
|
| 0…6,000
|
0.30…6000
|
0…5,970.00
|
6,000
|
836E-DC1EU2D4
|
| G1/4 BSPP (female)
|
-15…15
|
-14.92…+15
|
-15.00…14.92
|
40.5
|
836E-DC1CC3D4
|
| 0…60
|
0.30…60
|
0…59.70
|
160.5
|
836E-DC1EL3D4
|
| 0…150
|
0.75…150
|
0…149.25
|
400.5
|
836E-DC1EN3D4
|
| 0…600
|
3.00…600
|
0…597.00
|
600
|
836E-DC1EQ3D4
|
| 0…100 (bar)
|
0.52…103.45 (bar)
|
0…100 (bar)
|
106.7 (bar)
|
836E-DC1ER3D4
|
| 0…400 (bar)
|
2.07…413.79 (bar)
|
0…400 (bar)
|
400 (bar)
|
836E-DC1EU3D4
|
| Recommended Cordset: 2 m (6.5 ft) 4-pin DC Micro QD / M12 (straight) §
|
889D-F4AC-2
|
| Recommended Cordset: 2 m (6.5 ft) 4-pin DC Micro QD / M12 (right angle) §
|
889D-R4AC-2
|
|
|
| ⋆ Maximum working pressure (MWP) is the maximum pressure a switch can tolerate for an indefinite period of time. Over pressure limit is the maximum pressure a switch can tolerate for a short period of time without sustaining permanent damage. Burst pressure limit is the maximum pressure a switch can tolerate without sustaining permanent damage or leakage.
|
| Analog output version may be set up to output dual PNP N.O./N.C.
|
| § Other cable lengths are available. Shielded cables may be required for some analog output applications. Refer to the On-Maschine Connectivity catalog for additional information.
|
| Description
|
Cat. No.
|
| 1/4 in. NPT (female) adaptor
|
836E-NP71
|
| 7/16-20 UNF (female) adaptor
|
836E-NP72
|
| G1/4 BSPP (female) adaptor
|
836E-NP73
|
| 1/4 in. NPT (male) adaptor
|
836E-NP74
|
| 7/16-20 UNF (male) adaptor
|
836E-NP75
|
| G1/4 BSPP (male) adaptor
|
836E-NP76
|
| Configuration Kit (includes converter cable and ReadWin 2000 software)
|
836E-NSR
|
|
|