802T Plug-In Safety Limit Switches
|
Description
The 802T Direct Opening Action limit switches have been designed for use in control reliable applications and safety applications per ISO 14119. These limit switches utilize the same mounting dimensions as other NEMA style limit switches. The rugged metal construction and plug-in body are designed for use in harsh industrial environments.
Direct Opening Action allows the normally closed contacts to open when the limit switch is actuated. This opening will occur even in the event of a contact weld condition, up to 10 Newtons.
|
ATTENTION: To ensure that the normally closed (safety) contacts open, the limit switch actuator must be displaced beyond the point of Direct Opening Action (see specifications). |
Features
- Direct opening action
- Snap acting contacts
- Rugged metal construction
- Long life and reliability
- Plug-in design
- NEMA 12, 13, 4, 6P/IP67 sealing
Typical Applications
- Machine guards
- Access gates and doors
- Cranes or hoists
- Transfer stations
- Indexing tables
- Robotic cells
Specifications
| Safety Ratings | |||||
| Standards | EN 954-1, ISO 13849-1, IEC/EN 60204-1, NFPA 79, EN 1088, ISO 14119, IEC/ EN 60947-5-1, ANSI B11.19, AS 4024.1 | ||||
| Safety Classification | Cat. 1 Device per EN 954-1 Dual channel limit switch suitable for Cat. 3 or 4 systems | ||||
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/Safety/ |
B10d = > 2 x 106 operations at min. load PFHD = > 3 x10-7 MTTFd = > 385 years Dual channel limit switch may be suitable for Performace levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics |
||||
| Certifications | CE Marked for all applicable directives, cULus Listed, and TÜV for 2- and 4-circuit models | ||||
| Outputs | |||||
| Safety Contacts T | 1 N.C. snap acting or 2 N.C. snap acting | ||||
| Auxiliary Contacts | 1 N.O. snap acting or 2 N.O. snap acting | ||||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | 300V AC or 600V AC | ||||
| Switching Current @ Voltage, Min. | — | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3.0 A | 6.0 A | |
| N600/DC-13 | (Ue) | 600V | 500V | 250V | 125V |
| (le) | 0.4 A | 0.55 A | 1.1 A | 2.2 A | |
| Operating Characteristics | |||||
| Actuation Speed, Max. | 200 ft/min varies with applied loading and actuation method¬ | ||||
| Actuation Speed, Min. | 200 ft/min varies with applied loading and actuation method¬ | ||||
| Actuation Frequency, Max. | 8000 operations per hour | ||||
| Mechanical Life | 20 million cycles | ||||
| Environmental | |||||
| Enclosure Type Rating | NEMA 4, 6P, 12, 13 and IP65/67 | ||||
| Operating Temperature [C (F)] | -18…+110° (0…+230°) | ||||
| Pollution Degree | 3 | ||||
| Physical Characteristics | |||||
| Housing Material | Die-cast alloy | ||||
| Actuator Material | Various metals or plastics | ||||
| Mounting | 2 #10 equal length fasteners | ||||
| Vibration | Contact fragility (10…2000 Hz @ 0.06 inch peak-to-peak) | ||||
| Shock | Contact fragility (25 Gn 3 pulses per axis) | ||||
| Conduit Entry | 1/2 inch NPT or M20 | ||||
| Color | Grey | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||
| AC Contact Rating (Maximum per Pole, 50 or 60Hz, 2 Circuits) |
||||||
| NEMA Rating Designation |
Max Voltage |
A | Continuous Carrying Current |
VA | ||
| Make | Break | Make | Break | |||
| A600 | 120 | 60 | 6.00 | 10 | 7200 | 720 |
| 240 | 30 | 3.00 | 10 | 7200 | 720 | |
| AC-15 | 480 | 15 | 1.50 | 10 | 7200 | 720 |
| 600 | 12 | 1.20 | 10 | 7200 | 720 | |
| AC Contact Rating (Maximum per Pole, 50 or 60Hz, 4 Circuits) |
||||||
| NEMA Rating Designation |
Max Voltage |
A | Continuous Carrying Current |
VA | ||
| Make | Break | Make | Break | |||
| A300 | 120 | 60 | 6.00 | 10 | 7200 | 720 |
| 240 | 30 | 3.00 | 10 | 7200 | 720 | |
| DC Contact Rating (Maximum per Pole) | ||||||
| NEMA Rating Designation | Max Voltage | A | Continuous Carrying Current | VA | ||
| Make | Break | Make | Break | |||
| Q300 | 250 | 0.27 | 0.27 | 2.5 | 69 | 69 |
| 125 | 0.55 | 0.55 | 2.5 | 69 | 69 | |
| DC 13 | ||||||
Low Voltage DC
24V DC @ 1.1 Amps resistive load
Range of Operation
|
|
|
|
|
||||
| Lever Type Spring Return |
Top Push Roller Spring Return |
Side Push Vertical Roller Spring Return |
Side Push Horizontal Roller Spring Return |
Product Selection
Modifications and Typical Levers—Modifications.
Typical Example of a Dual Channel Safety Application
|
|
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
||
| Plug-In Switch | ||
|
||
| Lever Type Head | Top Push Roller Head | Side Push Roller Head |
Modifications
Metric Conduit Entry
To order a limit switch with a 20 mm conduit entry, add the suffix S6 to the cat. no. Example: 802T-APDS6.
Pre-wired Cable
To order a factory-installed pre-wired type STOOW-A cable (5-conductor), add the suffix Y plus the number of feet required. The standard cable length is 1.52 m (5 ft). Extended cable lengths are available in multiples of 1.22 m (4 ft) only.
Example: To order a limit switch with a factory-installed 1.52 m (5 ft) cable, the cat. no. would become 802T-APDY5. To order a limit switch with a factory-installed 2.44 m (8 ft) cable, the cat. no. would become 802T-APDY8.
Mini-Style Quick-Disconnect
To order an 802T pre-wired limit switch with a 5-pin (2 circuit) or 9-pin (4 circuit) mini connector, add the suffix J1 or J9 depending on desired wiring (J9 wiring not available for 4-circuit models) to the cat. no. Example: 802TAPDJ1.
| 5-Pin Mini-Type Receptacle (2 circuit) |
|
| 9-Pin Mini-Type Receptacle (4 circuit) |
|
Micro-Style Quick-Disconnect
Micro quick-disconnects are available with a 5-pin 2-keyway AC or 5-pin single keyway DC. To order a limit switch with a AC micro quick-disconnect, add the suffix R5 to the cat. no. To order a limit switch with a DC micro quick-disconnect, add the suffix D5 to the cat. no. Example: 802TAPDR5 and 802TAPDD5.
|
Levers