Cadet™ 3

Click to enlarge - 440K-C210##_Product


Description

The Cadet 3 is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. With its dual entry slots and rotatable head, the versatile Cadet 3 can offer up to eight different actuator entry options. The unique compact housing (90.5 x 31 x 30.4 mm (3.56 x 1.22 x 1.19 in.)) has industry standard DIN 50047 fixing centers for ease of mounting.

Operation of the switch is achieved through the insertion of a specially-profiled stainless-steel key that is permanently mounted to the guard door. A semi-flexible key allows the Cadet 3 to be used on small-radii doors (60 mm or 2.36 in.).

Available with a variety of contact configurations, the Cadet 3 is sealed to IP67. A blanking plug is supplied for the unused key entry.


Features


Specifications

Safety Ratings
Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1
Safety Classification Cat. 1 device per EN 954-1 dual channel interlocks suitable for Cat. 3 or 4 systems
Functional Safety Data ¬ 
Note: For up-to-date information, visit http://www.ab.com/safety
B10d: > 2 x 106 operations at min. load
PFHD: > 3 x10-7
MTTFd: > 385 years
Dual channel interlock may be suitable for performance levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics
Certifications CE Marked for all applicable directives, cULus, TÜV, and CCC
Outputs
Safety Contacts T 
Direct Opening Action
2 N.C. 3 N.C.
Auxiliary Contacts 1 N.O. None
Thermal CurrentIlth 10 A
Rated Insulation Voltage (Ui) 500V
Switching Current @ Voltage, Min. 5 mA @ 5V DC
Utilization Category
A600/AC-15 (Ue) 600V 500V 240V 120V
  (le) 1.2 A 1.4 A 3.0 A 6.0 A
DC-13 (Ue) 24V      
  (le) 2 A      
Operating Characteristics
Break Contact Force, Min. 15 N (3.37 lbf)
Actuation Speed, Max. 160 mm (6.29 in.)/s
Actuation Frequency, Max. 2 cycles/s
Operating Radius, Min 150 mm (5.90 in.) [60 mm (2.36 in.) with GD2 kit]
Operating Life @ 100 mA load 1 x 106 operations
Environmental
Enclosure Type Rating IP67
Operating Temperature [C (F)] -20…+ 80° (-4…+176°)
Physical Characteristics
Housing Material UL Approved glass-filled PBT
Actuator Material Stainless Steel
Weight [g (lb)] 80 (0.176)
Color Red
 
¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on:
- Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing
51840 operations per year
- Mission time/Proof test interval of 38 years
T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started.

Product Selection

Contact Actuator Type Cat. No.
Safety Auxiliary Action M16 Conduit Connector§ 
M16 1/2 inch NPT Adaptor Connect to Distribution Box
6-Pin Micro (M12)
Connect to ArmorBlock Guard I/O
5-Pin Micro (M12)§ 
3 N.C. Flat 440K-C21096 440K-C21048 440K-C21090 440K-C2NNFPS
90° 440K-C21097 440K-C21057 440K-C21091
GD2 Metal alignment guide w/semi-flex actuator 440K-C21062 440K-C21092 440K-C2NNAPS
440K-C21070
2 N.C. 1 N.O. BBM Flat 440K-C21098 440K-C21050 440K-C21054
90° 440K-C21061 440K-C21058 440K-C21067
GD2 Metal alignment guide w/semi-flex actuator 440K-C21074 440K-C21088
440K-C21055
MBB Flat 440K-C21052 440K-C21093 440K-C21060
90° 440K-C21065 440K-C21094 440K-C21068
GD2 Metal alignment guide w/semi-flex actuator 440K-C21095 440K-C21089
440K-C21080
 

§ For connector ratings see Typical Wiring Diagrams.
§ With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.


Recommended Logic Interfaces

Description Safety Outputs Auxiliary Outputs Terminals Reset Type Power Supply Cat. Page No. Cat. No.
Single-Function Safety Relays
MSR127RP 3 N.O. 1 N.C. Removable (Screw) Monitored Manual 24V AC/DC MSR127RP/TP 440R-N23135
MSR127TP 3 N.O. 1 N.C. Removable (Screw) Auto./Manual 24V AC/DC MSR127RP/TP 440R-N23132
MSR126T 2 N.O. None Fixed Auto./Manual 24V AC/DC MSR126R/T 440R-N23117
MSR30RT 2 N.O. Solid State 1 N.O. Solid State Removable Auto./Manual or Monitored Manual 24V DC MSR30RT/RTP 440R-N23198
Modular Safety Relays
MSR210P Base
2 N.C. only
2 N.O. 1 N.C. and 2 PNP Solid State Removable Auto./Manual or Monitored Manual 24V DC from the base unit MSR210P 440R-H23176
MSR220P Input Module Removable 24V DC MSR220P 440R-H23178
MSR310P Base MSR300 Series Output Modules 3 PNP Solid State Removable Auto./Manual Monitored Manual 24V DC MSR310P 440R-W23219
MSR320P Input Module 2 PNP Solid State Removable 24V DC from the base unit MSR320P 440R-W23218
  

Note:  For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.


Connection Systems

Description 6-Pin Micro (M12) 5-Pin Micro (M12)
Cordset 889R-F6ECA-¬ 
Patchcord 889R-F6ECRM-T  889D-F5ACDM-¬ 
Distribution Box 898R-P68MT-A5
Shorting Plug 898R-P61MU-RM
T-Port NA
 

¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
‡ Replace symbol with 4 or 8 for number of ports.
Note:  For additional information, see Safety Connection Systems.


Accessories

Description Dimensions Cat. No.
Click to enlarge - 440K_A21014 Actuator_GS Flat actuator, not to be used with metal alignment guide Actuators¬  (continued) 440K-A21014
Click to enlarge - 440K_A21006 Actuator_GS 90° actuator, not to be used with metal alignment guide 440K-A21006
Click to enlarge - 440K_A21030 ActGuide_GS Metal alignment guide with semi-flexible actuator 440K-A21030
Click to enlarge - 440A-A21115_(Cadet 3 Cover Plate)_Accessory_GS Replacement Cover 440A-A21115
Click to enlarge - 440K_A17182 Dust Cover_GS Dust Cover 440K-A17182
  

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Click to enlarge - 440K-C210##_Dims


Note: 2D, 3D and electrical drawings are available on www.ab.com.


Typical Wiring Diagrams

Description 2 N.C. & 1 N.O. 3 N.C.
Contact Configuration Click to enlarge - 440K-210## (2NC 1NO)_Wiring Click to enlarge - 440K-210## (3NC)_Wiring
Contact Action Click to enlarge - 440K-C210##_Contact_2NC1NO_BBM Click to enlarge - 440K-C210##_Contact_3NC
Click to enlarge - ContactActionKey Click to enlarge - 440K-C210##_Contact_2NC1NO_MBB
6-Pin Micro (M12) Click to enlarge - AC Micro 6-Pin Male B Pin-out (Safety) Click to enlarge - AC Micro 6-Pin Male Pin-out (Safety 3NC)
5-Pin Micro (M12) Click to enlarge - DC Micro (2-5)-Pin Male A_Pin-out (Safety)
Cordset
889R-F6ECA-¬ 
Red/White Safety A Safety A
Red/Black
Red Safety B Safety B
Red/Blue
Green Aux A Safety C
Red/Yellow
 
¬ Replace symbol with 2 (2 m), 5 (5 m) or 10 (10 m) for standard cable lengths.