Elf™

Click to enlarge - 440K-E330##_Product


Description

The Elf is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The Elf's unique miniature housing (only 75 x 25 x 29 mm (2.95 x 0.98 x 1.14 in.)) makes it the smallest interlock currently available. It is designed for smaller machines such as printers, copiers and domestic machinery which, until now, have been unable to use safety interlocks due to space restrictions. With its dual entry slots and rotatable head, the versatile Elf can offer up to eight different actuator entry options.

Operation of the switch is achieved through the insertion of a specially-profiled stainless-steel key that is permanently mounted to the guard door. The semi-flexible key allows the Elf to be used on small-radii doors (60 mm or 2.36 in.).

The Elf is available with a variety of contact configurations, conduit entry types and connectors. It is sealed to IP67 (watertight and dustproof). A blanking plug is supplied for the unused key entry.


Features


Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety
B10d: > 2 x 106 operations at min. load
PFHD: > 3 x10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives, cULus, TÜV, and CCC
Outputs
Safety Contacts T 
Direct Opening Action
1 N.C. 2 N.C.
Auxiliary Contacts 1 N.O. None
Thermal CurrentIlth 5 A (10 A if A600)
Rated Insulation Voltage 2500V
Switching Current @ Voltage, Min. 5 mA @ 5V DC
Utilization Category
A600/AC-15 (Ue) 600V 500V 240V 120V
  (le) 1.2 A 1.4 A 3.0 A 6.0 A
DC-13 (Ue) 24V      
  (le) 2 A      
Operating Characteristics
Break Contact Force, Min. 6 N (1.35 lbf)
Actuation Speed, Max. 160 mm (6.29 in.)/s
Actuation Frequency, Max. 2 cycles/s
Operating Radius, Min 150 mm (5.90 in.) [60 mm (2.36 in.) with GD2 kit, min.]
Operating Life @ 100 mA load 1 x 106 operations
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -20…+80° (-4…+176°)
Physical Characteristics
Housing Material UL Approved glass-filled PBT
Actuator Material Stainless Steel
Weight [g (oz)] 60 (2.11)
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years
T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started.

Product Selection

Contact Actuator Type Cat. No.
M16 Conduit Connector§ 
Safety Auxiliary Action M16 1/2 inch NPT Adaptor Connect to Distribution Box
4-Pin Micro (M12)
Connect to ArmorBlock Guard I/O
5-Pin Micro (M12) § 
1 N.C. 1 N.O. BBM Flat 440K-E33036 440K-E33029 440K-E33074
90° 440K-E33040 440K-E33030 440K-E33025
GD2 Metal alignment guide w/semi-flex actuator 440K-E33034 440K-E33031 440K-E33075
440K-E33014 440K-E33053 440K-E33076
2 N.C. Flat 440K-E33080 440K-E33037 440K-E33077 440K-E2NNFPS
90° 440K-E33041 440K-E33045 440K-E33024
GD2 Metal alignment guide w/semi-flex actuator 440K-E33046 440K-E33078 440K-E2NNAPS
440K-E33047 440K-E33079
  

§ For connector ratings see Safety Switches and Connectors.
§ With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.


Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays for 2 N.C. Contact Switch
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Single-Function Safety Relays for 1 N.C. & 1 N.O. Contact Switch
MSR9T 2 N.O. 1 N.C. Fixed Auto./Manual 24V AC/DC MSR9T 440R-F23027
MSR33RT 2 N.O. Solid State 1 N.O. Removable Auto. or Monitored Manual 24V DC SELV MSR33RT/RTP 440R-F23200
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
 

Note:  For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Connection Systems

Description Connection to Distribution Box
4-Pin Micro (M12)
Connection to ArmorBlock Guard I/O
5-Pin Micro (M12)
1 N.C. & 1 N.O. 2 N.C. 2 N.C.
Cordset 889D-F4AC-¬  889D-F4AC-¬ 
Patchcord 889D-F4ACDM-T  889D-F4ACDM-T  889D-F5ACDM-¬ 
Distribution Box 898D-P4‡ KT-DM4 898D-4‡ LT-DM4
Shorting Plug 898D-41KU-DM 898D-41LU-DM
T-Port 898D-43KY-D4 898D-43LY-D4
 

¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
‡ Replace symbol with 4 or 8 for number of ports.
Note:  For additional information, see Connection Systems.


Accessories

Description Dimensions Cat. No.
Click to enlarge - 440K_A21014 Actuator Flat actuator, not to be used with metal alignment guide Actuators¬  440K-A21014
Click to enlarge - 440K_A21006 Actuator 90° actuator, not to be used with metal alignment guide 440K-A21006
Click to enlarge - 440K_A21030 Guide Metal alignment guide with semi-flexible actuator 440K-A21030
Click to enlarge - 440K_A21069 Guide Metal Alignment Guide 440K-A21069
Click to enlarge - 440A-A33085_(Elf Cover Plate)_Accessories_3C Replacement Cover Replacement Covers 440A-A33085
Click to enlarge - 440K_A17180 Dust Cover_4C Dust Cover Dust Covers 440K-A17182
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440K-E330_Dims Rendered Click to enlarge - 440K-E330##_Dims
Note: 2D, 3D and electrical drawings are available on www.ab.com/.

Typical Wiring Diagrams

Description 1 N.C. & 1 N.O. 2 N.C.
Contact Configuration Click to enlarge - 440K-E330##_(1 NC & 1 NO)_Wiring Click to enlarge - 440K-E330##_(2 NC)_Wiring
Contact Action Click to enlarge - 440K-E330##_Contact_1NC1NO_BBM 02 Click to enlarge - 440K-E330##_Contact_2NC 02
Click to enlarge - ContactActionKey BBM
4-Pin Micro (M12) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out A (Safety) Click to enlarge - M12 D-Coded 4-Pin Male Pin-out B (Safety)
5-Pin Micro (M12)
For ArmorBlock Guard I/O
Click to enlarge - DC Micro (2-5)-Pin Male A_Pin-out (Safety)
Cordset
889D-F4AC-¬ 
Brown Safety A Safety A
Blue
White Aux A Safety B
Black
 
¬ Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths.