Rotary Switch

Click to enlarge - 440T-MR#SE1#_Product


Description

The rotary switches are used for electrical isolation of machinery to improve safe access and also as teach boxes in robot cells. Once the power has been turned off, the key can then be withdrawn and used in the next sequence of operation such as unlocking an access hatch or allowing valves to be operated.

The rotary switch can either be mounted in a panel or purchased in an enclosure. The rotary switch is available with 4 poles, either 4 N.O. or 2 N.C. and 2 N.O. The 100 A 4 N.O. switch has 3 contacts rated at 100 A and 1 contact rated at 20 A.


Features


The Prosafe Advantage

Click to enlarge - 440T (Advantage)_Detail_GS      Stainless steel
construction.

Specifications

Safety Ratings
Standards EN1088, IEC/EN60204-1, IEC/EN60947-5-1, ISO12100-1&2, ISO14119, GS-ET-19, AS4024.1, UL508, CSA 22.2
Category Cat. 1 per EN 954-1 (ISO 13849-1)
Suitable for Cat. 2, 3, and 4 systems
Certifications CE Marked for all applicable directives, BG, cULus on contact block; C-Tick not required
Operating Characteristics
Conduit Entry 4 x M20 (RKS only)
Mechanical Life 100,000 operations
Finger Protection DIN 57106/VDE 0106 T.100
Environmental Characteristics
Operating Temperature [C (F)] -10…+40 ° (14…104 °)
Relative Humidity 95%
Physical Characteristics
Shear Force to Key 15.1 k•N (3398 lbs), max.
Torque to Key 14 N•m (124 lb•in), max.
 

Weight [g (lb)] RPSE 10, 11, 12, 13, 20: 500 (1.1) 14, 16: 1000 (2.2)
RKSE 10, 11, 12, 13: 850 (1.9) 14, 16: 1250 (2.8)
Electrical Life 100,000 operations
Climatic Test Constant to DIN IEC 68 Part 2-3
Variable to DIN IEC 68 Part 2-30
Ambient Temperature, Operation Encased -25…40 °C (10…104 °F)
(Ui) Rated Insulation Voltage 690V
(Uimp) Rated Impulse withstand Voltage 6 kV
S3 Intermittent Rating Duty Factor (VDE 0530, Part 1) 60/40/25% = 1, 3/1, 6/2 xlu
Last two digits of Cat. No. (See Product Selection table) 10
11
16
12 13 14
Rated Uninterrupted Current (Iu) IEC/EN/VDE 20A 32A 63A 100A
UL/CSA 16A 30A 60A 100A
Rated Operational Voltage (Ue) IEC/EN/VDE 690V 690V 690V 1000V
UL/CSA 600V 600V 600V 600V
Main Switch Isolation Voltage, Max. 750V 750V 750V 1000V
Rated Operational Current (Ie) AC-21A IEC/EN/VDE 20A 32A 63A 100A
AC-1 SEV 20A 32A 63A 100A
Rated Operational Power at 50/60 Hz (AC-23A IEC/EN/VDE) 3-phase 220…240V 4 kW 5.5 kW 15 kW 22 kW
3-pole 380…440V 7.5 kW 11 kW 22 kW 37 kW
500…690V 7.5 kW 11 kW 22 kW 37 kW
Rated Operational Power at 50/60 Hz (AC-3A IEC/EN/VDE) 3-phase 220…240V 3 kW 4 kW 11 kW 22 kW
3-pole 380…440V 5.5 kW 7.5 kW 18.5 kW 30 kW
500…690V 5.5 kW 7.5 kW 18.5 kW 30 kW
DOL Rating (UL/CSA) 3-phase 140V 1 HP 2 HP 5 HP 10 HP
3-pole 240V 2 HP 5 HP 15 HP 25 HP
480V 5 HP 10 HP 30 HP 30 HP
600V 5 HP 10 HP 40 HP 30 HP
Rated Breaking Capacity AC-23/AC-3 220…240V 250A 330A 500A 600A
Motor Switch 380…440V 250A 330A 500A 600A
500…690V 150A 220A 270A 300A
Fuse Rating (GI) 25 A, max. 35 A, max. 63/50 A, max. 100 A, max.
Rated Fuse Short Circuit Current 15 kA 15 kA 15/20 kA 25 kA
Terminal Cross Section 1…10 4…16 2.5…3.5
mm2 single/multiple wire
Conductor Size, mm2 min…max 0.75 …6 2.5…10 1.5…2.5
(stranded) with sleeve
8 AWG 6 AWG 2 AWG
 

Product Selection

Type Contact Type Current Accuracy Cat. No.
Click to enlarge - 440T-MRKSE10_Table Row Head 4 N.O. 20 A 440T-MRKSE10⋆ 
2 N.O. & 2 N.C. 20 A 440T-MRKSE11⋆ 
4 N.O. 32 A 440T-MRKSE12⋆ 
4 N.O. 63 A 440T-MRKSE13⋆ 
3 N.O. & 1 N.O. 3 N.O. 100 A and 1 N.O. 20 A 440T-MRKSE14⋆ 
Enclosure Mounted (RKS only) 8 N.O. 20 A 440T-MRKSE16⋆ 
Mild Steel Enclosure Mounted (RKS only) 3 N.O. + Neutral 200 A 440T-MRKSE21⋆ 
3 N.O. 400 A 440T-MRKSE22⋆ 
Click to enlarge - 440T-MRPSE1#_Table Row Head 4 N.O. 20 A 440T-MRPSE10⋆ 
2 N.O. & 2 N.C. 20 A 440T-MRPSE11⋆ 
4 N.O. 32 A 440T-MRPSE12⋆ 
4 N.O. 63 A 440T-MRPSE13⋆ 
3 N.O. & 1 N.O. 3 N.O. 100 A and 1 N.O. 20 A 440T-MRPSE14⋆ 
8 N.O. 20 A 440T-MRPSE16⋆ 
3 N.O. & 3 N.C. 20 A 440T-MRPSE18⋆ 
Panel Mounted 4 N.O. 40 A 440T-MRPSE20⋆ 
 
⋆ Substitute the desired primary code for this symbol (key not included). See Key Coding.

  Type Number of Keys Contact Type Current Accuracy Cat. No.
Isolator on First Key Out
Click to enlarge - LargePanel4Locks_4c Dual key isolator 2 keys out 4 N.O. 20 A 440T-MMRSE10⋆ ⋆ 
2 N.O. & 2 N.C. 20 A 440T-MMRSE11⋆ ⋆ 
4 N.O. 32 A 440T-MMRSE12⋆ ⋆ 
4 N.O. 63 A 440T-MMRSE13⋆ ⋆ 
Triple key isolator 3 keys out 4 N.O. 20 A 440T-MMRSE20⋆ ⋆ ⋆ 
2 N.O. & 2 N.C. 20 A 440T-MMRSE21⋆ ⋆ ⋆ 
4 N.O. 32 A 440T-MMRSE22⋆ ⋆ ⋆ 
4 N.O. 63 A 440T-MMRSE23⋆ ⋆ ⋆ 
Quad key isolator 4 keys out 4 N.O. 20 A 440T-MMRSE30⋆ ⋆ ⋆ ⋆ 
2 N.O. & 2 N.C. 20 A 440T-MMRSE31⋆ ⋆ ⋆ ⋆ 
4 N.O. 32 A 440T-MMRSE32⋆ ⋆ ⋆ ⋆ 
4 N.O. 63 A 440T-MMRSE33⋆ ⋆ ⋆ ⋆ 
Click to enlarge - 440T-MMRXE10_product Dual key exchange isolator 1 key in/ 1 key out 4 N.O. 20 A 440T-MMRXE10⋆ Ä
2 N.O. & 2 N.C. 20 A 440T-MMRXE11⋆ Ä
4 N.O. 32 A 440T-MMRXE12⋆ Ä
4 N.O. 63 A 440T-MMRXE13⋆ Ä
Triple key exchange isolator 1 key in/ 2 key out 4 N.O. 20 A 440T-MMRXE20⋆ ÄÄ
2 N.O. & 2 N.C. 20 A 440T-MMRXE21⋆ ÄÄ
4 N.O. 32 A 440T-MMRXE22⋆ ÄÄ
4 N.O. 63 A 440T-MMRXE23⋆ ÄÄ
Quad key exchange isolator 1 key in/ 3 key out 4 N.O. 20 A 440T-MMRXE30⋆ ÄÄÄ
2 N.O. & 2 N.C. 20 A 440T-MMRXE31⋆ ÄÄÄ
4 N.O. 32 A 440T-MMRXE32⋆ ÄÄÄ
4 N.O. 63 A 440T-MMRXE33⋆ ÄÄÄ
    
⋆ Substitute the desired primary code for this symbol (key not included). See Key Coding.
Ä Substitute the desired secondary code for this symbol (key included). See Key Coding.

Accessories

Description Additional Information Cat. No.
Stainless steel key Accessories 440T-AKEYE10⋆ 
Stainless steel replacement code barrel with dust cap 440T-ASCBE14⋆ 
Stainless steel replacement code barrel for 100 A unit rotary switch 440T-ASCBE11⋆ 
Stainless steel weatherproof replacement dust cap 440T-ASFC10⋆ 
Cable grip, M20 conduit, accommodates cable diameter 7…10.5 mm (0.27…0.41 in.) Conduit Accessories 440A-A09028
Adaptor, conduit, M20 to 1/2 inch NPT, plastic 440A-A09042
Supplemental Contact Block, 20 A, 1 N.O. Late Make, Early Break 1 N.C. Auxiliary For use with RPSE12, RPSE20 (maximum 1 per switch) 440T-AACA10
Supplemental Contact Block, 20 A, 2 N.O. Late Make, Early Break For use with RPSE12, RPSE20 (maximum 1 per switch) 440T-AACA11
Supplemental Contact Block, 20 A, 1 N.O., 1 N.C. For use with RPSE13 & 14 440T-AACA20
Supplemental Contact Block, 20 A, 2 N.O. For use with RPSE13 & 14 440T-AACA21
ABS plastic enclosure For use with dual key, and dual key exchange, isolators 440T-AIPB10
Stainless steel enclosure (240x180x150 mm) For use with >20 A RPSE units (not including RPSE21 or 22) 440T-AIPB25
Stainless steel enclosure (150x150x80 mm) For use with RPSE10 & 11 440T-AIPB26
Optional ABS plastic enclosure For use with triple/quad key, and triple/quad key exchange, isolators 440T-AIPB50
Optional stainless steel enclosure For use with triple/quad key, and triple/quad key exchange, isolators 440T-AIPB55
 
⋆ Substitute the desired primary code for this symbol (key not included). See Key Coding.

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

MRKSE10 and MRKSE11

Click to enlarge - 440T-MRKSE10_dims_4c


MRKSE12 and MRKSE13

Click to enlarge - 440T-RKSE1#(12-13)_Dims


MMRSE10

Click to enlarge - 440T-MMRSE10_dims_4c


MMRSE20

Click to enlarge - 440T-MMRSE20_dims_4c


Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

MRKSE14

Click to enlarge - 440T-RKSE1#(14)_Dims


MRKSE16

Click to enlarge - 440T-RKSE1#(16)_Dims


MRPSE10 and 11

Click to enlarge - 440T-RPSE1#(10-11)_Dims


MRPSE 12, 13, 14 and 20

Click to enlarge - 440T-RPSE1#(12-13-14-20)_Dims


MMRXE10 and MMRXE11

Click to enlarge - 440T-MMRXE10_dims


MMRXE30

Click to enlarge - 440T-MMRXE30_dims_4C


MRKSE22

Click to enlarge - 440T-MRKSE22_dims_4C


MRPSE16

Click to enlarge - 440T-RPSE1#(16)_Dims

Typical Wiring

Diagrams Shown with Key Free

Click to enlarge - 440T-R#SE1#_Wiring