| Safety Ratings
|
| Standards
|
EN1088, IEC/EN60204-1, IEC/EN60947-5-1, ISO12100-1&2, ISO14119, GS-ET-19, AS4024.1, UL508, CSA 22.2
|
| Category
|
Cat. 1 per EN 954-1 (ISO 13849-1) Suitable for Cat. 2, 3, and 4 systems
|
| Certifications
|
CE Marked for all applicable directives, BG, cULus on contact block; C-Tick not required
|
| Operating Characteristics
|
| Conduit Entry
|
4 x M20 (RKS only)
|
| Mechanical Life
|
100,000 operations
|
| Finger Protection
|
DIN 57106/VDE 0106 T.100
|
| Environmental Characteristics
|
| Operating Temperature [C (F)]
|
-10…+40 ° (14…104 °)
|
| Relative Humidity
|
95%
|
| Physical Characteristics
|
| Shear Force to Key
|
15.1 kN (3398 lbs), max.
|
| Torque to Key
|
14 Nm (124 lbin), max.
|
|
|
| Weight [g (lb)]
|
RPSE
|
10, 11, 12, 13, 20:
|
500 (1.1)
|
14, 16:
|
1000 (2.2)
|
| RKSE
|
10, 11, 12, 13:
|
850 (1.9)
|
14, 16:
|
1250 (2.8)
|
| Electrical Life
|
100,000 operations
|
| Climatic Test
|
Constant to DIN IEC 68 Part 2-3 Variable to DIN IEC 68 Part 2-30
|
| Ambient Temperature, Operation
|
Encased -25…40 °C (10…104 °F)
|
| (Ui) Rated Insulation Voltage
|
690V
|
| (Uimp) Rated Impulse withstand Voltage
|
6 kV
|
| S3 Intermittent Rating Duty Factor (VDE 0530, Part 1)
|
60/40/25% = 1, 3/1, 6/2 xlu
|
| Last two digits of Cat. No. (See Product Selection table)
|
10 11 16
|
12
|
13
|
14
|
| Rated Uninterrupted Current (Iu)
|
IEC/EN/VDE
|
20A
|
32A
|
63A
|
100A
|
| UL/CSA
|
16A
|
30A
|
60A
|
100A
|
| Rated Operational Voltage (Ue)
|
IEC/EN/VDE
|
690V
|
690V
|
690V
|
1000V
|
| UL/CSA
|
600V
|
600V
|
600V
|
600V
|
| Main Switch Isolation Voltage, Max.
|
750V
|
750V
|
750V
|
1000V
|
| Rated Operational Current (Ie)
|
AC-21A IEC/EN/VDE
|
20A
|
32A
|
63A
|
100A
|
| AC-1 SEV
|
20A
|
32A
|
63A
|
100A
|
| Rated Operational Power at 50/60 Hz (AC-23A IEC/EN/VDE)
|
3-phase 220…240V
|
4 kW
|
5.5 kW
|
15 kW
|
22 kW
|
| 3-pole 380…440V
|
7.5 kW
|
11 kW
|
22 kW
|
37 kW
|
| 500…690V
|
7.5 kW
|
11 kW
|
22 kW
|
37 kW
|
| Rated Operational Power at 50/60 Hz (AC-3A IEC/EN/VDE)
|
3-phase 220…240V
|
3 kW
|
4 kW
|
11 kW
|
22 kW
|
| 3-pole 380…440V
|
5.5 kW
|
7.5 kW
|
18.5 kW
|
30 kW
|
| 500…690V
|
5.5 kW
|
7.5 kW
|
18.5 kW
|
30 kW
|
| DOL Rating (UL/CSA)
|
3-phase 140V
|
1 HP
|
2 HP
|
5 HP
|
10 HP
|
| 3-pole 240V
|
2 HP
|
5 HP
|
15 HP
|
25 HP
|
| 480V
|
5 HP
|
10 HP
|
30 HP
|
30 HP
|
| 600V
|
5 HP
|
10 HP
|
40 HP
|
30 HP
|
| Rated Breaking Capacity
|
AC-23/AC-3 220…240V
|
250A
|
330A
|
500A
|
600A
|
| Motor Switch 380…440V
|
250A
|
330A
|
500A
|
600A
|
| 500…690V
|
150A
|
220A
|
270A
|
300A
|
| Fuse Rating (GI)
|
25 A, max.
|
35 A, max.
|
63/50 A, max.
|
100 A, max.
|
| Rated Fuse Short Circuit Current
|
15 kA
|
15 kA
|
15/20 kA
|
25 kA
|
| Terminal Cross Section
|
1…10
|
4…16
|
2.5…3.5
|
| mm2 single/multiple wire
|
| Conductor Size, mm2 min…max
|
0.75 …6
|
2.5…10
|
1.5…2.5
|
| (stranded) with sleeve
|
| 8 AWG
|
6 AWG
|
2 AWG
|
|
|
| Type
|
Contact Type
|
Current Accuracy
|
Cat. No.
|
|
4 N.O.
|
20 A
|
440T-MRKSE10¬
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MRKSE11¬
|
| 4 N.O.
|
32 A
|
440T-MRKSE12¬
|
| 4 N.O.
|
63 A
|
440T-MRKSE13¬
|
| 3 N.O. & 1 N.O.
|
3 N.O. 100 A and 1 N.O. 20 A
|
440T-MRKSE14¬
|
| Enclosure Mounted (RKS only)
|
8 N.O.
|
20 A
|
440T-MRKSE16¬
|
| Mild Steel Enclosure Mounted (RKS only)
|
3 N.O. + Neutral
|
200 A
|
440T-MRKSE21¬
|
| 3 N.O.
|
400 A
|
440T-MRKSE22¬
|
|
4 N.O.
|
20 A
|
440T-MRPSE10¬
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MRPSE11¬
|
| 4 N.O.
|
32 A
|
440T-MRPSE12¬
|
| 4 N.O.
|
63 A
|
440T-MRPSE13¬
|
| 3 N.O. & 1 N.O.
|
3 N.O. 100 A and 1 N.O. 20 A
|
440T-MRPSE14¬
|
| 8 N.O.
|
20 A
|
440T-MRPSE16¬
|
| 3 N.O. & 3 N.C.
|
20 A
|
440T-MRPSE18¬
|
| Panel Mounted
|
4 N.O.
|
40 A
|
440T-MRPSE20¬
|
|
|
| ¬ Substitute the desired primary code for this symbol (key not included). See Key Coding.
|
|
|
Type
|
Number of Keys
|
Contact Type
|
Current Accuracy
|
Cat. No.
|
| Isolator on First Key Out
|
|
Dual key isolator
|
2 keys out
|
4 N.O.
|
20 A
|
440T-MMRSE10¬ ¬
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MMRSE11¬ ¬
|
| 4 N.O.
|
32 A
|
440T-MMRSE12¬ ¬
|
| 4 N.O.
|
63 A
|
440T-MMRSE13¬ ¬
|
| Triple key isolator
|
3 keys out
|
4 N.O.
|
20 A
|
440T-MMRSE20¬ ¬ ¬
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MMRSE21¬ ¬ ¬
|
| 4 N.O.
|
32 A
|
440T-MMRSE22¬ ¬ ¬
|
| 4 N.O.
|
63 A
|
440T-MMRSE23¬ ¬ ¬
|
| Quad key isolator
|
4 keys out
|
4 N.O.
|
20 A
|
440T-MMRSE30¬ ¬ ¬ ¬
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MMRSE31¬ ¬ ¬ ¬
|
| 4 N.O.
|
32 A
|
440T-MMRSE32¬ ¬ ¬ ¬
|
| 4 N.O.
|
63 A
|
440T-MMRSE33¬ ¬ ¬ ¬
|
|
Dual key exchange isolator
|
1 key in/ 1 key out
|
4 N.O.
|
20 A
|
440T-MMRXE10¬ Ä
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MMRXE11¬ Ä
|
| 4 N.O.
|
32 A
|
440T-MMRXE12¬ Ä
|
| 4 N.O.
|
63 A
|
440T-MMRXE13¬ Ä
|
| Triple key exchange isolator
|
1 key in/ 2 key out
|
4 N.O.
|
20 A
|
440T-MMRXE20¬ ÄÄ
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MMRXE21¬ ÄÄ
|
| 4 N.O.
|
32 A
|
440T-MMRXE22¬ ÄÄ
|
| 4 N.O.
|
63 A
|
440T-MMRXE23¬ ÄÄ
|
| Quad key exchange isolator
|
1 key in/ 3 key out
|
4 N.O.
|
20 A
|
440T-MMRXE30¬ ÄÄÄ
|
| 2 N.O. & 2 N.C.
|
20 A
|
440T-MMRXE31¬ ÄÄÄ
|
| 4 N.O.
|
32 A
|
440T-MMRXE32¬ ÄÄÄ
|
| 4 N.O.
|
63 A
|
440T-MMRXE33¬ ÄÄÄ
|
|
|
| ¬ Substitute the desired primary code for this symbol (key not included). See Key Coding.
|
| Ä Substitute the desired secondary code for this symbol (key included). See Key Coding.
|
| Description
|
Additional Information
|
Cat. No.
|
| Stainless steel key
|
Accessories
|
440T-AKEYE10¬
|
| Stainless steel replacement code barrel with dust cap
|
440T-ASCBE14¬
|
| Stainless steel replacement code barrel for 100 A unit rotary switch
|
440T-ASCBE11¬
|
| Stainless steel weatherproof replacement dust cap
|
440T-ASFC10¬
|
| Cable grip, M20 conduit, accommodates cable diameter 7…10.5 mm (0.27…0.41 in.)
|
Conduit Accessories
|
440A-A09028
|
| Adaptor, conduit, M20 to 1/2 inch NPT, plastic
|
440A-A09042
|
| Supplemental Contact Block, 20 A, 1 N.O. Late Make, Early Break 1 N.C. Auxiliary
|
For use with RPSE12, RPSE20 (maximum 1 per switch)
|
440T-AACA10
|
| Supplemental Contact Block, 20 A, 2 N.O. Late Make, Early Break
|
For use with RPSE12, RPSE20 (maximum 1 per switch)
|
440T-AACA11
|
| Supplemental Contact Block, 20 A, 1 N.O., 1 N.C.
|
For use with RPSE13 & 14
|
440T-AACA20
|
| Supplemental Contact Block, 20 A, 2 N.O.
|
For use with RPSE13 & 14
|
440T-AACA21
|
| ABS plastic enclosure
|
For use with dual key, and dual key exchange, isolators
|
440T-AIPB10
|
| Stainless steel enclosure (240x180x150 mm)
|
For use with >20 A RPSE units (not including RPSE21 or 22)
|
440T-AIPB25
|
| Stainless steel enclosure (150x150x80 mm)
|
For use with RPSE10 & 11
|
440T-AIPB26
|
| Optional ABS plastic enclosure
|
For use with triple/quad key, and triple/quad key exchange, isolators
|
440T-AIPB50
|
| Optional stainless steel enclosure
|
For use with triple/quad key, and triple/quad key exchange, isolators
|
440T-AIPB55
|
|
|
| ¬ Substitute the desired primary code for this symbol (key not included). See Key Coding.
|