Electronic Timed-Delay Unit
|
Description
The Electronic Timed-delay Unit (ETU) is used in applications that require an elapsed time to occur before allowing access to a hazardous area. The ETU uses an CU1 control unit timer to execute the timing sequence. Turning a nonremovable key initiates the timer. When the CU1 times out, its output energizes an internal solenoid, which then allows the removal of either one or two trapped keys.
The Single-key Timed delay Unit (STU) has one trapped key. After the CU1 preset time has expired, the single trapped key can be removed and used to continue the next sequence in allowing access to the hazard. The single key must be returned to the STU and trapped to allow the nonremovable key to re-initiate the hazard.
The Dual-key Timed delay Unit (DTU) has two trapped keys. After the CU1 preset time has expired, both keys can be removed and used to continue the next sequences in allowing access to the hazard. Both keys must be returned to the DTU and trapped to allow the nonremovable key re-initiate the hazard.
Features
- Timed-delay output up to 40 minutes
- Single key or dual key
- 316L stainless steel keys
- Category 1 Stop
- Replaceable code barrel assembly
The Prosafe Advantage
|
Stainless steel construction. |
Specifications
| Safety Ratings | |
| Standards | IEC/EN60204-1,EN1088, IEC/EN60947-5-1, ISO13849-1, ISO12100-1&2, ISO14119, GS-ET-19, AS4024.1 |
| Category | Cat. 1 per EN 954-1 (ISO 13849-1) |
| Certifications | CE Marked for all applicable directives and BG |
| Operating Characteristics | |
| Electrical Life | 100,000 operations |
| Mechanical Life | 100,000 operations |
| Solenoid Voltage | 24V DC, 110V AC, and 230V AC |
| Time Delay | 0.1 s…30 min |
| Environmental & Physical Characteristics | |
| Operating Temperature [C (F)] | 0…40 ° (32…104 °) |
| Relative Humidity | 95% |
| Shear Force to Key | 15.1 kN (3398 lbs), max. |
| Torque to Key | 14 Nm (124 lbin), max. |
| Material | Trapped key components: 316L stainless steel Face plate: 316L stainless steel Optional box: ABS plastic or stainless steel |
Product Selection
| Type | Solenoid Voltage | Contact Set 1 | Contact Set 2 | Cat. No. |
| Single key out Panel mounted |
24V DC | 3 N.O. 40 A | 1 N.O. 20 A | 440T-MSTUE10¬ |
| 2 N.O. 20 A | 1 N.C. 20 A | 440T-MSTUE11¬ | ||
| 110V AC | 3 N.O. 40 A | 1 N.O. 20 A | 440T-MSTUE20¬ | |
| 2 N.O. 20 A | 1 N.C. 20 A | 440T-MSTUE22¬ | ||
| 230V AC | 3 N.O. 40 A | 1 N.O. 20 A | 440T-MSTUE30¬ | |
| 2 N.O. 20 A | 1 N.C. 20 A | 440T-MSTUE33¬ | ||
| Dual key out Panel mounted |
24V DC | 3 N.O. 40 A | 1 N.O. 20 A | 440T-MDTUE10¬ ¬ |
| 2 N.O. 20 A | 1 N.C. 20 A | 440T-MDTUE11¬ ¬ | ||
| 110V AC | 3 N.O. 40 A | 1 N.O. 20 A | 440T-MDTUE20¬ ¬ | |
| 2 N.O. 20 A | 1 N.C. 20 A | 440T-MDTUE22¬ ¬ | ||
| 230V AC | 3 N.O. 40 A | 1 N.O. 20 A | 440T-MDTUE30¬ ¬ | |
| 2 N.O. 20 A | 1 N.C. 20 A | 440T-MDTUE33¬ ¬ | ||
| ¬ Substitute the desired primary code for this symbol (key not included). See Key Coding for code selection. | ||||
Accessories
| Description | Additional Information | Cat. No. |
| Stainless steel key | Accessories | 440T-AKEYE10¬ |
| Stainless steel replacement code barrel with dust cap | 440T-ASCBE14¬ | |
| Stainless steel weatherproof replacement dust cap | 440T-ASFC10¬ | |
| Optional plastic enclosure | For use with 20 A units | 440T-AIPB20 |
| For use with 40 A units | 440T-AIPB23 | |
| Optional stainless steel enclosure | For use with all units | 440T-AIPB46 |
| ¬ Substitute the desired primary code for this symbol (key not included). See Key Coding for code selection. | ||
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|