NEMA Style Safety Limit Switches

Catalogs > Safety Products Catalog > Safety Switches > Safety Limit Switches > NEMA Style Safety Limit Switches > 802T Plug-In Safety Limit Switches

802T Plug-In Safety Limit Switches

Introduction Specifications Range of Operation Product Selection
Typical Example of a Dual Channel Safety Application Approximate Dimensions Modifications Levers
Specifications

Safety Ratings
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, NFPA 79, EN 1088, ISO 14119, IEC/ EN 60947-5-1, ANSI B11.19, AS 4024.1
Safety Classification Cat. 1 Device per EN 954-1 Dual channel limit switch suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/Safety/
B10d = > 2 x 106 operations at min. load
PFHD = > 3 x10-7
MTTFd = > 385 years
Dual channel limit switch may be suitable for Performace levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives, cULus Listed, and TÜV for 2- and 4-circuit models
Outputs
Safety Contacts T  1 N.C. snap acting or 2 N.C. snap acting
Auxiliary Contacts 1 N.O. snap acting or 2 N.O. snap acting
Thermal CurrentIlth 10 A
Rated Insulation Voltage 300V AC or 600V AC
Switching Current @ Voltage, Min.
Utilization Category
A600/AC-15 (Ue) 600V 500V 240V 120V
  (le) 1.2 A 1.4 A 3.0 A 6.0 A
N600/DC-13 (Ue) 600V 500V 250V 125V
  (le) 0.4 A 0.55 A 1.1 A 2.2 A
Operating Characteristics
Actuation Speed, Max. 200 ft/min varies with applied loading and actuation method¬ 
Actuation Speed, Min. 200 ft/min varies with applied loading and actuation method¬ 
Actuation Frequency, Max. 8000 operations per hour
Mechanical Life 20 million cycles
Environmental
Enclosure Type Rating NEMA 4, 6P, 12, 13 and IP65/67
Operating Temperature [C (F)] -18…+110° (0…+230°)
Pollution Degree 3
Physical Characteristics
Housing Material Die-cast alloy
Actuator Material Various metals or plastics
Mounting 2 #10 equal length fasteners
Vibration Contact fragility (10…2000 Hz @ 0.06 inch peak-to-peak)
Shock Contact fragility (25 Gn 3 pulses per axis)
Conduit Entry 1/2 inch NPT or M20
Color Grey
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years
T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started.

AC Contact Rating (Maximum per Pole, 50 or 60Hz,
2 Circuits)
NEMA
Rating
Designation
Max
Voltage
A Continuous
Carrying
Current
VA
Make Break Make Break
A600 120 60 6.00 10 7200 720
240 30 3.00 10 7200 720
AC-15 480 15 1.50 10 7200 720
600 12 1.20 10 7200 720
  

AC Contact Rating (Maximum per Pole, 50 or 60Hz,
4 Circuits)
NEMA
Rating
Designation
Max
Voltage
A Continuous
Carrying
Current
VA
Make Break Make Break
A300 120 60 6.00 10 7200 720
240 30 3.00 10 7200 720
  

DC Contact Rating (Maximum per Pole)
NEMA Rating Designation Max Voltage A Continuous Carrying Current VA
Make Break Make Break
Q300 250 0.27 0.27 2.5 69 69
125 0.55 0.55 2.5 69 69
DC 13                              
  

Low Voltage DC

24V DC @ 1.1 Amps resistive load