Cadet™ 3
|
Description
The Cadet 3 is a tongue-operated (or key-operated) safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. With its dual entry slots and rotatable head, the versatile Cadet 3 can offer up to eight different actuator entry options. The unique compact housing (90.5 x 31 x 30.4 mm (3.56 x 1.22 x 1.19 in.)) has industry standard DIN 50047 fixing centers for ease of mounting.
Operation of the switch is achieved through the insertion of a specially-profiled stainless-steel key that is permanently mounted to the guard door. A semi-flexible key allows the Cadet 3 to be used on small-radii doors (60 mm or 2.36 in.).
Available with a variety of contact configurations, the Cadet 3 is sealed to IP67. A blanking plug is supplied for the unused key entry.
Features
- Compact size
- Ideal for small, lightweight guards
- Contacts, 2 N.C. and 1 N.O. or 3 N.C.
- Sealed to IP67
- Eight possible actuator entry points, easy to install
- Industry standard fixing centres to DIN 50047
- GD2 style available for demanding applications
Specifications
| Safety Ratings | |||||
| Standards | EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC/ EN60947-5-1, ANSI B11.19, AS4024.1 | ||||
| Safety Classification | Cat. 1 device per EN 954-1 dual channel interlocks suitable for Cat. 3 or 4 systems | ||||
| Functional Safety Data ¬ Note: For up-to-date information, visit http://www.ab.com/safety |
B10d: > 2 x 106 operations at min. load PFHD: > 3 x10-7 MTTFd: > 385 years Dual channel interlock may be suitable for performance levels Ple or Pld (according to ISO 13849-1:2006) and for use in SIL2 or SIL3 systems (according to IEC 62061) depending on application characteristics |
||||
| Certifications | CE Marked for all applicable directives, cULus, TÜV, and CCC | ||||
| Outputs | |||||
| Safety Contacts T Direct Opening Action |
2 N.C. | 3 N.C. | |||
| Auxiliary Contacts | 1 N.O. | None | |||
| Thermal CurrentIlth | 10 A | ||||
| Rated Insulation Voltage | (Ui) 500V | ||||
| Switching Current @ Voltage, Min. | 5 mA @ 5V DC | ||||
| Utilization Category | |||||
| A600/AC-15 | (Ue) | 600V | 500V | 240V | 120V |
| (le) | 1.2 A | 1.4 A | 3.0 A | 6.0 A | |
| DC-13 | (Ue) | 24V | |||
| (le) | 2 A | ||||
| Operating Characteristics | |||||
| Break Contact Force, Min. | 15 N (3.37 lbf) | ||||
| Actuation Speed, Max. | 160 mm (6.29 in.)/s | ||||
| Actuation Frequency, Max. | 2 cycles/s | ||||
| Operating Radius, Min | 150 mm (5.90 in.) [60 mm (2.36 in.) with GD2 kit] | ||||
| Operating Life @ 100 mA load | 1 x 106 operations | ||||
| Environmental | |||||
| Enclosure Type Rating | IP67 | ||||
| Operating Temperature [C (F)] | -20…+ 80° (-4…+176°) | ||||
| Physical Characteristics | |||||
| Housing Material | UL Approved glass-filled PBT | ||||
| Actuator Material | Stainless Steel | ||||
| Weight [g (lb)] | 80 (0.176) | ||||
| Color | Red | ||||
| ¬ Usable for ISO 13849-1:2006 and IEC 62061. Data other than B10d is based on: - Usage rate of 1op/10 mins., 24 hrs/day, 360 days/year, representing 51840 operations per year - Mission time/Proof test interval of 38 years T The safety contacts are described as normally closed (N.C.) i.e., with the guard closed, actuator in place (where relevant) and the machine able to be started. |
|||||
Product Selection
| Contact | Actuator Type | Cat. No. | |||||
| Safety | Auxiliary | Action | M16 Conduit | Connector§ | |||
| M16 | 1/2 inch NPT Adaptor | Connect to Distribution Box 6-Pin Micro (M12) |
Connect to ArmorBlock Guard I/O 5-Pin Micro (M12)§ |
||||
| 3 N.C. | — | — | Flat | 440K-C21096 | 440K-C21048 | 440K-C21090 | 440K-C2NNFPS |
| 90° | 440K-C21097 | 440K-C21057 | 440K-C21091 | — | |||
| GD2 Metal alignment guide w/semi-flex actuator | — | 440K-C21062 | 440K-C21092 | 440K-C2NNAPS | |||
| — | 440K-C21070 | — | — | — | |||
| 2 N.C. | 1 N.O. | BBM | Flat | 440K-C21098 | 440K-C21050 | 440K-C21054 | — |
| 90° | 440K-C21061 | 440K-C21058 | 440K-C21067 | — | |||
| GD2 Metal alignment guide w/semi-flex actuator | — | 440K-C21074 | 440K-C21088 | — | |||
| — | 440K-C21055 | — | — | — | |||
| MBB | Flat | 440K-C21052 | 440K-C21093 | 440K-C21060 | — | ||
| 90° | 440K-C21065 | 440K-C21094 | 440K-C21068 | — | |||
| GD2 Metal alignment guide w/semi-flex actuator | — | 440K-C21095 | 440K-C21089 | — | |||
| — | 440K-C21080 | — | — | — | |||
§ For connector ratings see Typical Wiring Diagrams.
§ With a 5-pin micro (M12) connector, not all contacts are connected. See Typical Wiring Diagrams for wiring details.
Recommended Logic Interfaces
| Description | Safety Outputs | Auxiliary Outputs | Terminals | Reset Type | Power Supply | Cat. Page No. | Cat. No. |
| Single-Function Safety Relays | |||||||
| MSR127RP | 3 N.O. | 1 N.C. | Removable (Screw) | Monitored Manual | 24V AC/DC | MSR127RP/TP | 440R-N23135 |
| MSR127TP | 3 N.O. | 1 N.C. | Removable (Screw) | Auto./Manual | 24V AC/DC | MSR127RP/TP | 440R-N23132 |
| MSR126T | 2 N.O. | None | Fixed | Auto./Manual | 24V AC/DC | MSR126R/T | 440R-N23117 |
| MSR30RT | 2 N.O. Solid State | 1 N.O. Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC | MSR30RT/RTP | 440R-N23198 |
| Modular Safety Relays | |||||||
| MSR210P Base 2 N.C. only |
2 N.O. | 1 N.C. and 2 PNP Solid State | Removable | Auto./Manual or Monitored Manual | 24V DC from the base unit | MSR210P | 440R-H23176 |
| MSR220P Input Module | — | — | Removable | — | 24V DC | MSR220P | 440R-H23178 |
| MSR310P Base | MSR300 Series Output Modules | 3 PNP Solid State | Removable | Auto./Manual Monitored Manual | 24V DC | MSR310P | 440R-W23219 |
| MSR320P Input Module | — | 2 PNP Solid State | Removable | — | 24V DC from the base unit | MSR320P | 440R-W23218 |
Note: For additional Safety Relays connectivity, see Safety Relays.
For additional Safety I/O and Safety PLC connectivity, see Programmable Safety Solutions.
For application and wiring diagrams, see Safety Applications and Wiring Diagrams.
Connection Systems
| Description | 6-Pin Micro (M12) | 5-Pin Micro (M12) |
| Cordset | 889R-F6ECA-¬ | — |
| Patchcord | 889R-F6ECRM-T | 889D-F5ACDM-¬ |
| Distribution Box | 898R-P68MT-A5 | — |
| Shorting Plug | 898R-P61MU-RM | — |
| T-Port | NA | — |
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
Replace symbol with 4 or 8 for number of ports.
Note: For additional information, see Safety Connection Systems.
Accessories
| Description | Dimensions | Cat. No. | |
|
Flat actuator, not to be used with metal alignment guide | Actuators¬ (continued) | 440K-A21014 |
|
|
90° actuator, not to be used with metal alignment guide | 440K-A21006 | |
|
Metal alignment guide with semi-flexible actuator | 440K-A21030 | |
|
|
Replacement Cover | — | 440A-A21115 |
|
Dust Cover | — | 440K-A17182 |
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
|
Note: 2D, 3D and electrical drawings are available on www.ab.com.
Typical Wiring Diagrams