440P—15 mm Plastic

Click to enlarge - 440P-M18001_Product    Click to enlarge - 440P-M18002_Product
Imp 1 Imp 2

Description

The Imp offers safety switch performance of bigger units in the most compact case available. Designed with two mounting hole options and a choice of actuator positions, the Imp will fit in most confined spaces.

Features


Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, NFPA 79, EN 1088, ISO 14119, IEC/ EN 60947-5-1, ANSI B11.19, AS 4024.1
Safety Classification Cat. 1 Device per EN954-1 Dual channel limit switch suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
B10d: > 2 x 106 operations at min. load
PFHD: > 3 x10-7
MTTFd: > 385 years
Dual channel limit switch may be suitable for performance levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives and CSA NRTL/C
Outputs
Safety Contacts T  1 N.C. positive break
Auxiliary Contacts 1 N.O.
Thermal CurrentIlth 10 A (Ith)
Rated Insulation Voltage (Ui) 500V
Switching Current @ Voltage, Min. 25 mA @ 5V DC
Utilization Category
AC-15 (Ue) 500V 250V 100V
  (le) 1 A 2 A 5 A
DC (Ue) 250V 24V  
  (le) 0.5 A 2 A  
Operating Characteristics
Actuation Speed, Max. 160 mm (6.29 in.)/s
Actuation Speed, Min. 100 mm (3.93 in.)/min
Actuator Travel, Max. 5 mm (0.20 in.)
Actuation Frequency, Max. 2 cycles/s
Mechanical Life 10,000,000 operations
Electrical Life 1,000,000 operations
Mechanical Life 10,000,000 operations
Environmental
Enclosure Type Rating IP30
Operating Temperature [C (F)] -25…80° (-13…176°)
Pollution Degree 3
Physical Characteristics
Housing Material UL Approved glass-filled PBT
Actuator Material Stainless steel
Mounting 2 x M4 front or 2 x M3 top
Vibration 10…55 Hz
Shock 11 ms @ 30 g
Conduit Entry 3x break-outs
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years
T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started.

Product Selection

Actuator Type Contact Contact Action Conduit Type Cat. No.
Click to enlarge - ContactOpeningKey
Top push roller Slow break before make 1 N.C. & 1 N.O. Click to enlarge - 440P-M1800#_COC 3 x breakouts Imp 1 (roller parallel to switch front) 440P-M18001
Top push cross roller Imp 2 (roller perpendicular to switch front) 440P-M18002
 

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440P-M1800#_Dims

Wiring Diagrams

Click to enlarge - 440P-M1800#_Connections